... ... @@ -191,6 +191,9 @@
191 191  |Port No.|102|
192 192  |PLC station No.|2|
193 193  
194 +(% style="text-align:center" %)
195 +[[image:西门子1200协议参数.png]]
196 +
194 194  **Address List**
195 195  
196 196  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
... ... @@ -271,10 +271,63 @@
271 271  Address value is a multiple of 4
272 272  )))
273 273  
274 -**Communication Settings**
277 +{{info}}
278 +✎Note:
275 275  
276 -Enable HMI Ethernet in [Project Settings]
280 +* The S7-1200 supports simultaneous connection of three devices.
281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address.
283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display
284 +{{/info}}
277 277  
286 +**PLC Settings**
287 +
288 +Add BD
289 +
290 +* Please uncheck [Symbolic access only] option;
291 +
292 +(% style="text-align:center" %)
293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]]
294 +
295 +Address settings, using BD2 as example.
296 +
297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
298 +* 2 represent DB block number
299 +* xxxx represent address
300 +
301 +**Such as:**
302 +
303 +* DBxDBB20000 = DB2.DBB0
304 +* DBxDBW20004 = DB2.DBW4
305 +
306 +(% style="text-align:center" %)
307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]]
308 +
309 +**How to connect with S7-1200 Firmware V4.0**
310 +
311 +PLC configuration
312 +
313 +* Double click [device configuration] in Siemens via software
314 +* Double click [protection] to enter protection configuration screen
315 +
316 +(% style="text-align:center" %)
317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]]
318 +
319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
320 +
321 +(% style="text-align:center" %)
322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]]
323 +
324 +DB settings
325 +
326 +* Right click [DB], select [properties]
327 +* Uncheck [optimized block access]
328 +
329 +**Cable Wiring**
330 +
331 +(% style="text-align:center" %)
332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]]
333 +
278 278  == **S7-XXX Ethernet** ==
279 279  
280 280  Supported Series: Siemens S7-400, S7-1200 and S7-1500
... ... @@ -424,30 +424,27 @@
424 424  
425 425  Click [Tools]~-~-[Ethernet Connections],shown as below.
426 426  
427 -{{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]
483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]
428 428  
429 429  Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
430 430  
431 -{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]
487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]
432 432  
433 433  **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
434 434  
435 -{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]
491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]
436 436  
437 437   **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
438 438  
439 -{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]
495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]
440 440  
441 441  **V-BOX Communication Settings**
442 442  
443 443  Set PLC IP in [IP Address] settings;
444 444  
445 -{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]]
501 +(% style="text-align:center" %)
502 +[[image:V-NET_Client logo.png]]
446 446  
447 -Enable V-BOX Ethernet in [Network];
448 -
449 -{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]]
450 -
451 451  TSAP setting
452 452  
453 453  * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
V-NET_Client logo.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +22.4 KB
Content
V-NET_Client logo8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +22.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +82.1 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +133.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@