From version 41.1
edited by Theodore Xu
on 2023/09/15 11:58
on 2023/09/15 11:58
Change comment:
There is no comment for this version
To version 38.1
edited by Theodore Xu
on 2023/09/15 11:57
on 2023/09/15 11:57
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,21 +17,21 @@ 17 17 18 18 **Address List ** 19 19 20 -|**Type**|**Device register**|**Format**|**Range**|**Note** 21 -|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 -|Q|Q ddddd.o|0.0~~99999.7| 23 -|V|VWbit ddddd.o|0.0~~99999.7| 24 -|V|V ddddd.o|0.0~~99999.7| 25 -|M|M ddddd.o|0.0~~99999.7| 26 -|SM|ddddd.o|0.0~~99999.7| 27 -|S|ddddd.o|0.0~~99999.7|Read only 28 -|T|ddddd|0~~99999|Timer state, read only 29 -|C|ddddd|0~~99999|Counter state, read only 30 -|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 -|Q|QW ddddd|0~~99999| 32 -|AI|AIW ddddd|0~~99999| 33 -|AQ|VB ddddd|0~~99999| 34 -|V|VW ddddd|0~~99998|((( 20 +|**Type**|**Device register**|**V-Box register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V|V ddddd.o|0.0~~99999.7| 25 +|M|M|M ddddd.o|0.0~~99999.7| 26 +|SM|SM|ddddd.o|0.0~~99999.7| 27 +|S|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|T|ddddd|0~~99999|Timer state, read only 29 +|C|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999| 31 +|Q|QW|QW ddddd|0~~99999| 32 +|AI|AIW|AIW ddddd|0~~99999| 33 +|AQ|VB|VB ddddd|0~~99999| 34 +|V|VW|VW ddddd|0~~99998|((( 35 35 VW0=VB (0~~1) 36 36 37 37 VW2=VB (2~~3) ... ... @@ -38,7 +38,7 @@ 38 38 39 39 Address value is a multiple of 2 40 40 ))) 41 -|V|VD ddddd|0~~99998|((( 41 +|V|VD|VD ddddd|0~~99998|((( 42 42 VD0=VB (0~~3) 43 43 44 44 VD2=VB (4~~7) ... ... @@ -45,8 +45,8 @@ 45 45 46 46 Address value is a multiple of 4 47 47 ))) 48 -|M|MB ddddd|0~~99999| 49 -|M|MW ddddd|0~~99999|((( 48 +|M|MB|MB ddddd|0~~99999| 49 +|M|MW|MW ddddd|0~~99999|((( 50 50 MW0=MB(0~~1) 51 51 52 52 MW2=MB(2~~3) ... ... @@ -53,7 +53,7 @@ 53 53 54 54 Address value is a multiple of 2 55 55 ))) 56 -|M|MD ddddd|0~~99999|((( 56 +|M|MD|MD ddddd|0~~99999|((( 57 57 MD0=MB(0~~3) 58 58 59 59 MD4=MB(4~~7) ... ... @@ -60,9 +60,9 @@ 60 60 61 61 Address value is a multiple of 4 62 62 ))) 63 -|T|TW ddddd|0~~99999|Value of timer 64 -|C|CW ddddd|0~~99999|Value of counter 65 -|W|SW ddddd|0~~99999| 63 +|T|TW|TW ddddd|0~~99999|Value of timer 64 +|C|CW|CW ddddd|0~~99999|Value of counter 65 +|W|SW|SW ddddd|0~~99999| 66 66 67 67 **PLC setting** 68 68 ... ... @@ -123,11 +123,11 @@ 123 123 (% style="text-align:center" %) 124 124 [[image:以太网连接.png]] 125 125 126 -== **S7-300 Ethernet ** == 126 +== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** == 127 127 128 128 Supported Series: Siemens S7-300 series PLC 129 129 130 -**V-BOX setting** 130 +**1)V-BOX setting** 131 131 132 132 |**Items**|**Settings**|**Note** 133 133 |Protocol|Simens S7-300 Ethernet| ... ... @@ -135,21 +135,21 @@ 135 135 |Port No.|102| 136 136 |PLC station No.|2|Need to be same as the PLC setting 137 137 138 -**Address List** 138 +**2)Address List** 139 139 140 -|**Type**|**Device register**|**Format**|**Range**|**Note** 141 -|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 -|Q|Q ddddd.o|0.0~~99999.7| 143 -|M|M ddddd.o|0.0~~99999.7| 144 -|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 140 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 145 145 nn: block number; 146 146 147 147 dddd: address; 148 148 ))) 149 -|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 -|Q|QW ddddd|0~~99999| 151 -|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 -|MW ddddd|0~~99999|((( 149 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 150 +|Q|QW|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 152 +|MW|MW ddddd|0~~99999|((( 153 153 MW0=MB(0~~1) 154 154 155 155 MW2=MB(2~~3) ... ... @@ -156,7 +156,7 @@ 156 156 157 157 Address value is a multiple of 2 158 158 ))) 159 -|MD ddddd|0~~99999|((( 159 +|MD|MD ddddd|0~~99999|((( 160 160 MD0=MB(0~~3) 161 161 162 162 MD4=MB(4~~7) ... ... @@ -163,21 +163,21 @@ 163 163 164 164 Address value is a multiple of 4 165 165 ))) 166 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 167 167 nn: block number; 168 168 169 169 dddd: address 170 170 ))) 171 -|DBxDBW nndddd|0~~99999999 172 -|DBxDBD nndddd|0~~99999999 171 +|DBxDBW|DBxDBW nndddd|0~~99999999 172 +|DBxDBD|DBxDBD nndddd|0~~99999999 173 173 174 -**Configure the communication protocol** 174 +**3)Configure the communication protocol** 175 175 176 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 176 +{{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 177 177 178 -**Cable Wiring** 178 +**4)Cable Wiring** 179 179 180 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 180 +{{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 181 181 182 182 == {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** == 183 183