Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 10.1
edited by Theodore Xu
on 2023/07/11 16:30
on 2023/07/11 16:30
Change comment:
There is no comment for this version
To version 14.1
edited by Theodore Xu
on 2023/08/23 15:47
on 2023/08/23 15:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2302,23 +2302,17 @@ 2302 2302 |(% rowspan="9" %)**FA.15**|(% colspan="2" style="width:442px" %)Fault protection action selection 3|(% style="width:451px" %)Default|(% colspan="2" %)00000 2303 2303 |(% rowspan="7" %)Setting range|(% style="width:316px" %)Ones Place|(% colspan="3" style="width:978px" %)User-defined fault 1(Err27) (0~~2,as ones place of FA.13) 2304 2304 |(% style="width:316px" %)Tens Place|(% colspan="3" style="width:978px" %)User-defined fault 2(Err28) (0~~2,as ones place of FA.13) 2305 -|(% style="width:316px" %)Hundr -eds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)2306 -|(% style="width:316px" %)Thous -ands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)2305 +|(% style="width:316px" %)Hundreds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13) 2306 +|(% style="width:316px" %)Thousands Place|(% colspan="3" style="width:978px" %)Load loss(Err30) 2307 2307 |(% style="width:316px" %)0|(% colspan="3" style="width:978px" %)Free stopping 2308 2308 |(% style="width:316px" %)1|(% colspan="3" style="width:978px" %)Stop according to the stop mode 2309 2309 |(% style="width:316px" %)2|(% colspan="3" style="width:978px" %)Decelerate to 7% of the rated frequency of the motor and continue to run, and automatically return to the set frequency if the load is not lost 2310 -| |(% style="width:316px" %)Ten thous -ands Place|(% colspan="3" style="width:978px" %)(((2310 +| |(% style="width:316px" %)Ten thousands Place|(% colspan="3" style="width:978px" %)((( 2311 2311 PID feedback loss during 2312 2312 2313 2313 Running (Err31) (0~~2,as ones place of FA.13) 2314 2314 ))) 2315 -|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)((( 2316 -Overcurrent stall Integral coefficient 2317 -)))|(% colspan="2" style="width:451px" %)Default|500 2318 -|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000 2319 2319 2320 -set overcurrent stall Integral coefficient rate. 2321 - 2322 2322 When “free stop” is selected: the inverter prompts Err~*~* and stops directly. 2323 2323 2324 2324 When "Stop according to stop mode" is selected: the inverter prompts A~*~* and stops according to the stop mode, and prompts ErrXX after stopping. ... ... @@ -2326,22 +2326,29 @@ 2326 2326 When “continue running” is selected: the inverter continues to run and prompts A~*~*. For the running frequency, refer to the description of FA.20 and FA.21. 2327 2327 2328 2328 (% class="table-bordered" %) 2329 -|(% rowspan="2" %)((( 2330 -FA.17 2331 -)))|((( 2332 -Undervoltage setting 2333 -)))|((( 2323 +|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)((( 2324 +Overcurrent stall Integral coefficient 2325 +)))|(% colspan="2" style="width:451px" %)Default|500 2326 +|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000 2327 + 2328 +Set overcurrent stall Integral coefficient rate. 2329 + 2330 +(% class="table-bordered" %) 2331 +|(% rowspan="3" %)((( 2332 +**FA.17** 2333 +)))|(% colspan="2" rowspan="1" %)Instant stop /no-stop mode |((( 2334 2334 Default 2335 2335 )))|((( 2336 - 100.0%2336 +0 2337 2337 ))) 2338 -|((( 2338 +|(% colspan="1" rowspan="2" %)((( 2339 2339 Setting range 2340 -)))|(% colspan="2" rowspan="1" %)((( 2341 - 60.0%~~140.0%2340 +)))|(% rowspan="1" %)0|(% colspan="2" rowspan="1" %)((( 2341 +General machine instant stop/no-stop 2342 2342 ))) 2343 +|1|(% colspan="2" %)Spinning machine instant stop/no-stop 2343 2343 2344 - Instantaneouspowerfailuremodeselection2345 +Set the mode of instant stop and no-stop. 2345 2345 2346 2346 (% class="table-bordered" %) 2347 2347 |(% rowspan="2" %)**FA.18**|Undervoltage setting|Default|100.0%