1 -== **S7-200 Smart Serial** ==
1 += {{id name="HSiemens"/}}**Siemens ** =
2 2  
3 -**V-BOX setting**
3 +== **S7-200 Smart Ethernet ** ==
4 4  
5 -(% style="width:1323.87px" %)
6 -|**Items**|**Settings**|**Note**
7 -|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI|
8 -|Connection|(% style="width:783px" %)RS485|
9 -|Baud rate|(% style="width:783px" %)9600|
10 -|Data bit|(% style="width:783px" %)8|
11 -|Parity|(% style="width:783px" %)EVEN|
12 -|Stop bit|(% style="width:783px" %)1|
13 -|PLC station No.|(% style="width:783px" %)2|
5 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
14 14  
15 -(% style="text-align:center" %)
16 -[[image:西门子200串口.png]]
7 +**1)PLC software**
17 17  
18 -**Address List **
19 -
20 -|**Type**|**Device register**|**Format**|**Range**|**Note**
21 -|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7|
22 -|Q|Q ddddd.o|0.0~~99999.7|
23 -|V|VWbit ddddd.o|0.0~~99999.7|
24 -|V|V ddddd.o|0.0~~99999.7|
25 -|M|M ddddd.o|0.0~~99999.7|
26 -|SM|ddddd.o|0.0~~99999.7|
27 -|S|ddddd.o|0.0~~99999.7|Read only
28 -|T|ddddd|0~~99999|Timer state, read only
29 -|C|ddddd|0~~99999|Counter state, read only
30 -|(% rowspan="12" %)Word|I|IW ddddd|0~~99999|
31 -|Q|QW ddddd|0~~99999|
32 -|AI|AIW ddddd|0~~99999|
33 -|AQ|VB ddddd|0~~99999|
34 -|V|VW ddddd|0~~99998|(((
35 -VW0=VB (0~~1)
36 -
37 -VW2=VB (2~~3)
38 -
39 -Address value is a multiple of 2
40 -)))
41 -|V|VD ddddd|0~~99998|(((
42 -VD0=VB (0~~3)
43 -
44 -VD2=VB (4~~7)
45 -
46 -Address value is a multiple of 4
47 -)))
48 -|M|MB ddddd|0~~99999|
49 -|M|MW ddddd|0~~99999|(((
50 -MW0=MB(0~~1)
51 -
52 -MW2=MB(2~~3)
53 -
54 -Address value is a multiple of 2
55 -)))
56 -|M|MD ddddd|0~~99999|(((
57 -MD0=MB(0~~3)
58 -
59 -MD4=MB(4~~7)
60 -
61 -Address value is a multiple of 4
62 -)))
63 -|T|TW ddddd|0~~99999|Value of timer
64 -|C|CW ddddd|0~~99999|Value of counter
65 -|W|SW ddddd|0~~99999|
66 -
67 -**PLC setting**
68 -
69 69  (% style="text-align:center" %)
70 70  [[image:西门子软件版本.png]]
71 71  
12 +**2)Ethernet Configuration**
13 +
72 72  (% style="text-align:center" %)
73 -[[image:485通讯配置.png]]
15 +[[image:以太网通讯配置.png]]
74 74  
75 -**Connect and Download**
17 +**3)Connect PC software**
76 76  
77 77  (% style="text-align:center" %)
78 -[[image:以太网 PC和PLC连接.png]]
79 -
80 -(% style="text-align:center" %)
81 81  [[image:以太网下载.png]]
82 82  
83 -**Cable Wiring**
22 +**4)Configure of V-net**
84 84  
85 85  (% style="text-align:center" %)
86 -[[image:485接线.png]]
87 -
88 -== **S7-200 Smart Ethernet ** ==
89 -
90 -**V-BOX setting**
91 -
92 -|**Items**|**Settings**
93 -|Protocol|Siemens S7-200 Smart(Ethernet)
94 -|Connection|Ethernet
95 -|Port No.|102
96 -|PLC station No.|2
97 -
98 -(% style="text-align:center" %)
99 99  [[image:西门子200smart 以太网.png]]
100 100  
101 -**PLC setting**
27 +**5)wiring**
102 102  
103 -(% style="text-align:center" %)
104 -[[image:西门子软件版本.png]]
105 105  
106 -(% style="text-align:center" %)
107 -[[image:以太网通讯配置.png]]
108 -
109 -**Connect and Download**
110 -
111 -(% style="text-align:center" %)
112 -[[image:以太网 PC和PLC连接.png]]
113 -
114 -(% style="text-align:center" %)
115 -[[image:以太网下载.png]]
116 -
117 -**Cable Wiring**
118 -
119 119  V-Box : RJ45 Ethernet interface
120 120  
121 121  PLC : RJ45 Ethernet interface
... ... @@ -123,11 +123,13 @@
123 123  (% style="text-align:center" %)
124 124  [[image:以太网连接.png]]
125 125  
126 -== **S7-300 Ethernet ** ==
37 +
127 127  
39 +== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==
40 +
128 128  Supported Series: Siemens S7-300 series PLC
