Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -08 Function parameter details
1 +8 Function parameter details
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Jim
Content
... ... @@ -51,7 +51,7 @@
51 51  |2|(% colspan="2" %)AI1
52 52  |3|(% colspan="2" %)AI2
53 53  |4|(% colspan="2" %)Reserved
54 -|5|(% colspan="2" %)PULSE setting DI6(Reserved)
54 +|5|(% colspan="2" %)PULSE setting(Reserved)
55 55  |6|(% colspan="2" %)Multi-stage speed setting
56 56  |7|(% colspan="2" %)Simple PLC
57 57  |8|(% colspan="2" %)PID
... ... @@ -260,8 +260,6 @@
260 260  |(% rowspan="2" %)** F0.16**|Carrier Frequency|Default|Model Dependent
261 261  |Setting Range|(% colspan="2" %)0.5kHz~~16.0kHz
262 262  
263 -= Carrier Frequency: =
264 -
265 265  This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced.
266 266  
267 267  When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases.
... ... @@ -2302,17 +2302,23 @@
2302 2302  |(% rowspan="9" %)**FA.15**|(% colspan="2" style="width:442px" %)Fault protection action selection 3|(% style="width:451px" %)Default|(% colspan="2" %)00000
2303 2303  |(% rowspan="7" %)Setting range|(% style="width:316px" %)Ones Place|(% colspan="3" style="width:978px" %)User-defined fault 1(Err27) (0~~2,as ones place of FA.13)
2304 2304  |(% style="width:316px" %)Tens Place|(% colspan="3" style="width:978px" %)User-defined fault 2(Err28) (0~~2,as ones place of FA.13)
2305 -|(% style="width:316px" %)Hundreds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)
2306 -|(% style="width:316px" %)Thousands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)
2303 +|(% style="width:316px" %)Hundr-eds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)
2304 +|(% style="width:316px" %)Thous-ands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)
2307 2307  |(% style="width:316px" %)0|(% colspan="3" style="width:978px" %)Free stopping
2308 2308  |(% style="width:316px" %)1|(% colspan="3" style="width:978px" %)Stop according to the stop mode
2309 2309  |(% style="width:316px" %)2|(% colspan="3" style="width:978px" %)Decelerate to 7% of the rated frequency of the motor and continue to run, and automatically return to the set frequency if the load is not lost
2310 -| |(% style="width:316px" %)Ten thousands Place|(% colspan="3" style="width:978px" %)(((
2308 +| |(% style="width:316px" %)Ten thous-ands Place|(% colspan="3" style="width:978px" %)(((
2311 2311  PID feedback loss during
2312 2312  
2313 2313  Running (Err31) (0~~2,as ones place of FA.13)
2314 2314  )))
2313 +|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)(((
2314 +Overcurrent stall Integral coefficient
2315 +)))|(% colspan="2" style="width:451px" %)Default|500
2316 +|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000
2315 2315  
2318 +set overcurrent stall Integral coefficient rate.
2319 +
2316 2316  When “free stop” is selected: the inverter prompts Err~*~* and stops directly.
2317 2317  
2318 2318  When "Stop according to stop mode" is selected: the inverter prompts A~*~* and stops according to the stop mode, and prompts ErrXX after stopping.
... ... @@ -2320,29 +2320,22 @@
2320 2320  When “continue running” is selected: the inverter continues to run and prompts A~*~*. For the running frequency, refer to the description of FA.20 and FA.21.
2321 2321  
2322 2322  (% class="table-bordered" %)
2323 -|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)(((
2324 -Overcurrent stall Integral coefficient
2325 -)))|(% colspan="2" style="width:451px" %)Default|500
2326 -|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000
2327 -
2328 -Set overcurrent stall Integral coefficient rate.
2329 -
2330 -(% class="table-bordered" %)
2331 -|(% rowspan="3" %)(((
2332 -**FA.17**
2333 -)))|(% colspan="2" rowspan="1" %)Instant stop /no-stop mode |(((
2327 +|(% rowspan="2" %)(((
2328 +FA.17
2329 +)))|(((
2330 +Undervoltage setting
2331 +)))|(((
2334 2334  Default
2335 2335  )))|(((
2336 -0
2334 +100.0%
2337 2337  )))
2338 -|(% colspan="1" rowspan="2" %)(((
2336 +|(((
2339 2339  Setting range
2340 -)))|(% rowspan="1" %)0|(% colspan="2" rowspan="1" %)(((
2341 -General machine instant stop/no-stop
2338 +)))|(% colspan="2" rowspan="1" %)(((
2339 +60.0%~~140.0%
2342 2342  )))
2343 -|1|(% colspan="2" %)Spinning machine instant stop/no-stop
2344 2344  
2345 -Set the mode of instant stop and no-stop.
2342 +Instantaneous power failure mode selection
2346 2346  
2347 2347  (% class="table-bordered" %)
2348 2348  |(% rowspan="2" %)**FA.18**|Undervoltage setting|Default|100.0%