Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 25.1
edited by Theodore Xu
on 2025/02/21 14:13
on 2025/02/21 14:13
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Mora - Content
-
... ... @@ -54,7 +54,7 @@ 54 54 |2|(% colspan="2" %)AI1 55 55 |3|(% colspan="2" %)AI2 56 56 |4|(% colspan="2" %)Reserved 57 -|5|(% colspan="2" %)PULSE setting DI6 57 +|5|(% colspan="2" %)PULSE setting DI6(Reserved) 58 58 |6|(% colspan="2" %)Multi-stage speed setting 59 59 |7|(% colspan="2" %)Simple PLC 60 60 |8|(% colspan="2" %)PID ... ... @@ -86,8 +86,12 @@ 86 86 87 87 The set frequency is given by the terminal pulse. 88 88 89 -Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~ 20kHz.89 +Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~100kHz. 90 90 91 +{{info}} 92 +**✎**Note: Pulse reference can only be input from the multi-function input terminal, __**requires custom control board development.**__ 93 +{{/info}} 94 + 91 91 **6: **Multi-stage speed 92 92 93 93 Select multi-stage speed operation mode. Need to set the F5 group "input terminals" and FD group "multi-stage speed and PLC" parameters to determine the corresponding relationship between the given signal and the given frequency. ... ... @@ -257,12 +257,12 @@ 257 257 258 258 Select the running state of the AC drive when the set frequency is lower than the lower limit frequency. In order to prevent the motor from running at low speed for a long time, this function can be used to choose to stop. 259 259 260 -== Carrier frequency == 261 - 262 262 (% class="table-bordered" %) 263 263 |(% rowspan="2" style="width:139px" %)** F0.16**|(% style="width:680px" %)Carrier Frequency|(% style="width:429px" %)Default|(% style="width:204px" %)Model Dependent 264 264 |(% style="width:680px" %)Setting Range|(% colspan="2" style="width:633px" %)0.5kHz~~16.0kHz 265 265 268 += Carrier Frequency: = 269 + 266 266 This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced. 267 267 268 268 When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases. ... ... @@ -1314,8 +1314,9 @@ 1314 1314 |11|Count value|0~~Maximum count value 1315 1315 |12|Communication setting|-10000~~10000 1316 1316 |13|Motor Speed|0~~Rotation speed corresponding to maximum output frequency 1317 -|14|Output Current|0-1000A, as 0-10V 1318 -|15|Output Voltage|0-1000V, as 0-10V 1321 +|14|Output Current|0-1000A,as 0-10V 1322 + 0-1000V,as 0-10V 1323 +|15|Output Voltage|0.0V~~1000.0V 1319 1319 1320 1320 (% class="table-bordered" %) 1321 1321 |(% rowspan="2" %)**F6.14**|FMP output maximum frequency|Default|50.00kHz ... ... @@ -2391,7 +2391,7 @@ 2391 2391 2392 2392 This function means that the inverter will not stop when the power is cut instantaneously. In the case of an instantaneous power failure or a sudden voltage drop, the inverter will reduce its output speed, and compensate for the voltage drop by feeding back energy through the load to keep the inverter running in a short time. 2393 2393 2394 -If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When busexceedsFA.23andgreater2399 +If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When the stop action judgment voltage (FA.25) represents the voltage, and the duration is maintained for the momentary stop and non-stop voltage rise judgment time (FA.24), the inverter resumes the set frequency operation; otherwise the inverter will continue to reduce the operating frequency to Stop at 0 o'clock. Instantaneous stop non-stop function if shown. 2395 2395 2396 2396 The deceleration time of instantaneous power failure is too long, the load feedback energy is small, and the low voltage can not be effectively compensated; the deceleration time is too short, the load feedback energy is large, which will cause overvoltage protection. Please adjust the deceleration time appropriately according to the load inertia and the weight of the load. 2397 2397