1 | == **S7-200 Smart Serial** == | ||
2 | |||
3 | **V-BOX setting** | ||
4 | |||
5 | (% style="width:1323.87px" %) | ||
6 | |**Items**|**Settings**|**Note** | ||
7 | |Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| | ||
8 | |Connection|(% style="width:783px" %)RS485| | ||
9 | |Baud rate|(% style="width:783px" %)9600| | ||
10 | |Data bit|(% style="width:783px" %)8| | ||
11 | |Parity|(% style="width:783px" %)EVEN| | ||
12 | |Stop bit|(% style="width:783px" %)1| | ||
13 | |PLC station No.|(% style="width:783px" %)2| | ||
14 | |||
15 | (% style="text-align:center" %) | ||
16 | [[image:西门子200串口.png]] | ||
17 | |||
18 | **Address List ** | ||
19 | |||
20 | |**Type**|**Device register**|**Format**|**Range**|**Note** | ||
21 | |(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| | ||
22 | |Q|Q ddddd.o|0.0~~99999.7| | ||
23 | |V|VWbit ddddd.o|0.0~~99999.7| | ||
24 | |V|V ddddd.o|0.0~~99999.7| | ||
25 | |M|M ddddd.o|0.0~~99999.7| | ||
26 | |SM|ddddd.o|0.0~~99999.7| | ||
27 | |S|ddddd.o|0.0~~99999.7|Read only | ||
28 | |T|ddddd|0~~99999|Timer state, read only | ||
29 | |C|ddddd|0~~99999|Counter state, read only | ||
30 | |(% rowspan="12" %)Word|I|IW ddddd|0~~99999| | ||
31 | |Q|QW ddddd|0~~99999| | ||
32 | |AI|AIW ddddd|0~~99999| | ||
33 | |AQ|VB ddddd|0~~99999| | ||
34 | |V|VW ddddd|0~~99998|((( | ||
35 | VW0=VB (0~~1) | ||
36 | |||
37 | VW2=VB (2~~3) | ||
38 | |||
39 | Address value is a multiple of 2 | ||
40 | ))) | ||
41 | |V|VD ddddd|0~~99998|((( | ||
42 | VD0=VB (0~~3) | ||
43 | |||
44 | VD2=VB (4~~7) | ||
45 | |||
46 | Address value is a multiple of 4 | ||
47 | ))) | ||
48 | |M|MB ddddd|0~~99999| | ||
49 | |M|MW ddddd|0~~99999|((( | ||
50 | MW0=MB(0~~1) | ||
51 | |||
52 | MW2=MB(2~~3) | ||
53 | |||
54 | Address value is a multiple of 2 | ||
55 | ))) | ||
56 | |M|MD ddddd|0~~99999|((( | ||
57 | MD0=MB(0~~3) | ||
58 | |||
59 | MD4=MB(4~~7) | ||
60 | |||
61 | Address value is a multiple of 4 | ||
62 | ))) | ||
63 | |T|TW ddddd|0~~99999|Value of timer | ||
64 | |C|CW ddddd|0~~99999|Value of counter | ||
65 | |W|SW ddddd|0~~99999| | ||
66 | |||
67 | **PLC setting** | ||
68 | |||
69 | (% style="text-align:center" %) | ||
70 | [[image:西门子软件版本.png]] | ||
71 | |||
72 | (% style="text-align:center" %) | ||
73 | [[image:485通讯配置.png]] | ||
74 | |||
75 | **Connect and Download** | ||
76 | |||
77 | (% style="text-align:center" %) | ||
78 | [[image:以太网 PC和PLC连接.png]] | ||
79 | |||
80 | (% style="text-align:center" %) | ||
81 | [[image:以太网下载.png]] | ||
82 | |||
83 | **Cable Wiring** | ||
84 | |||
85 | (% style="text-align:center" %) | ||
86 | [[image:485接线.png]] | ||
87 | |||
88 | == **S7-200 Smart Ethernet ** == | ||
89 | |||
90 | **V-BOX setting** | ||
91 | |||
92 | |**Items**|**Settings** | ||
93 | |Protocol|Siemens S7-200 Smart(Ethernet) | ||
94 | |Connection|Ethernet | ||
95 | |Port No.|102 | ||
96 | |PLC station No.|2 | ||
97 | |||
98 | (% style="text-align:center" %) | ||
99 | [[image:西门子200smart 以太网.png]] | ||
100 | |||
101 | **PLC setting** | ||
102 | |||
103 | (% style="text-align:center" %) | ||
104 | [[image:西门子软件版本.png]] | ||
105 | |||
106 | (% style="text-align:center" %) | ||
107 | [[image:以太网通讯配置.png]] | ||
108 | |||
109 | **Connect and Download** | ||
110 | |||
111 | (% style="text-align:center" %) | ||
112 | [[image:以太网 PC和PLC连接.png]] | ||
113 | |||
114 | (% style="text-align:center" %) | ||
