Changes for page Siemens

Last modified by Joe on 2024/08/30 14:46

From version 40.1
edited by Theodore Xu
on 2023/09/15 11:58
Change comment: There is no comment for this version
To version 47.1
edited by Theodore Xu
on 2024/02/27 19:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -123,11 +123,11 @@
123 123  (% style="text-align:center" %)
124 124  [[image:以太网连接.png]]
125 125  
126 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==
126 +== **S7-300 Ethernet ** ==
127 127  
128 128  Supported Series: Siemens S7-300 series PLC
129 129  
130 -**1)V-BOX setting**
130 +**V-BOX setting**
131 131  
132 132  |**Items**|**Settings**|**Note**
133 133  |Protocol|Simens S7-300 Ethernet|
... ... @@ -135,7 +135,7 @@
135 135  |Port No.|102|
136 136  |PLC station No.|2|Need to be same as the PLC setting
137 137  
138 -**2)Address List**
138 +**Address List**
139 139  
140 140  |**Type**|**Device register**|**Format**|**Range**|**Note**
141 141  |(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7|
... ... @@ -171,41 +171,31 @@
171 171  |DBxDBW nndddd|0~~99999999
172 172  |DBxDBD nndddd|0~~99999999
173 173  
174 -**3)Configure the communication protocol**
174 +**Configure the communication protocol**
175 175  
176 -{{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
177 177  
178 -**4)Cable Wiring**
178 +**Cable Wiring**
179 179  
180 -{{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
181 181  
182 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==
182 +== **S7-1200 Ethernet ** ==
183 183  
184 184  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
185 185  
186 -== **S7-XXX Ethernet** ==
186 +**V-BOX Setting**
187 187  
188 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
189 -
190 -**1)V-BOX setting**
191 -
192 -|=**Items**|=**Settings**|=**Note**
193 -|Protocol|Siemens S7-XXX|
188 +|**Items**|**Settings**|**Note**
189 +|Protocol|Siemens S7-1200|
194 194  |Connection|Ethernet|
195 195  |Port No.|102|
196 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
197 -|HMI No.|Rack (Default as 0)|
192 +|PLC station No.|2|
198 198  
199 -Slot from TIA Portal is equal to Device No. of V-net
194 +(% style="text-align:center" %)
195 +[[image:西门子1200协议参数.png]]
200 200  
201 -Rack from TIA Portal is equal to HMI No. of V-net
197 +**Address List**
202 202  
203 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
204 -
205 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
206 -
207 -**2)Address List**
208 -
209 209  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
210 210  |(% rowspan="4" %)Bit|I|I|M d.o|(((
211 211  d:0~-~-9999
... ... @@ -284,18 +284,176 @@
284 284  Address value is a multiple of 4
285 285  )))
286 286  
287 -**3)Configure the communication protocol**
277 +{{info}}
278 +✎Note:
288 288  
289 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
280 +* The S7-1200 supports simultaneous connection of three devices.
281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address.
283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display
284 +{{/info}}
290 290  
286 +**PLC Settings**
287 +
288 +Add BD
289 +
290 +* Please uncheck [Symbolic access only] option;
291 +
292 +(% style="text-align:center" %)
293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]]
294 +
295 +Address settings, using BD2 as example.
