From version 44.1
edited by Theodore Xu
on 2023/10/12 16:32
on 2023/10/12 16:32
Change comment:
There is no comment for this version
To version 45.1
edited by Theodore Xu
on 2023/10/12 16:37
on 2023/10/12 16:37
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -179,10 +179,102 @@ 179 179 180 180 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 181 181 182 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 183 183 184 184 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 185 185 186 +**V-BOX Setting** 187 + 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 190 +|Connection|Ethernet| 191 +|Port No.|102| 192 +|PLC station No.|2| 193 + 194 +**Address List** 195 + 196 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 197 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 198 +d:0~-~-9999 199 + 200 +o:0-7 201 +)))| 202 +|Q|Q|Q d.o|((( 203 +d:0~-~-9999 204 + 205 +o:0-7 206 +)))| 207 +|M|M|M d.o|((( 208 +d:0~-~-9999 209 + 210 +o:0-7 211 +)))| 212 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 213 +nn:0-9999, 214 + 215 +dddd:0-9999, 216 + 217 +o:0-7 218 +)))|((( 219 +nn:DB No. 220 + 221 +dddd:address value 222 + 223 +o: digit address 224 +))) 225 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 226 +|M|MW|MW d|d:0-99999|((( 227 +MW0=MB(0~~1) 228 + 229 +MW2=MB(2~~3) 230 + 231 +Address value is a multiple of 2 232 +))) 233 +|M|MD|MD d|d:0-99999|((( 234 +MD0=MB(0~~3) 235 + 236 +MD4=MB(4~~7) 237 + 238 +Address value is a multiple of 4 239 +))) 240 +|I|IW|IW d|d:0-99999| 241 +|Q|QW|QW d|d:0-99999| 242 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 243 +nn:0-9999 244 + 245 +dddd:0-9999 246 +)))|((( 247 +nn:DB No. 248 + 249 +dddd:address value 250 +))) 251 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 252 +nn:0-9999 253 + 254 +dddd:0-9999 255 +)))|((( 256 +nn:DB No. 257 + 258 +dddd:address value 259 + 260 +Address value is a multiple of 2 261 +))) 262 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 263 +nn:0-9999 264 + 265 +dddd:0-9999 266 +)))|((( 267 +nn:DB No. 268 + 269 +dddd:address value 270 + 271 +Address value is a multiple of 4 272 +))) 273 + 274 +**Communication Settings** 275 + 276 +Enable HMI Ethernet in [Project Settings] 277 + 186 186 == **S7-XXX Ethernet** == 187 187 188 188 Supported Series: Siemens S7-400, S7-1200 and S7-1500
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content