Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Jim - Content
-
... ... @@ -51,7 +51,7 @@ 51 51 |2|(% colspan="2" %)AI1 52 52 |3|(% colspan="2" %)AI2 53 53 |4|(% colspan="2" %)Reserved 54 -|5|(% colspan="2" %)PULSE setting DI6(Reserved)54 +|5|(% colspan="2" %)PULSE setting(Reserved) 55 55 |6|(% colspan="2" %)Multi-stage speed setting 56 56 |7|(% colspan="2" %)Simple PLC 57 57 |8|(% colspan="2" %)PID ... ... @@ -260,8 +260,6 @@ 260 260 |(% rowspan="2" %)** F0.16**|Carrier Frequency|Default|Model Dependent 261 261 |Setting Range|(% colspan="2" %)0.5kHz~~16.0kHz 262 262 263 -= Carrier Frequency: = 264 - 265 265 This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced. 266 266 267 267 When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases. ... ... @@ -2302,17 +2302,23 @@ 2302 2302 |(% rowspan="9" %)**FA.15**|(% colspan="2" style="width:442px" %)Fault protection action selection 3|(% style="width:451px" %)Default|(% colspan="2" %)00000 2303 2303 |(% rowspan="7" %)Setting range|(% style="width:316px" %)Ones Place|(% colspan="3" style="width:978px" %)User-defined fault 1(Err27) (0~~2,as ones place of FA.13) 2304 2304 |(% style="width:316px" %)Tens Place|(% colspan="3" style="width:978px" %)User-defined fault 2(Err28) (0~~2,as ones place of FA.13) 2305 -|(% style="width:316px" %)Hundreds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13) 2306 -|(% style="width:316px" %)Thousands Place|(% colspan="3" style="width:978px" %)Load loss(Err30) 2303 +|(% style="width:316px" %)Hundr-eds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13) 2304 +|(% style="width:316px" %)Thous-ands Place|(% colspan="3" style="width:978px" %)Load loss(Err30) 2307 2307 |(% style="width:316px" %)0|(% colspan="3" style="width:978px" %)Free stopping 2308 2308 |(% style="width:316px" %)1|(% colspan="3" style="width:978px" %)Stop according to the stop mode 2309 2309 |(% style="width:316px" %)2|(% colspan="3" style="width:978px" %)Decelerate to 7% of the rated frequency of the motor and continue to run, and automatically return to the set frequency if the load is not lost 2310 -| |(% style="width:316px" %)Ten thousands Place|(% colspan="3" style="width:978px" %)((( 2308 +| |(% style="width:316px" %)Ten thous-ands Place|(% colspan="3" style="width:978px" %)((( 2311 2311 PID feedback loss during 2312 2312 2313 2313 Running (Err31) (0~~2,as ones place of FA.13) 2314 2314 ))) 2313 +|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)((( 2314 +Overcurrent stall Integral coefficient 2315 +)))|(% colspan="2" style="width:451px" %)Default|500 2316 +|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000 2315 2315 2318 +set overcurrent stall Integral coefficient rate. 2319 + 2316 2316 When “free stop” is selected: the inverter prompts Err~*~* and stops directly. 2317 2317 2318 2318 When "Stop according to stop mode" is selected: the inverter prompts A~*~* and stops according to the stop mode, and prompts ErrXX after stopping. ... ... @@ -2320,29 +2320,22 @@ 2320 2320 When “continue running” is selected: the inverter continues to run and prompts A~*~*. For the running frequency, refer to the description of FA.20 and FA.21. 2321 2321 2322 2322 (% class="table-bordered" %) 2323 -|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)((( 2324 -Overcurrent stall Integral coefficient 2325 -)))|(% colspan="2" style="width:451px" %)Default|500 2326 -|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000 2327 - 2328 -Set overcurrent stall Integral coefficient rate. 2329 - 2330 -(% class="table-bordered" %) 2331 -|(% rowspan="3" %)((( 2332 -**FA.17** 2333 -)))|(% colspan="2" rowspan="1" %)Instant stop /no-stop mode |((( 2327 +|(% rowspan="2" %)((( 2328 +FA.17 2329 +)))|((( 2330 +Undervoltage setting 2331 +)))|((( 2334 2334 Default 2335 2335 )))|((( 2336 -0 2334 +100.0% 2337 2337 ))) 2338 -|( % colspan="1" rowspan="2" %)(((2336 +|((( 2339 2339 Setting range 2340 -)))|(% rowspan="1" %)0|(%colspan="2" rowspan="1" %)(((2341 - General machine instant stop/no-stop2338 +)))|(% colspan="2" rowspan="1" %)((( 2339 +60.0%~~140.0% 2342 2342 ))) 2343 -|1|(% colspan="2" %)Spinning machine instant stop/no-stop 2344 2344 2345 - Sethemodeofinstantstop andno-stop.2342 +Instantaneous power failure mode selection 2346 2346 2347 2347 (% class="table-bordered" %) 2348 2348 |(% rowspan="2" %)**FA.18**|Undervoltage setting|Default|100.0%