Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 25.1
edited by Theodore Xu
on 2025/02/21 14:13
on 2025/02/21 14:13
Change comment:
There is no comment for this version
To version 18.1
edited by Theodore Xu
on 2023/11/24 17:08
on 2023/11/24 17:08
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 -= F0 group basic parameters = 1 += 1 F0 group basic parameters = 2 2 3 3 (% class="table-bordered" %) 4 4 |(% rowspan="3" %)**F0.00**|(% colspan="2" %)Motor control mode|Default|0 ... ... @@ -54,7 +54,7 @@ 54 54 |2|(% colspan="2" %)AI1 55 55 |3|(% colspan="2" %)AI2 56 56 |4|(% colspan="2" %)Reserved 57 -|5|(% colspan="2" %)PULSE setting DI6 57 +|5|(% colspan="2" %)PULSE setting DI6(Reserved) 58 58 |6|(% colspan="2" %)Multi-stage speed setting 59 59 |7|(% colspan="2" %)Simple PLC 60 60 |8|(% colspan="2" %)PID ... ... @@ -86,8 +86,10 @@ 86 86 87 87 The set frequency is given by the terminal pulse. 88 88 89 -Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~ 20kHz.89 +Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~100kHz. 90 90 91 +Note: Pulse reference can only be input from the multi-function input terminal, __**requires custom control board development.**__ 92 + 91 91 **6: **Multi-stage speed 92 92 93 93 Select multi-stage speed operation mode. Need to set the F5 group "input terminals" and FD group "multi-stage speed and PLC" parameters to determine the corresponding relationship between the given signal and the given frequency. ... ... @@ -257,12 +257,12 @@ 257 257 258 258 Select the running state of the AC drive when the set frequency is lower than the lower limit frequency. In order to prevent the motor from running at low speed for a long time, this function can be used to choose to stop. 259 259 260 -== Carrier frequency == 261 - 262 262 (% class="table-bordered" %) 263 263 |(% rowspan="2" style="width:139px" %)** F0.16**|(% style="width:680px" %)Carrier Frequency|(% style="width:429px" %)Default|(% style="width:204px" %)Model Dependent 264 264 |(% style="width:680px" %)Setting Range|(% colspan="2" style="width:633px" %)0.5kHz~~16.0kHz 265 265 266 += Carrier Frequency: = 267 + 266 266 This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced. 267 267 268 268 When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases. ... ... @@ -390,7 +390,7 @@ 390 390 391 391 The decimal place of the control frequency related instruction, the default is 2 decimal places. After the parameter is set, the decimal place of the parameter associated with the frequency is automatically adjusted. This parameter is not affected by F0.20. 392 392 393 -= F1 group start & stop control = 395 += 2 F1 group start & stop control = 394 394 395 395 (% class="table-bordered" %) 396 396 |(% rowspan="4" %)**F1.00**|(% colspan="2" %)Starting mode|Default|0 ... ... @@ -550,7 +550,7 @@ 550 550 551 551 Setting whether the AC drive has output when running frequency is 0 552 552 553 -= F2 group motor parameters = 555 += 3 F2 group motor parameters = 554 554 555 555 (% class="table-bordered" %) 556 556 |(% rowspan="5" %)**F2.00**|(% colspan="2" %)Motor type selection|Default|0 ... ... @@ -644,9 +644,7 @@ 644 644 645 645 When F2.11 is set to 1 or 2 and then press the ENT key, "TUNE" is displayed and flashes at this time, and then press the RUN key to start parameter tuning, and the displayed "TUNE" stops flashing at this time. When the tuning is over, the display returns to the stop state interface. During the tuning process, you can press the STOP button to stop tuning. When the tuning is completed, the value of F2.11 automatically returns to 0. 646 646 647 -{{info}} 648 648 **✎Note: Tuning can only be effective in keyboard control mode, and the factory default value of acceleration and deceleration time is recommended.