296 +
297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
298 +* 2 represent DB block number
299 +* xxxx represent address
300 +
301 +**Such as:**
302 +
303 +* DBxDBB20000 = DB2.DBB0
304 +* DBxDBW20004 = DB2.DBW4
305 +
306 +(% style="text-align:center" %)
307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]]
308 +
309 +**How to connect with S7-1200 Firmware V4.0**
310 +
311 +PLC configuration
312 +
313 +* Double click [device configuration] in Siemens via software
314 +* Double click [protection] to enter protection configuration screen
315 +
316 +(% style="text-align:center" %)
317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]]
318 +
319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
320 +
321 +(% style="text-align:center" %)
322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]]
323 +
324 +DB settings
325 +
326 +* Right click [DB], select [properties]
327 +* Uncheck [optimized block access]
328 +
329 +**Cable Wiring**
330 +
331 +(% style="text-align:center" %)
332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]]
333 +
334 +== **S7-XXX Ethernet** ==
335 +
336 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
337 +
338 +**V-BOX setting**
339 +
340 +|=**Items**|=**Settings**|=**Note**
341 +|Protocol|Siemens S7-XXX|
342 +|Connection|Ethernet|
343 +|Port No.|102|
344 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
345 +|HMI No.|Rack (Default as 0)|
346 +
347 +Slot from TIA Portal is equal to Device No. of V-net
348 +
349 +Rack from TIA Portal is equal to HMI No. of V-net
350 +
351 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
352 +
353 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
354 +
355 +**Address List**
356 +
357 +|**Type**|**Device register**|**Format**|**Range**|**Note**
358 +|(% rowspan="4" %)Bit|I|M d.o|(((
359 +d:0~-~-9999
360 +
361 +o:0-7
362 +)))|
363 +|Q|Q d.o|(((
364 +d:0~-~-9999
365 +
366 +o:0-7
367 +)))|
368 +|M|M d.o|(((
369 +d:0~-~-9999
370 +
371 +o:0-7
372 +)))|
373 +|DB0.DB-DB99.DB|DBxDBnndddd.o|(((
374 +nn:0-9999,
375 +
376 +dddd:0-9999,
377 +
378 +o:0-7
379 +)))|(((
380 +nn:DB No.
381 +
382 +dddd:address value
383 +
384 +o: digit address
385 +)))
386 +|(% rowspan="8" %)Word|M|MB d|d:0-99999|
387 +|M|MW d|d:0-99999|(((
388 +MW0=MB(0~~1)
389 +
390 +MW2=MB(2~~3)
391 +
392 +Address value is a multiple of 2
393 +)))
394 +|M|MD d|d:0-99999|(((
395 +MD0=MB(0~~3)
396 +
397 +MD4=MB(4~~7)
398 +
399 +Address value is a multiple of 4
400 +)))
401 +|I|IW d|d:0-99999|
402 +|Q|QW d|d:0-99999|
403 +|DB0.DB-DB99.DB|DBxDBBnndddd|(((
404 +nn:0-9999
405 +
406 +dddd:0-9999
407 +)))|(((
408 +nn:DB No.
409 +
410 +dddd:address value
411 +)))
412 +|DB0.DB-DB99.DB|DBxDBWnndddd|(((
413 +nn:0-9999
414 +
415 +dddd:0-9999
416 +)))|(((
417 +nn:DB No.
418 +
419 +dddd:address value
420 +
421 +Address value is a multiple of 2
422 +)))
423 +|DB0.DB-DB99.DB|DBxDBDnndddd|(((
424 +nn:0-9999
425 +
426 +dddd:0-9999
427 +)))|(((
428 +nn:DB No.
429 +
430 +dddd:address value
431 +
432 +Address value is a multiple of 4
433 +)))
434 +
435 +**Configure the communication protocol**
436 +
437 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
438 +
291 291  **✎Note:**
292 292  
293 293  * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
294 294  * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
295 295  
296 -**4)Cable Wiring**
444 +**Cable Wiring**
297 297  
298 -{{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
446 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
299 299  
300 300  == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** ==
301 301  
... ... @@ -332,30 +332,28 @@
332 332  
333 333  Click [Tools]~-~-[Ethernet Connections],shown as below.
334 334  
335 -{{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]
483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]
336 336  
337 337  Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
338 338  
339 -{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]
487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]
340 340  
341 341  **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
342 342  
343 -{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]
491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]
344 344  
345 345   **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
346 346  
347 -{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]
495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]
348 348  
349 349  **V-BOX Communication Settings**
350 350  
351 351  Set PLC IP in [IP Address] settings;
352 352  
353 -{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]]
501 +(% style="text-align:center" %)
502 +[[image:V-NET_Client logo8.png]]
354 354  
355 -Enable V-BOX Ethernet in [Network];
356 356  
357 -{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]]
358 -
359 359  TSAP setting
360 360  
361 361  * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
1697099618537-157.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.4 KB
Content
V-NET_Client logo8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +22.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +82.1 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +133.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +96.9 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
西门子1200协议参数.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +64.6 KB
Content