Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Mora
Content
... ... @@ -54,7 +54,7 @@
54 54  |2|(% colspan="2" %)AI1
55 55  |3|(% colspan="2" %)AI2
56 56  |4|(% colspan="2" %)Reserved
57 -|5|(% colspan="2" %)PULSE setting DI6
57 +|5|(% colspan="2" %)PULSE setting DI6(Reserved)
58 58  |6|(% colspan="2" %)Multi-stage speed setting
59 59  |7|(% colspan="2" %)Simple PLC
60 60  |8|(% colspan="2" %)PID
... ... @@ -86,8 +86,12 @@
86 86  
87 87  The set frequency is given by the terminal pulse.
88 88  
89 -Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~20kHz.
89 +Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~100kHz.
90 90  
91 +{{info}}
92 +**✎**Note: Pulse reference can only be input from the multi-function input terminal, __**requires custom control board development.**__
93 +{{/info}}
94 +
91 91  **6: **Multi-stage speed
92 92  
93 93  Select multi-stage speed operation mode. Need to set the F5 group "input terminals" and FD group "multi-stage speed and PLC" parameters to determine the corresponding relationship between the given signal and the given frequency.
... ... @@ -257,12 +257,12 @@
257 257  
258 258  Select the running state of the AC drive when the set frequency is lower than the lower limit frequency. In order to prevent the motor from running at low speed for a long time, this function can be used to choose to stop.
259 259  
260 -== Carrier frequency ==
261 -
262 262  (% class="table-bordered" %)
263 263  |(% rowspan="2" style="width:139px" %)** F0.16**|(% style="width:680px" %)Carrier Frequency|(% style="width:429px" %)Default|(% style="width:204px" %)Model Dependent
264 264  |(% style="width:680px" %)Setting Range|(% colspan="2" style="width:633px" %)0.5kHz~~16.0kHz
265 265  
268 += Carrier Frequency: =
269 +
266 266  This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced.
267 267  
268 268  When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases.
... ... @@ -1314,8 +1314,9 @@
1314 1314  |11|Count value|0~~Maximum count value
1315 1315  |12|Communication setting|-10000~~10000
1316 1316  |13|Motor Speed|0~~Rotation speed corresponding to maximum output frequency
1317 -|14|Output Current|0-1000A, as 0-10V
1318 -|15|Output Voltage|0-1000V, as 0-10V
1321 +|14|Output Current|0-1000A,as 0-10V
1322 + 0-1000V,as 0-10V
1323 +|15|Output Voltage|0.0V~~1000.0V
1319 1319  
1320 1320  (% class="table-bordered" %)
1321 1321  |(% rowspan="2" %)**F6.14**|FMP output maximum frequency|Default|50.00kHz   
... ... @@ -2391,7 +2391,7 @@
2391 2391  
2392 2392  This function means that the inverter will not stop when the power is cut instantaneously. In the case of an instantaneous power failure or a sudden voltage drop, the inverter will reduce its output speed, and compensate for the voltage drop by feeding back energy through the load to keep the inverter running in a short time.
2393 2393  
2394 -If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When the bus voltage exceeds FA.2and the duration is greater than FA.24, the inverter resumes the set frequency operation; otherwise the inverter will continue to reduce the operating frequency to Stop at 0 o'clock. Instantaneous stop non-stop function if shown.
2399 +If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When the stop action judgment voltage (FA.25) represents the voltage, and the duration is maintained for the momentary stop and non-stop voltage rise judgment time (FA.24), the inverter resumes the set frequency operation; otherwise the inverter will continue to reduce the operating frequency to Stop at 0 o'clock. Instantaneous stop non-stop function if shown.
2395 2395  
2396 2396  The deceleration time of instantaneous power failure is too long, the load feedback energy is small, and the low voltage can not be effectively compensated; the deceleration time is too short, the load feedback energy is large, which will cause overvoltage protection. Please adjust the deceleration time appropriately according to the load inertia and the weight of the load.
2397 2397