From version 48.2
edited by Joe
on 2024/04/28 11:16
on 2024/04/28 11:16
Change comment:
There is no comment for this version
To version 46.1
edited by Theodore Xu
on 2023/10/12 17:06
on 2023/10/12 17:06
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.AiXia - Content
-
... ... @@ -484,10 +484,9 @@ 484 484 485 485 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 486 486 487 -(% style="text-align:center" %) 488 -[[image:hXadxkZTuR.png]] 487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 489 489 490 -**TSAP set**: 489 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 491 491 492 492 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 493 493 ... ... @@ -499,28 +499,22 @@ 499 499 500 500 Set PLC IP in [IP Address] settings; 501 501 502 -(% style="text-align:center" %) 503 -[[image:V-NET_Client logo.png]] 501 +{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]] 504 504 503 +Enable V-BOX Ethernet in [Network]; 504 + 505 +{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]] 506 + 505 505 TSAP setting 506 506 507 507 * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 508 508 509 -You can copy the following script into V-net directly. 510 - 511 -(% class="box successmessage" %) 512 -((( 513 513 **function** **init**.main() 514 514 addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address// 515 515 addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address// 516 516 **end** 517 -))) 518 518 519 -(% class="box infomessage" %) 520 -((( 521 -Note: 522 -The name of the test script must be “init”, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 523 -))) 516 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 524 524 525 525 **✎Note:** 526 526 ... ... @@ -531,4 +531,4 @@ 531 531 ** Other set as defaulted. 532 532 * **Notes on the use of registers:** 533 533 ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 534 -** Register VW: Use only registers th ey are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )527 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
- Ht1GZiel7c.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.3 KB - Content
- V-NET_Client logo.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.4 KB - Content
- V-NET_Client logo8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.4 KB - Content
- hXadxkZTuR.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.5 KB - Content