From version 45.1
edited by Theodore Xu
on 2023/10/12 16:37
on 2023/10/12 16:37
Change comment:
There is no comment for this version
To version 42.1
edited by Theodore Xu
on 2023/09/15 11:59
on 2023/09/15 11:59
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -179,107 +179,15 @@ 179 179 180 180 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 181 181 182 -== **S7-1200 Ethernet ** == 182 +== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** == 183 183 184 184 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 185 185 186 -**V-BOX Setting** 187 - 188 -|**Items**|**Settings**|**Note** 189 -|Protocol|Siemens S7-1200| 190 -|Connection|Ethernet| 191 -|Port No.|102| 192 -|PLC station No.|2| 193 - 194 -**Address List** 195 - 196 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 197 -|(% rowspan="4" %)Bit|I|I|M d.o|((( 198 -d:0~-~-9999 199 - 200 -o:0-7 201 -)))| 202 -|Q|Q|Q d.o|((( 203 -d:0~-~-9999 204 - 205 -o:0-7 206 -)))| 207 -|M|M|M d.o|((( 208 -d:0~-~-9999 209 - 210 -o:0-7 211 -)))| 212 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 213 -nn:0-9999, 214 - 215 -dddd:0-9999, 216 - 217 -o:0-7 218 -)))|((( 219 -nn:DB No. 220 - 221 -dddd:address value 222 - 223 -o: digit address 224 -))) 225 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 226 -|M|MW|MW d|d:0-99999|((( 227 -MW0=MB(0~~1) 228 - 229 -MW2=MB(2~~3) 230 - 231 -Address value is a multiple of 2 232 -))) 233 -|M|MD|MD d|d:0-99999|((( 234 -MD0=MB(0~~3) 235 - 236 -MD4=MB(4~~7) 237 - 238 -Address value is a multiple of 4 239 -))) 240 -|I|IW|IW d|d:0-99999| 241 -|Q|QW|QW d|d:0-99999| 242 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 243 -nn:0-9999 244 - 245 -dddd:0-9999 246 -)))|((( 247 -nn:DB No. 248 - 249 -dddd:address value 250 -))) 251 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 252 -nn:0-9999 253 - 254 -dddd:0-9999 255 -)))|((( 256 -nn:DB No. 257 - 258 -dddd:address value 259 - 260 -Address value is a multiple of 2 261 -))) 262 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 263 -nn:0-9999 264 - 265 -dddd:0-9999 266 -)))|((( 267 -nn:DB No. 268 - 269 -dddd:address value 270 - 271 -Address value is a multiple of 4 272 -))) 273 - 274 -**Communication Settings** 275 - 276 -Enable HMI Ethernet in [Project Settings] 277 - 278 278 == **S7-XXX Ethernet** == 279 279 280 280 Supported Series: Siemens S7-400, S7-1200 and S7-1500 281 281 282 -**V-BOX setting** 190 +**1)V-BOX setting** 283 283 284 284 |=**Items**|=**Settings**|=**Note** 285 285 |Protocol|Siemens S7-XXX| ... ... @@ -292,11 +292,11 @@ 292 292 293 293 Rack from TIA Portal is equal to HMI No. of V-net 294 294 295 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 203 +{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 296 296 297 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 205 +{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 298 298 299 -**Address List** 207 +**2)Address List** 300 300 301 301 |**Type**|**Device register**|**Format**|**Range**|**Note** 302 302 |(% rowspan="4" %)Bit|I|M d.o|((( ... ... @@ -376,9 +376,9 @@ 376 376 Address value is a multiple of 4 377 377 ))) 378 378 379 -**Configure the communication protocol** 287 +**3)Configure the communication protocol** 380 380 381 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 289 +{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 382 382 383 383 **✎Note:** 384 384 ... ... @@ -385,9 +385,9 @@ 385 385 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 386 386 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 387 387 388 -**Cable Wiring** 296 +**4)Cable Wiring** 389 389 390 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 298 +{{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 391 391 392 392 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 393 393
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.4 KB - Content