** 649 -{{/info}} 650 650 651 651 (% class="table-bordered" %) 652 652 |(% rowspan="3" %)**F2.12**|(% colspan="2" %)G/P type selection|Default|Model dependent ... ... @@ -665,7 +665,7 @@ 665 665 666 666 The main and auxiliary winding currents can be changed by adjusting the single-phase motor turns ratio. Generally, reducing the single-phase motor turns ratio can increase the main winding current, reduce the auxiliary winding current, and reduce the motor heating (only effective when F2.00 = 3) . 667 667 668 -= F3 group vector control parameters = 668 += 4 F3 group vector control parameters = 669 669 670 670 F3 group function codes are only valid in vector control mode, that is, it is valid when F0.00=0, and it is invalid when F0.00=1. 671 671 ... ... @@ -802,7 +802,7 @@ 802 802 803 803 During startup, torque command 1 = F3.11 * F3.24 / 100; after maintaining time F3.25 seconds, it will be restored to torque command 2 = F3.11; torque command 1/2 switching requires torque acceleration and deceleration time F3.14/F3.15. 804 804 805 -= F4 group v/f control parameters = 805 += 5 F4 group v/f control parameters = 806 806 807 807 This group of function codes is only valid for V/F control (F0.00=1), and invalid for vector control. 808 808 ... ... @@ -971,7 +971,7 @@ 971 971 972 972 According to the actual use, select the situation where the AVR function is enabled. 973 973 974 -= F5 group input terminals = 974 += 6 F5 group input terminals = 975 975 976 976 The standard unit of the VB series inverter has 6 multi-function digital input terminals and 2 analog input terminals. 977 977 ... ... @@ -1208,7 +1208,7 @@ 1208 1208 1209 1209 Low Level:The connection between DI terminal and COM is invalid, while disconnection is valid. 1210 1210 1211 -= F6 group output terminals = 1211 += 7 F6 group output terminals = 1212 1212 1213 1213 The standard unit of VB series inverter has 2 multi-function relay output terminals, 1 FM terminal and 2 multi-function analog output terminals. 1214 1214 ... ... @@ -1314,8 +1314,9 @@ 1314 1314 |11|Count value|0~~Maximum count value 1315 1315 |12|Communication setting|-10000~~10000 1316 1316 |13|Motor Speed|0~~Rotation speed corresponding to maximum output frequency 1317 -|14|Output Current|0-1000A, as 0-10V 1318 -|15|Output Voltage|0-1000V, as 0-10V 1317 +|14|Output Current|0-1000A,as 0-10V 1318 + 0-1000V,as 0-10V 1319 +|15|Output Voltage|0.0V~~1000.0V 1319 1319 1320 1320 (% class="table-bordered" %) 1321 1321 |(% rowspan="2" %)**F6.14**|FMP output maximum frequency|Default|50.00kHz ... ... @@ -1467,7 +1467,7 @@ 1467 1467 1468 1468 Set the timer setting time 1469 1469 1470 -= F7 group keypad display = 1471 += 8 F7 group keypad display = 1471 1471 1472 1472 (% class="table-bordered" %) 1473 1473 |(% rowspan="4" %)**F7.00**|(% colspan="2" %)LCD keypad parameter copy|Default|0 ... ... @@ -1678,7 +1678,7 @@ 1678 1678 |(% rowspan="2" %)**F7.15**|Performance software version|Default|- 1679 1679 |Setting range|(% colspan="2" %)- 1680 1680 1681 -= F8 group auxiliary functions = 1682 += 9 F8 group auxiliary functions = 1682 1682 1683 1683 (% class="table-bordered" %) 1684 1684 |(% rowspan="2" %)**F8.00**|JOG running frequency|Default|2.00Hz ... ... @@ -1978,7 +1978,7 @@ 1978 1978 1979 1979 Enabling the fast current limiting function can minimize the inverter's overcurrent fault and protect the inverter from uninterrupted operation. After entering the fast current-limiting state for a period of time, a fast current-limiting fault (Err40) will be reported, indicating that the inverter is overloaded. Please refer to the handling of Err10. 