... ... @@ -54,7 +54,7 @@
54 54  |2|(% colspan="2" %)AI1
55 55  |3|(% colspan="2" %)AI2
56 56  |4|(% colspan="2" %)Reserved
57 -|5|(% colspan="2" %)PULSE setting DI6(Reserved)
57 +|5|(% colspan="2" %)PULSE setting DI6
58 58  |6|(% colspan="2" %)Multi-stage speed setting
59 59  |7|(% colspan="2" %)Simple PLC
60 60  |8|(% colspan="2" %)PID
... ... @@ -86,12 +86,8 @@
86 86  
87 87  The set frequency is given by the terminal pulse.
88 88  
89 -Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~100kHz.
89 +Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~20kHz.
90 90  
91 -{{info}}
92 -**✎**Note: Pulse reference can only be input from the multi-function input terminal, __**requires custom control board development.**__
93 -{{/info}}
94 -
95 95  **6: **Multi-stage speed
96 96  
97 97  Select multi-stage speed operation mode. Need to set the F5 group "input terminals" and FD group "multi-stage speed and PLC" parameters to determine the corresponding relationship between the given signal and the given frequency.
... ... @@ -261,12 +261,12 @@
261 261  
262 262  Select the running state of the AC drive when the set frequency is lower than the lower limit frequency. In order to prevent the motor from running at low speed for a long time, this function can be used to choose to stop.
263 263  
260 +== Carrier frequency ==
261 +
264 264  (% class="table-bordered" %)
265 265  |(% rowspan="2" style="width:139px" %)** F0.16**|(% style="width:680px" %)Carrier Frequency|(% style="width:429px" %)Default|(% style="width:204px" %)Model Dependent
266 266  |(% style="width:680px" %)Setting Range|(% colspan="2" style="width:633px" %)0.5kHz~~16.0kHz
267 267  
268 -= Carrier Frequency: =
269 -
270 270  This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced.
271 271  
272 272  When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases.