From version 44.1
edited by Theodore Xu
on 2023/10/12 16:32
on 2023/10/12 16:32
Change comment:
There is no comment for this version
To version 47.1
edited by Theodore Xu
on 2024/02/27 19:56
on 2024/02/27 19:56
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
- 1697099618537-157.png
- V-NET_Client logo8.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- 西门子1200协议参数.png
Details
- Page properties
-
- Content
-
... ... @@ -179,10 +179,158 @@ 179 179 180 180 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 181 181 182 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 183 183 184 184 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 185 185 186 +**V-BOX Setting** 187 + 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 190 +|Connection|Ethernet| 191 +|Port No.|102| 192 +|PLC station No.|2| 193 + 194 +(% style="text-align:center" %) 195 +[[image:西门子1200协议参数.png]] 196 + 197 +**Address List** 198 + 199 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 200 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 201 +d:0~-~-9999 202 + 203 +o:0-7 204 +)))| 205 +|Q|Q|Q d.o|((( 206 +d:0~-~-9999 207 + 208 +o:0-7 209 +)))| 210 +|M|M|M d.o|((( 211 +d:0~-~-9999 212 + 213 +o:0-7 214 +)))| 215 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 216 +nn:0-9999, 217 + 218 +dddd:0-9999, 219 + 220 +o:0-7 221 +)))|((( 222 +nn:DB No. 223 + 224 +dddd:address value 225 + 226 +o: digit address 227 +))) 228 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 229 +|M|MW|MW d|d:0-99999|((( 230 +MW0=MB(0~~1) 231 + 232 +MW2=MB(2~~3) 233 + 234 +Address value is a multiple of 2 235 +))) 236 +|M|MD|MD d|d:0-99999|((( 237 +MD0=MB(0~~3) 238 + 239 +MD4=MB(4~~7) 240 + 241 +Address value is a multiple of 4 242 +))) 243 +|I|IW|IW d|d:0-99999| 244 +|Q|QW|QW d|d:0-99999| 245 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 246 +nn:0-9999 247 + 248 +dddd:0-9999 249 +)))|((( 250 +nn:DB No. 251 + 252 +dddd:address value 253 +))) 254 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 255 +nn:0-9999 256 + 257 +dddd:0-9999 258 +)))|((( 259 +nn:DB No. 260 + 261 +dddd:address value 262 + 263 +Address value is a multiple of 2 264 +))) 265 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 266 +nn:0-9999 267 + 268 +dddd:0-9999 269 +)))|((( 270 +nn:DB No. 271 + 272 +dddd:address value 273 + 274 +Address value is a multiple of 4 275 +))) 276 + 277 +{{info}} 278 +✎Note: 279 + 280 +* The S7-1200 supports simultaneous connection of three devices. 281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display 284 +{{/info}} 285 + 286 +**PLC Settings** 287 + 288 +Add BD 289 + 290 +* Please uncheck [Symbolic access only] option; 291 + 292 +(% style="text-align:center" %) 293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 294 + 295 +Address settings, using BD2 as example. 296 + 297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 298 +* 2 represent DB block number 299 +* xxxx represent address 300 + 301 +**Such as:** 302 + 303 +* DBxDBB20000 = DB2.DBB0 304 +* DBxDBW20004 = DB2.DBW4 305 + 306 +(% style="text-align:center" %) 307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 308 + 309 +**How to connect with S7-1200 Firmware V4.0** 310 + 311 +PLC configuration 312 + 313 +* Double click [device configuration] in Siemens via software 314 +* Double click [protection] to enter protection configuration screen 315 + 316 +(% style="text-align:center" %) 317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 318 + 319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 320 + 321 +(% style="text-align:center" %) 322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 323 + 324 +DB settings 325 + 326 +* Right click [DB], select [properties] 327 +* Uncheck [optimized block access] 328 + 329 +**Cable Wiring** 330 + 331 +(% style="text-align:center" %) 332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 333 + 186 186 == **S7-XXX Ethernet** == 187 187 188 188 Supported Series: Siemens S7-400, S7-1200 and S7-1500 ... ... @@ -332,30 +332,28 @@ 332 332 333 333 Click [Tools]~-~-[Ethernet Connections],shown as below. 334 334 335 - {{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 336 336 337 337 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 338 338 339 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 340 340 341 341 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 342 342 343 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 344 344 345 345 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 346 346 347 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 348 348 349 349 **V-BOX Communication Settings** 350 350 351 351 Set PLC IP in [IP Address] settings; 352 352 353 -{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]] 501 +(% style="text-align:center" %) 502 +[[image:V-NET_Client logo8.png]] 354 354 355 -Enable V-BOX Ethernet in [Network]; 356 356 357 -{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]] 358 - 359 359 TSAP setting 360 360 361 361 * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- V-NET_Client logo8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content