1980 1980 1981 -= F9 group pid function of process control = 1982 += 10 F9 group pid function of process control = 1982 1982 1983 1983 PID control is a common method used in process control. It adjusts the output frequency of the inverter by performing proportional, integral, and differential calculations on the difference between the feedback signal of the controlled quantity and the target quantity signal to form a negative feedback system. The controlled amount is stable at the target amount. It is suitable for process control such as flow control, pressure control and temperature control. The basic control block diagram is as follows: 1984 1984 ... ... @@ -2183,7 +2183,7 @@ 2183 2183 2184 2184 Figure 6-10-2 PID sleep and wake-up timing diagram 2185 2185 2186 -= FA group faults & protection = 2187 += 11 FA group faults & protection = 2187 2187 2188 2188 (% class="table-bordered" %) 2189 2189 |(% rowspan="3" %)**FA.00**|Motor overload protection selection|Default|1 ... ... @@ -2391,7 +2391,7 @@ 2391 2391 2392 2392 This function means that the inverter will not stop when the power is cut instantaneously. In the case of an instantaneous power failure or a sudden voltage drop, the inverter will reduce its output speed, and compensate for the voltage drop by feeding back energy through the load to keep the inverter running in a short time. 2393 2393 2394 -If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When busexceedsFA.23andgreater2395 +If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When the stop action judgment voltage (FA.25) represents the voltage, and the duration is maintained for the momentary stop and non-stop voltage rise judgment time (FA.24), the inverter resumes the set frequency operation; otherwise the inverter will continue to reduce the operating frequency to Stop at 0 o'clock. Instantaneous stop non-stop function if shown. 2395 2395 2396 2396 The deceleration time of instantaneous power failure is too long, the load feedback energy is small, and the low voltage can not be effectively compensated; the deceleration time is too short, the load feedback energy is large, which will cause overvoltage protection. Please adjust the deceleration time appropriately according to the load inertia and the weight of the load. 2397 2397 ... ... @@ -2418,7 +2418,7 @@ 2418 2418 2419 2419 Note: The function code display data is H.xxx, where H. means hexadecimal data. 2420 2420 2421 -= FB group frequency swing, length fixing and counting = 2422 += 12 FB group frequency swing, length fixing and counting = 2422 2422 2423 2423 The swing frequency function is suitable for textile, chemical fiber and other industries and occasions that require traverse and winding functions. 2424 2424 ... ... @@ -2505,7 +2505,7 @@ 2505 2505 2506 2506 Figure 6-12-2 Schematic diagram of set count value given and designated count value given 2507 2507 2508 -= FC group communication parameters = 2509 += 13 FC group communication parameters = 2509 2509 2510 2510 (% class="table-bordered" %) 2511 2511 |(% rowspan="2" %)**FC.00**|Local address|Default|1 ... ... @@ -2556,7 +2556,7 @@ 2556 2556 2557 2557 Used to determine the output unit of the current value when the communication reads the output current. 2558 2558 2559 -= FD group muti-stage speed and simple plc functions = 2560 += 14 FD group muti-stage speed and simple plc functions = 2560 2560 2561 2561 The simple PLC function is that the inverter has a programmable controller (PLC) built in to complete automatic control of multi-segment frequency logic. The running time, running direction and running frequency can be set to meet the technological requirements. This series of inverters can realize 16-speed change control, and there are 4 kinds of acceleration and deceleration time for selection. When the set PLC completes a cycle, an ON signal can be output from the multifunctional digital output terminals DO1 and DO2 or multifunctional relay 1 and relay 2. See F1.02~~F1.05 for details. When the frequency source selection F0.07, F0.03, F0.04 is determined as the multi-speed operation mode, it is necessary to set FD.00~~FD.15 to determine its characteristics. 2562 2562 ... ... @@ -2715,7 +2715,7 @@ 2715 2715 2716 2716 This parameter determines the target quantity given channel of multi-speed 0. 2717 2717 2718 -= FE group user password management = 2719 += 15 FE group user password management = 2719 2719 2720 2720 (% class="table-bordered" %) 2721 2721 |(% rowspan="2" %)**FE.00**|User password|Default|0