129 129  
130 -**V-BOX setting**
43 +**1)V-BOX setting**
131 131  
132 132  |**Items**|**Settings**|**Note**
133 133  |Protocol|Simens S7-300 Ethernet|
... ... @@ -135,21 +135,21 @@
135 135  |Port No.|102|
136 136  |PLC station No.|2|Need to be same as the PLC setting
137 137  
138 -**Address List**
51 +**2)Address List**
139 139  
140 -|**Type**|**Device register**|**Format**|**Range**|**Note**
141 -|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7|
142 -|Q|Q ddddd.o|0.0~~99999.7|
143 -|M|M ddddd.o|0.0~~99999.7|
144 -|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|(((
53 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
54 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
55 +|Q|Q|Q ddddd.o|0.0~~99999.7|
56 +|M|M|M ddddd.o|0.0~~99999.7|
57 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
145 145  nn: block number;
146 146  
147 147  dddd: address;
148 148  )))
149 -|(% rowspan="8" %)Word|I|IW ddddd|0~~99999|
150 -|Q|QW ddddd|0~~99999|
151 -|(% rowspan="3" %)M|MB ddddd|0~~99999|
152 -|MW ddddd|0~~99999|(((
62 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
63 +|Q|QW|QW ddddd|0~~99999|
64 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
65 +|MW|MW ddddd|0~~99999|(((
153 153  MW0=MB(0~~1)
154 154  
155 155  MW2=MB(2~~3)
... ... @@ -156,7 +156,7 @@
156 156  
157 157  Address value is a multiple of 2
158 158  )))
159 -|MD ddddd|0~~99999|(((
72 +|MD|MD ddddd|0~~99999|(((
160 160  MD0=MB(0~~3)
161 161  
162 162  MD4=MB(4~~7)
... ... @@ -163,36 +163,49 @@
163 163  
164 164  Address value is a multiple of 4
165 165  )))
166 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
79 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
167 167  nn: block number;
168 168  
169 169  dddd: address
170 170  )))
171 -|DBxDBW nndddd|0~~99999999
172 -|DBxDBD nndddd|0~~99999999
84 +|DBxDBW|DBxDBW nndddd|0~~99999999
85 +|DBxDBD|DBxDBD nndddd|0~~99999999
173 173  
174 -**Configure the communication protocol**
87 +**3)Configure the communication protocol**
175 175  
176 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
89 +{{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
177 177  
178 -**Cable Wiring**
91 +**4)Cable Wiring**
179 179  
180 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
93 +{{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
181 181  
182 -== **S7-1200 Ethernet ** ==
95 +== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==
183 183  
184 184  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
185 185  
186 -**V-BOX Setting**
99 +== {{id name="HS7-XXXEthernetl"/}}**S7-XXX Ethernet l** ==
187 187  
188 -|**Items**|**Settings**|**Note**
189 -|Protocol|Siemens S7-1200|
101 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
102 +
103 +**1)V-BOX setting**
104 +
105 +|=**Items**|=**Settings**|=**Note**
106 +|Protocol|Siemens S7-XXX|
190 190  |Connection|Ethernet|
191 191  |Port No.|102|
192 -|PLC station No.|2|
109 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
110 +|HMI No.|Rack (Default as 0)|
193 193  
194 -**Address List**
112 +Slot from TIA Portal is equal to Device No. of V-net
195 195  
114 +Rack from TIA Portal is equal to HMI No. of V-net
115 +
116 +{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
117 +
118 +{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
119 +
120 +**2)Address List**
121 +
196 196  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
197 197  |(% rowspan="4" %)Bit|I|I|M d.o|(((
198 198  d:0~-~-9999
... ... @@ -271,123 +271,18 @@
