Changes for page Siemens

Last modified by Joe on 2024/08/30 14:46

From version 46.1
edited by Theodore Xu
on 2023/10/12 17:06
Change comment: There is no comment for this version
To version 48.2
edited by Joe
on 2024/04/28 11:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.joe
Content
... ... @@ -484,9 +484,10 @@
484 484  
485 485  Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
486 486  
487 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]
487 +(% style="text-align:center" %)
488 +[[image:hXadxkZTuR.png]]
488 488  
489 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
490 +**TSAP set**: The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
490 490  
491 491  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]
492 492  
... ... @@ -498,22 +498,28 @@
498 498  
499 499  Set PLC IP in [IP Address] settings;
500 500  
501 -{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]]
502 +(% style="text-align:center" %)
503 +[[image:V-NET_Client logo.png]]
502 502  
503 -Enable V-BOX Ethernet in [Network];
504 -
505 -{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]]
506 -
507 507  TSAP setting
508 508  
509 509  * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
510 510  
509 +You can copy the following script into V-net directly.
510 +
511 +(% class="box successmessage" %)
512 +(((
511 511  **function** **init**.main()
512 512   addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address//
513 513   addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address//
514 514  **end**
517 +)))
515 515  
516 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
519 +(% class="box infomessage" %)
520 +(((
521 +Note:
522 +The name of the test script must be “init”, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
523 +)))
517 517  
518 518  **✎Note:**
519 519  
... ... @@ -524,4 +524,4 @@
524 524  ** Other set as defaulted.
525 525  * **Notes on the use of registers:**
526 526  ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
527 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
534 +** Register VW: Use only registers they are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
Ht1GZiel7c.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +56.3 KB
Content
V-NET_Client logo.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +22.4 KB
Content
V-NET_Client logo8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +22.4 KB
Content
hXadxkZTuR.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +57.5 KB
Content