115 | [[image:以太网下载.png]] | ||
116 | |||
117 | **Cable Wiring** | ||
118 | |||
119 | V-Box : RJ45 Ethernet interface | ||
120 | |||
121 | PLC : RJ45 Ethernet interface | ||
122 | |||
123 | (% style="text-align:center" %) | ||
124 | [[image:以太网连接.png]] | ||
125 | |||
126 | == **S7-300 Ethernet ** == | ||
127 | |||
128 | Supported Series: Siemens S7-300 series PLC | ||
129 | |||
130 | **V-BOX setting** | ||
131 | |||
132 | |**Items**|**Settings**|**Note** | ||
133 | |Protocol|Simens S7-300 Ethernet| | ||
134 | |Connection|Ethernet| | ||
135 | |Port No.|102| | ||
136 | |PLC station No.|2|Need to be same as the PLC setting | ||
137 | |||
138 | **Address List** | ||
139 | |||
140 | |**Type**|**Device register**|**Format**|**Range**|**Note** | ||
141 | |(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| | ||
142 | |Q|Q ddddd.o|0.0~~99999.7| | ||
143 | |M|M ddddd.o|0.0~~99999.7| | ||
144 | |DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( | ||
145 | nn: block number; | ||
146 | |||
147 | dddd: address; | ||
148 | ))) | ||
149 | |(% rowspan="8" %)Word|I|IW ddddd|0~~99999| | ||
150 | |Q|QW ddddd|0~~99999| | ||
151 | |(% rowspan="3" %)M|MB ddddd|0~~99999| | ||
152 | |MW ddddd|0~~99999|((( | ||
153 | MW0=MB(0~~1) | ||
154 | |||
155 | MW2=MB(2~~3) | ||
156 | |||
157 | Address value is a multiple of 2 | ||
158 | ))) | ||
159 | |MD ddddd|0~~99999|((( | ||
160 | MD0=MB(0~~3) | ||
161 | |||
162 | MD4=MB(4~~7) | ||
163 | |||
164 | Address value is a multiple of 4 | ||
165 | ))) | ||
166 | |(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( | ||
167 | nn: block number; | ||
168 | |||
169 | dddd: address | ||
170 | ))) | ||
171 | |DBxDBW nndddd|0~~99999999 | ||
172 | |DBxDBD nndddd|0~~99999999 | ||
173 | |||
174 | **Configure the communication protocol** | ||
175 | |||
176 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] | ||
177 | |||
178 | **Cable Wiring** | ||
179 | |||
180 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] | ||
181 | |||
182 | == **S7-1200 Ethernet ** == | ||
183 | |||
184 | [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] | ||
185 | |||
186 | **V-BOX Setting** | ||
187 | |||
188 | |**Items**|**Settings**|**Note** | ||
189 | |Protocol|Siemens S7-1200| | ||
190 | |Connection|Ethernet| | ||
191 | |Port No.|102| | ||
192 | |PLC station No.|2| | ||
193 | |||
194 | (% style="text-align:center" %) | ||
195 | [[image:西门子1200协议参数.png]] | ||
196 | |||
197 | **Address List** | ||
198 | |||
199 | |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** | ||
200 | |(% rowspan="4" %)Bit|I|I|M d.o|((( | ||
201 | d:0~-~-9999 | ||
202 | |||
203 | o:0-7 | ||
204 | )))| | ||
205 | |Q|Q|Q d.o|((( | ||
206 | d:0~-~-9999 | ||
207 | |||
208 | o:0-7 | ||
209 | )))| | ||
210 | |M|M|M d.o|((( | ||
211 | d:0~-~-9999 | ||
212 | |||
213 | o:0-7 | ||
214 | )))| | ||
215 | |DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( | ||
216 | nn:0-9999, | ||
217 | |||
218 | dddd:0-9999, | ||
219 | |||
220 | o:0-7 | ||
221 | )))|((( | ||
222 | nn:DB No. | ||
223 | |||
224 | dddd:address value | ||
225 | |||
226 | o: digit address | ||
227 | ))) | ||
228 | |(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| | ||
229 | |M|MW|MW d|d:0-99999|((( | ||
230 | MW0=MB(0~~1) | ||
231 | |||
232 | MW2=MB(2~~3) | ||
233 | |||
234 | Address value is a multiple of 2 | ||
235 | ))) | ||
