**PLC Settings** |
286 |
286 |
|
287 |
|
-Add BD |
288 |
288 |
|
289 |
|
-* Please uncheck [Symbolic access only] option; |
|
288 |
+In the Project tree [PLC project]→Right-click[PLC-1]→[Properties]→[General]→[PROFINE interface]→[Add new subnet]→[IP address]192.168.40.20,[Subnet mask]255.255.255.0→[OK] |
290 |
290 |
|
291 |
291 |
(% style="text-align:center" %) |
292 |
|
-[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] |
|
291 |
+[[image:图片1.png]] |
293 |
293 |
|
|
293 |
+Open [Properties] again→[General]→[Protection&Security]→[Connection mechanisms]→Check [Permit access with PUTIGET communication remote partner ]→[OK] |
|
294 |
+ |
|
295 |
+(% style="text-align:center" %) |
|
296 |
+[[image:图片2.png]] |
|
297 |
+ |
|
298 |
+Create a new DB block: |
|
299 |
+ |
|
300 |
+[Add new block]→[Date block]→[Manual]→[OK] |
|
301 |
+ |
|
302 |
+(% style="text-align:center" %) |
|
303 |
+[[image:图片3.png]] |
|
304 |
+ |
|
305 |
+Right-click[DB1]→[Properties]→[General]→[Attributes]→Uncheck[Optimized block access]→[OK] |
|
306 |
+ |
|
307 |
+(% style="text-align:center" %) |
|
308 |
+[[image:图片4.png]] |
|
309 |
+ |
|
310 |
+ |
294 |
294 |
Address settings, using BD2 as example. |
295 |
295 |
|
296 |
296 |
* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. |
... |
... |
@@ -311,7 +311,7 @@ |
311 |
311 |
choosing Data type~-~-String→add"[]" after String and input data length |
312 |
312 |
|
313 |
313 |
(% style="text-align:center" %) |
314 |
|
-[[image:yUYuRVmMcL.png]] |
|
331 |
+[[image:2J0mzCcSR4.png]] |
315 |
315 |
|
316 |
316 |
V-box configuration |
317 |
317 |
|
... |
... |
@@ -318,8 +318,15 @@ |
318 |
318 |
(% style="text-align:center" %) |
319 |
319 |
[[image:BSRBeEWL0O.png]] |
320 |
320 |
|
321 |
|
-choosing Word and DBxDBW →input register number →Data format is String →input data length you want to use → choosing Byte corder~-~-Little-endian |
|
338 |
+choosing Word and DBxDBW →input Register Main No. →Data format is String →input data length you want to use → choosing Byte order~-~-Little-endian |
322 |
322 |
|
|
340 |
+(% class="box infomessage" %) |
|
341 |
+((( |
|
342 |
+Note: Register Main No. = offset in PLC + 2 |
|
343 |
+For example, the image above has an offset of 4, so the register Main No. is 10006 |
|
344 |
+If an offset is 8, the register Main No. is 10010 |
|
345 |
+))) |
|
346 |
+ |
323 |
323 |
**How to connect with S7-1200 Firmware V4.0** |
324 |
324 |
|
325 |
325 |
PLC configuration |
... |
... |
@@ -497,11 +497,12 @@ |
497 |
497 |
[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] |
498 |
498 |
|
499 |
499 |
Set Ethernet connection parameter. IP, Subnet Mask, shown as below. |
|
524 |
+ |
500 |
500 |
|
501 |
501 |
(% style="text-align:center" %) |
502 |
|
-[[image:hXadxkZTuR.png]] |
|
527 |
+[[image:1iZSZTpAdk.png]] |
503 |
503 |
|
504 |
|
-**TSAP set**: The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. |
|
529 |
+**TSAP set**: The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite, shown as below. |
505 |
505 |
|
506 |
506 |
[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] |