From version 49.3
edited by Joe
on 2024/04/30 14:53
on 2024/04/30 14:53
Change comment:
There is no comment for this version
To version 45.1
edited by Theodore Xu
on 2023/10/12 16:37
on 2023/10/12 16:37
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 12 removed)
- BSRBeEWL0O.png
- Ht1GZiel7c.png
- V-NET_Client logo.png
- V-NET_Client logo8.png
- hXadxkZTuR.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- yUYuRVmMcL.png
- 西门子1200协议参数.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.AiXia - Content
-
... ... @@ -191,9 +191,6 @@ 191 191 |Port No.|102| 192 192 |PLC station No.|2| 193 193 194 -(% style="text-align:center" %) 195 -[[image:西门子1200协议参数.png]] 196 - 197 197 **Address List** 198 198 199 199 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** ... ... @@ -274,77 +274,10 @@ 274 274 Address value is a multiple of 4 275 275 ))) 276 276 277 -{{info}} 278 -✎Note: 274 +**Communication Settings** 279 279 280 -* The S7-1200 supports simultaneous connection of three devices. 281 -* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 -* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 -{{/info}} 276 +Enable HMI Ethernet in [Project Settings] 284 284 285 -**PLC Settings** 286 - 287 -Add BD 288 - 289 -* Please uncheck [Symbolic access only] option; 290 - 291 -(% style="text-align:center" %) 292 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 293 - 294 -Address settings, using BD2 as example. 295 - 296 -* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 297 -* 2 represent DB block number 298 -* xxxx represent address 299 - 300 -**Such as:** 301 - 302 -* DBxDBB20000 = DB2.DBB0 303 -* DBxDBW20004 = DB2.DBW4 304 - 305 -(% style="text-align:center" %) 306 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 307 - 308 -**How to setting String in PLC and V-net** 309 -PLC configuration 310 - 311 -choosing Data type~-~-String→add"[]" after String and input data length 312 - 313 -(% style="text-align:center" %) 314 -[[image:yUYuRVmMcL.png]] 315 - 316 -V-box configuration 317 - 318 -(% style="text-align:center" %) 319 -[[image:BSRBeEWL0O.png]] 320 - 321 -choosing Word and DBxDBW →input register number →Data format is String →input data length you want to use → choosing Byte corder~-~-Little-endian 322 - 323 -**How to connect with S7-1200 Firmware V4.0** 324 - 325 -PLC configuration 326 - 327 -* Double click [device configuration] in Siemens via software 328 -* Double click [protection] to enter protection configuration screen 329 - 330 -(% style="text-align:center" %) 331 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 332 - 333 -* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 334 - 335 -(% style="text-align:center" %) 336 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 337 - 338 -DB settings 339 - 340 -* Right click [DB], select [properties] 341 -* Uncheck [optimized block access] 342 - 343 -**Cable Wiring** 344 - 345 -(% style="text-align:center" %) 346 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 347 - 348 348 == **S7-XXX Ethernet** == 349 349 350 350 Supported Series: Siemens S7-400, S7-1200 and S7-1500 ... ... @@ -494,47 +494,40 @@ 494 494 495 495 Click [Tools]~-~-[Ethernet Connections],shown as below. 496 496 497 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 427 +{{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 498 498 499 499 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 500 500 501 -(% style="text-align:center" %) 502 -[[image:hXadxkZTuR.png]] 431 +{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 503 503 504 -**TSAP set**: 433 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 505 505 506 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 435 +{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 507 507 508 508 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 509 509 510 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 439 +{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 511 511 512 512 **V-BOX Communication Settings** 513 513 514 514 Set PLC IP in [IP Address] settings; 515 515 516 -(% style="text-align:center" %) 517 -[[image:V-NET_Client logo.png]] 445 +{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]] 518 518 447 +Enable V-BOX Ethernet in [Network]; 448 + 449 +{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]] 450 + 519 519 TSAP setting 520 520 521 521 * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 522 522 523 -You can copy the following script into V-net directly. 524 - 525 -(% class="box successmessage" %) 526 -((( 527 527 **function** **init**.main() 528 528 addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address// 529 529 addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address// 530 530 **end** 531 -))) 532 532 533 -(% class="box infomessage" %) 534 -((( 535 -Note: 536 -The name of the test script must be “init”, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 537 -))) 460 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 538 538 539 539 **✎Note:** 540 540 ... ... @@ -545,4 +545,4 @@ 545 545 ** Other set as defaulted. 546 546 * **Notes on the use of registers:** 547 547 ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 548 -** Register VW: Use only registers th ey are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )471 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
- BSRBeEWL0O.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -30.0 KB - Content
- Ht1GZiel7c.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.3 KB - Content
- V-NET_Client logo.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.4 KB - Content
- V-NET_Client logo8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.4 KB - Content
- hXadxkZTuR.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.5 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- yUYuRVmMcL.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.6 KB - Content