236 | |M|MD|MD d|d:0-99999|((( | ||
237 | MD0=MB(0~~3) | ||
238 | |||
239 | MD4=MB(4~~7) | ||
240 | |||
241 | Address value is a multiple of 4 | ||
242 | ))) | ||
243 | |I|IW|IW d|d:0-99999| | ||
244 | |Q|QW|QW d|d:0-99999| | ||
245 | |DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( | ||
246 | nn:0-9999 | ||
247 | |||
248 | dddd:0-9999 | ||
249 | )))|((( | ||
250 | nn:DB No. | ||
251 | |||
252 | dddd:address value | ||
253 | ))) | ||
254 | |DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( | ||
255 | nn:0-9999 | ||
256 | |||
257 | dddd:0-9999 | ||
258 | )))|((( | ||
259 | nn:DB No. | ||
260 | |||
261 | dddd:address value | ||
262 | |||
263 | Address value is a multiple of 2 | ||
264 | ))) | ||
265 | |DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( | ||
266 | nn:0-9999 | ||
267 | |||
268 | dddd:0-9999 | ||
269 | )))|((( | ||
270 | nn:DB No. | ||
271 | |||
272 | dddd:address value | ||
273 | |||
274 | Address value is a multiple of 4 | ||
275 | ))) | ||
276 | |||
277 | {{info}} | ||
278 | ✎Note: | ||
279 | |||
280 | * The S7-1200 supports simultaneous connection of three devices. | ||
281 | * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. | ||
282 | * S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. | ||
283 | {{/info}} | ||
284 | |||
285 | **PLC Settings** | ||
286 | |||
287 | Add BD | ||
288 | |||
289 | * Please uncheck [Symbolic access only] option; | ||
290 | |||
291 | (% style="text-align:center" %) | ||
292 | [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] | ||
293 | |||
294 | Address settings, using BD2 as example. | ||
295 | |||
296 | * DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. | ||
297 | * 2 represent DB block number | ||
298 | * xxxx represent address | ||
299 | |||
300 | **Such as:** | ||
301 | |||
302 | * DBxDBB20000 = DB2.DBB0 | ||
303 | * DBxDBW20004 = DB2.DBW4 | ||
304 | |||
305 | (% style="text-align:center" %) | ||
306 | [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] | ||
307 | |||
308 | **How to setting String in PLC and V-net** | ||
309 | PLC configuration | ||
310 | |||
311 | choosing Data type~-~-String→add"[]" after String and input data length | ||
312 | |||
313 | (% style="text-align:center" %) | ||
314 | [[image:yUYuRVmMcL.png]] | ||
315 | |||
316 | V-box configuration | ||
317 | |||
318 | (% style="text-align:center" %) | ||
319 | [[image:BSRBeEWL0O.png]] | ||
320 | |||
321 | choosing Word and DBxDBW →input Register Main No. →Data format is String →input data length you want to use → choosing Byte order~-~-Little-endian | ||
322 | |||
323 | (% class="box infomessage" %) | ||
324 | ((( | ||
325 | Note: Register Main No. = offset in PLC + 2 | ||
326 | For example, the image above has an offset of 4, so the register Main No. is 10006 | ||
327 | If an offset is 8, the register Main No. is 10010 | ||
328 | ))) | ||
329 | |||
330 | **How to connect with S7-1200 Firmware V4.0** | ||
331 | |||
332 | PLC configuration | ||
333 | |||
334 | * Double click [device configuration] in Siemens via software | ||
335 | * Double click [protection] to enter protection configuration screen | ||
336 | |||
337 | (% style="text-align:center" %) | ||
338 | [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] | ||
339 | |||
340 | * Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] | ||
341 | |||
342 | (% style="text-align:center" %) | ||
