From version 46.1
edited by Theodore Xu
on 2023/10/12 17:06
on 2023/10/12 17:06
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.joe - Content
-
... ... @@ -484,9 +484,10 @@ 484 484 485 485 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 486 486 487 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 487 +(% style="text-align:center" %) 488 +[[image:hXadxkZTuR.png]] 488 488 489 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 490 +**TSAP set**: The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 490 490 491 491 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 492 492 ... ... @@ -498,22 +498,28 @@ 498 498 499 499 Set PLC IP in [IP Address] settings; 500 500 501 -{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]] 502 +(% style="text-align:center" %) 503 +[[image:V-NET_Client logo.png]] 502 502 503 -Enable V-BOX Ethernet in [Network]; 504 - 505 -{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]] 506 - 507 507 TSAP setting 508 508 509 509 * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 510 510 509 +You can copy the following script into V-net directly. 510 + 511 +(% class="box successmessage" %) 512 +((( 511 511 **function** **init**.main() 512 512 addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address// 513 513 addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address// 514 514 **end** 517 +))) 515 515 516 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 519 +(% class="box infomessage" %) 520 +((( 521 +Note: 522 +The name of the test script must be “init”, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 523 +))) 517 517 518 518 **✎Note:** 519 519 ... ... @@ -524,4 +524,4 @@ 524 524 ** Other set as defaulted. 525 525 * **Notes on the use of registers:** 526 526 ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 527 -** Register VW: Use only registers th ay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )534 +** Register VW: Use only registers they are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
- Ht1GZiel7c.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.3 KB - Content
- V-NET_Client logo.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- V-NET_Client logo8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- hXadxkZTuR.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.5 KB - Content