@@ -284,30 +284,13 @@ |
284 |
284 |
|
285 |
285 |
**PLC Settings** |
286 |
286 |
|
|
287 |
+Add BD |
287 |
287 |
|
288 |
|
-In the Project tree [PLC project]→Right-click[PLC-1]→[Properties]→[General]→[PROFINE interface]→[Add new subnet]→[IP address]192.168.40.20,[Subnet mask]255.255.255.0→[OK] |
|
289 |
+* Please uncheck [Symbolic access only] option; |
289 |
289 |
|
290 |
290 |
(% style="text-align:center" %) |
291 |
|
-[[image:图片1.png]] |
|
292 |
+[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] |
292 |
292 |
|
293 |
|
-Open [Properties] again→[General]→[Protection&Security]→[Connection mechanisms]→Check [Permit access with PUTIGET communication remote partner ]→[OK] |
294 |
|
- |
295 |
|
-(% style="text-align:center" %) |
296 |
|
-[[image:图片2.png]] |
297 |
|
- |
298 |
|
-Create a new DB block: |
299 |
|
- |
300 |
|
-[Add new block]→[Date block]→[Manual]→[OK] |
301 |
|
- |
302 |
|
-(% style="text-align:center" %) |
303 |
|
-[[image:图片3.png]] |
304 |
|
- |
305 |
|
-Right-click[DB1]→[Properties]→[General]→[Attributes]→Uncheck[Optimized block access]→[OK] |
306 |
|
- |
307 |
|
-(% style="text-align:center" %) |
308 |
|
-[[image:图片4.png]] |
309 |
|
- |
310 |
|
- |
311 |
311 |
Address settings, using BD2 as example. |
312 |
312 |
|
313 |
313 |
* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. |
... |
... |
@@ -335,15 +335,8 @@ |
335 |
335 |
(% style="text-align:center" %) |
336 |
336 |
[[image:BSRBeEWL0O.png]] |
337 |
337 |
|
338 |
|
-choosing Word and DBxDBW →input Register Main No. →Data format is String →input data length you want to use → choosing Byte order~-~-Little-endian |
|
321 |
+choosing Word and DBxDBW →input register number →Data format is String →input data length you want to use → choosing Byte corder~-~-Little-endian |
339 |
339 |
|
340 |
|
-(% class="box infomessage" %) |
341 |
|
-((( |
342 |
|
-Note: Register Main No. = offset in PLC + 2 |
343 |
|
-For example, the image above has an offset of 4, so the register Main No. is 10006 |
344 |
|
-If an offset is 8, the register Main No. is 10010 |
345 |
|
-))) |
346 |
|
- |
347 |
347 |
**How to connect with S7-1200 Firmware V4.0** |
348 |
348 |
|
349 |
349 |
PLC configuration |
... |
... |
@@ -521,12 +521,11 @@ |
521 |
521 |
[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] |
522 |
522 |
|
523 |
523 |
Set Ethernet connection parameter. IP, Subnet Mask, shown as below. |
524 |
|
- |
525 |
525 |
|
526 |
526 |
(% style="text-align:center" %) |
527 |
|
-[[image:1iZSZTpAdk.png]] |
|
502 |
+[[image:hXadxkZTuR.png]] |
528 |
528 |
|
529 |
|
-**TSAP set**: The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite, shown as below. |
|
504 |
+**TSAP set**: The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. |
530 |
530 |
|
531 |
531 |
[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] |
532 |
532 |
|