343 | [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] | ||
344 | |||
345 | DB settings | ||
346 | |||
347 | * Right click [DB], select [properties] | ||
348 | * Uncheck [optimized block access] | ||
349 | |||
350 | **Cable Wiring** | ||
351 | |||
352 | (% style="text-align:center" %) | ||
353 | [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] | ||
354 | |||
355 | == **S7-XXX Ethernet** == | ||
356 | |||
357 | Supported Series: Siemens S7-400, S7-1200 and S7-1500 | ||
358 | |||
359 | **V-BOX setting** | ||
360 | |||
361 | |=**Items**|=**Settings**|=**Note** | ||
362 | |Protocol|Siemens S7-XXX| | ||
363 | |Connection|Ethernet| | ||
364 | |Port No.|102| | ||
365 | |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| | ||
366 | |HMI No.|Rack (Default as 0)| | ||
367 | |||
368 | Slot from TIA Portal is equal to Device No. of V-net | ||
369 | |||
370 | Rack from TIA Portal is equal to HMI No. of V-net | ||
371 | |||
372 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] | ||
373 | |||
374 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] | ||
375 | |||
376 | **Address List** | ||
377 | |||
378 | |**Type**|**Device register**|**Format**|**Range**|**Note** | ||
379 | |(% rowspan="4" %)Bit|I|M d.o|((( | ||
380 | d:0~-~-9999 | ||
381 | |||
382 | o:0-7 | ||
383 | )))| | ||
384 | |Q|Q d.o|((( | ||
385 | d:0~-~-9999 | ||
386 | |||
387 | o:0-7 | ||
388 | )))| | ||
389 | |M|M d.o|((( | ||
390 | d:0~-~-9999 | ||
391 | |||
392 | o:0-7 | ||
393 | )))| | ||
394 | |DB0.DB-DB99.DB|DBxDBnndddd.o|((( | ||
395 | nn:0-9999, | ||
396 | |||
397 | dddd:0-9999, | ||
398 | |||
399 | o:0-7 | ||
400 | )))|((( | ||
401 | nn:DB No. | ||
402 | |||
403 | dddd:address value | ||
404 | |||
405 | o: digit address | ||
406 | ))) | ||
407 | |(% rowspan="8" %)Word|M|MB d|d:0-99999| | ||
408 | |M|MW d|d:0-99999|((( | ||
409 | MW0=MB(0~~1) | ||
410 | |||
411 | MW2=MB(2~~3) | ||
412 | |||
413 | Address value is a multiple of 2 | ||
414 | ))) | ||
415 | |M|MD d|d:0-99999|((( | ||
416 | MD0=MB(0~~3) | ||
417 | |||
418 | MD4=MB(4~~7) | ||
419 | |||
420 | Address value is a multiple of 4 | ||
421 | ))) | ||
422 | |I|IW d|d:0-99999| | ||
423 | |Q|QW d|d:0-99999| | ||
424 | |DB0.DB-DB99.DB|DBxDBBnndddd|((( | ||
425 | nn:0-9999 | ||
426 | |||
427 | dddd:0-9999 | ||
428 | )))|((( | ||
429 | nn:DB No. | ||
430 | |||
431 | dddd:address value | ||
432 | ))) | ||
433 | |DB0.DB-DB99.DB|DBxDBWnndddd|((( | ||
434 | nn:0-9999 | ||
435 | |||
436 | dddd:0-9999 | ||
437 | )))|((( | ||
438 | nn:DB No. | ||
439 | |||
440 | dddd:address value | ||
441 | |||
442 | Address value is a multiple of 2 | ||
443 | ))) | ||
444 | |DB0.DB-DB99.DB|DBxDBDnndddd|((( | ||
445 | nn:0-9999 | ||
446 | |||
447 | dddd:0-9999 | ||
448 | )))|((( | ||
449 | nn:DB No. | ||
450 | |||
451 | dddd:address value | ||
452 | |||
453 | Address value is a multiple of 4 | ||
454 | ))) | ||
455 | |||
456 | **Configure the communication protocol** | ||
457 | |||
458 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] | ||
459 | |||
460 | **✎Note:** | ||
461 | |||
462 | * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. | ||
463 | * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. | ||
464 | |||
465 | **Cable Wiring** | ||
466 | |||
467 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] | ||
468 | |||
469 | == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == | ||
