... ... @@ -51,7 +51,7 @@
51 51  |2|(% colspan="2" %)AI1
52 52  |3|(% colspan="2" %)AI2
53 53  |4|(% colspan="2" %)Reserved
54 -|5|(% colspan="2" %)PULSE setting(Reserved)
54 +|5|(% colspan="2" %)PULSE setting DI6(Reserved)
55 55  |6|(% colspan="2" %)Multi-stage speed setting
56 56  |7|(% colspan="2" %)Simple PLC
57 57  |8|(% colspan="2" %)PID
... ... @@ -2302,23 +2302,17 @@
2302 2302  |(% rowspan="9" %)**FA.15**|(% colspan="2" style="width:442px" %)Fault protection action selection 3|(% style="width:451px" %)Default|(% colspan="2" %)00000
2303 2303  |(% rowspan="7" %)Setting range|(% style="width:316px" %)Ones Place|(% colspan="3" style="width:978px" %)User-defined fault 1(Err27) (0~~2,as ones place of FA.13)
2304 2304  |(% style="width:316px" %)Tens Place|(% colspan="3" style="width:978px" %)User-defined fault 2(Err28) (0~~2,as ones place of FA.13)
2305 -|(% style="width:316px" %)Hundr-eds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)
2306 -|(% style="width:316px" %)Thous-ands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)
2305 +|(% style="width:316px" %)Hundreds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)
2306 +|(% style="width:316px" %)Thousands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)
2307 2307  |(% style="width:316px" %)0|(% colspan="3" style="width:978px" %)Free stopping
2308 2308  |(% style="width:316px" %)1|(% colspan="3" style="width:978px" %)Stop according to the stop mode
2309 2309  |(% style="width:316px" %)2|(% colspan="3" style="width:978px" %)Decelerate to 7% of the rated frequency of the motor and continue to run, and automatically return to the set frequency if the load is not lost
2310 -| |(% style="width:316px" %)Ten thous-ands Place|(% colspan="3" style="width:978px" %)(((
2310 +| |(% style="width:316px" %)Ten thousands Place|(% colspan="3" style="width:978px" %)(((
2311 2311  PID feedback loss during
2312 2312  
2313 2313  Running (Err31) (0~~2,as ones place of FA.13)
2314 2314  )))
2315 -|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)(((
2316 -Overcurrent stall Integral coefficient
2317 -)))|(% colspan="2" style="width:451px" %)Default|500
2318 -|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000
2319 2319  
2320 -set overcurrent stall Integral coefficient rate.
2321 -
2322 2322  When “free stop” is selected: the inverter prompts Err~*~* and stops directly.
2323 2323  
2324 2324  When "Stop according to stop mode" is selected: the inverter prompts A~*~* and stops according to the stop mode, and prompts ErrXX after stopping.
... ... @@ -2326,22 +2326,29 @@
2326 2326  When “continue running” is selected: the inverter continues to run and prompts A~*~*. For the running frequency, refer to the description of FA.20 and FA.21.
2327 2327  
2328 2328  (% class="table-bordered" %)
2329 -|(% rowspan="2" %)(((
2330 -FA.17
2331 -)))|(((
2332 -Undervoltage setting
2333 -)))|(((
2323 +|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)(((
2324 +Overcurrent stall Integral coefficient
2325 +)))|(% colspan="2" style="width:451px" %)Default|500
2326 +|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000
2327 +
2328 +Set overcurrent stall Integral coefficient rate.
2329 +
2330 +(% class="table-bordered" %)
2331 +|(% rowspan="3" %)(((
2332 +**FA.17**
2333 +)))|(% colspan="2" rowspan="1" %)Instant stop /no-stop mode |(((
2334 2334  Default
2335 2335  )))|(((
2336 -100.0%
2336 +0
2337 2337  )))
2338 -|(((
2338 +|(% colspan="1" rowspan="2" %)(((
2339 2339  Setting range
2340 -)))|(% colspan="2" rowspan="1" %)(((
2341 -60.0%~~140.0%
2340 +)))|(% rowspan="1" %)0|(% colspan="2" rowspan="1" %)(((
2341 +General machine instant stop/no-stop
2342 2342  )))
2343 +|1|(% colspan="2" %)Spinning machine instant stop/no-stop
2343 2343  
2344 -Instantaneous power failure mode selection
2345 +Set the mode of instant stop and no-stop.
2345 2345  
2346 2346  (% class="table-bordered" %)
2347 2347  |(% rowspan="2" %)**FA.18**|Undervoltage setting|Default|100.0%