From version 44.1
edited by Theodore Xu
on 2023/10/12 16:32
on 2023/10/12 16:32
Change comment:
There is no comment for this version
To version 42.1
edited by Theodore Xu
on 2023/09/15 11:59
on 2023/09/15 11:59
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -187,7 +187,7 @@ 187 187 188 188 Supported Series: Siemens S7-400, S7-1200 and S7-1500 189 189 190 -**V-BOX setting** 190 +**1)V-BOX setting** 191 191 192 192 |=**Items**|=**Settings**|=**Note** 193 193 |Protocol|Siemens S7-XXX| ... ... @@ -200,11 +200,11 @@ 200 200 201 201 Rack from TIA Portal is equal to HMI No. of V-net 202 202 203 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 203 +{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 204 204 205 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 205 +{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 206 206 207 -**Address List** 207 +**2)Address List** 208 208 209 209 |**Type**|**Device register**|**Format**|**Range**|**Note** 210 210 |(% rowspan="4" %)Bit|I|M d.o|((( ... ... @@ -284,9 +284,9 @@ 284 284 Address value is a multiple of 4 285 285 ))) 286 286 287 -**Configure the communication protocol** 287 +**3)Configure the communication protocol** 288 288 289 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 289 +{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 290 290 291 291 **✎Note:** 292 292 ... ... @@ -293,9 +293,9 @@ 293 293 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 294 294 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 295 295 296 -**Cable Wiring** 296 +**4)Cable Wiring** 297 297 298 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 298 +{{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 299 299 300 300 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 301 301