470 | |||
471 | Supported Series: Siemens Logo 0BA0, 0BA1 series | ||
472 | |||
473 | **V-BOX Settings** | ||
474 | |||
475 | |**Items**|**Settings**|**Note** | ||
476 | |Protocol|Siemens LOGO| | ||
477 | |Connection|Ethernet| | ||
478 | |Port No.|102| | ||
479 | |PLC station No.|2| | ||
480 | |||
481 | **Address List** | ||
482 | |||
483 | |**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** | ||
484 | |1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 | ||
485 | |2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 | ||
486 | |3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 | ||
487 | |4|VW|Word|0-1468|DB1.DBX0.0|0x000000 | ||
488 | |5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 | ||
489 | |6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 | ||
490 | |7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 | ||
491 | |8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 | ||
492 | |9|AI|Word|1-16|DB1.DBX1032.0|0x002040 | ||
493 | |10|I|Bit|1-64|DB1.DBX1024.0|0x002000 | ||
494 | |11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 | ||
495 | |12|M|Bit|1-112|DB1.DBX1104.0|0x002280 | ||
496 | |13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 | ||
497 | |14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 | ||
498 | |15|V|Bit|0-14697|DB1.DBX0.0|0x000000 | ||
499 | |||
500 | **PLC Settings in LOGO Software:** | ||
501 | |||
502 | Click [Tools]~-~-[Ethernet Connections],shown as below. | ||
503 | |||
504 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] | ||
505 | |||
506 | Set Ethernet connection parameter. IP, Subnet Mask, shown as below. | ||
507 | |||
508 | |||
509 | (% style="text-align:center" %) | ||
510 | [[image:1iZSZTpAdk.png]] | ||
511 | |||
512 | **TSAP set**: The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite, shown as below. | ||
513 | |||
514 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] | ||
515 | |||
516 | **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. | ||
517 | |||
518 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] | ||
519 | |||
520 | **V-BOX Communication Settings** | ||
521 | |||
522 | Set PLC IP in [IP Address] settings; | ||
523 | |||
524 | (% style="text-align:center" %) | ||
525 | [[image:V-NET_Client logo.png]] | ||
526 | |||
527 | TSAP setting | ||
528 | |||
529 | * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. | ||
530 | |||
531 | You can copy the following script into V-net directly. | ||
532 | |||
533 | (% class="box successmessage" %) | ||
534 | ((( | ||
535 | **function** **init**.main() | ||
536 | addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address// | ||
537 | addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address// | ||
538 | **end** | ||
539 | ))) | ||
540 | |||
541 | (% class="box infomessage" %) | ||
542 | ((( | ||
543 | Note: | ||
544 | The name of the test script must be “init”, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. | ||
545 | ))) | ||
546 | |||
547 | **✎Note:** | ||
548 | |||
549 | * **Communication port configuration: ** | ||
550 | ** Continuous length needs to be set to 0. | ||
551 | ** Integration interval needs to be set to 1. (no change may result in data errors) | ||
552 | ** Set Port and Device Station NO. | ||
553 | ** Other set as defaulted. | ||
554 | * **Notes on the use of registers:** | ||