271 271  Address value is a multiple of 4
272 272  )))
273 273  
274 -**Communication Settings**
200 +**3)Configure the communication protocol**
275 275  
276 -Enable HMI Ethernet in [Project Settings]
202 +{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
277 277  
278 -== **S7-XXX Ethernet** ==
279 -
280 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
281 -
282 -**V-BOX setting**
283 -
284 -|=**Items**|=**Settings**|=**Note**
285 -|Protocol|Siemens S7-XXX|
286 -|Connection|Ethernet|
287 -|Port No.|102|
288 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
289 -|HMI No.|Rack (Default as 0)|
290 -
291 -Slot from TIA Portal is equal to Device No. of V-net
292 -
293 -Rack from TIA Portal is equal to HMI No. of V-net
294 -
295 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
296 -
297 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
298 -
299 -**Address List**
300 -
301 -|**Type**|**Device register**|**Format**|**Range**|**Note**
302 -|(% rowspan="4" %)Bit|I|M d.o|(((
303 -d:0~-~-9999
304 -
305 -o:0-7
306 -)))|
307 -|Q|Q d.o|(((
308 -d:0~-~-9999
309 -
310 -o:0-7
311 -)))|
312 -|M|M d.o|(((
313 -d:0~-~-9999
314 -
315 -o:0-7
316 -)))|
317 -|DB0.DB-DB99.DB|DBxDBnndddd.o|(((
318 -nn:0-9999,
319 -
320 -dddd:0-9999,
321 -
322 -o:0-7
323 -)))|(((
324 -nn:DB No.
325 -
326 -dddd:address value
327 -
328 -o: digit address
329 -)))
330 -|(% rowspan="8" %)Word|M|MB d|d:0-99999|
331 -|M|MW d|d:0-99999|(((
332 -MW0=MB(0~~1)
333 -
334 -MW2=MB(2~~3)
335 -
336 -Address value is a multiple of 2
337 -)))
338 -|M|MD d|d:0-99999|(((
339 -MD0=MB(0~~3)
340 -
341 -MD4=MB(4~~7)
342 -
343 -Address value is a multiple of 4
344 -)))
345 -|I|IW d|d:0-99999|
346 -|Q|QW d|d:0-99999|
347 -|DB0.DB-DB99.DB|DBxDBBnndddd|(((
348 -nn:0-9999
349 -
350 -dddd:0-9999
351 -)))|(((
352 -nn:DB No.
353 -
354 -dddd:address value
355 -)))
356 -|DB0.DB-DB99.DB|DBxDBWnndddd|(((
357 -nn:0-9999
358 -
359 -dddd:0-9999
360 -)))|(((
361 -nn:DB No.
362 -
363 -dddd:address value
364 -
365 -Address value is a multiple of 2
366 -)))
367 -|DB0.DB-DB99.DB|DBxDBDnndddd|(((
368 -nn:0-9999
369 -
370 -dddd:0-9999
371 -)))|(((
372 -nn:DB No.
373 -
374 -dddd:address value
375 -
376 -Address value is a multiple of 4
377 -)))
378 -
379 -**Configure the communication protocol**
380 -
381 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
382 -
383 383  **✎Note:**
384 384  
385 385  * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
386 386  * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
387 387  
388 -**Cable Wiring**
209 +**4)Cable Wiring**
389 389  
390 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
211 +{{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
391 391  
392 392  == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** ==
393 393  
... ... @@ -455,7 +455,7 @@
455 455  **function** **init**.main()
456 456   addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address//
457 457   addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address//
458 -**end**
279 + **end**
459 459  
460 460  Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
461 461  
1697099618537-157.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -36.4 KB
Content
485接线.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -242.2 KB
Content
485通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -154.4 KB
Content
以太网 PC和PLC连接.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -131.3 KB
Content
西门子200串口.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.5 KB
Content