... ... @@ -1314,8 +1314,9 @@
1314 1314  |11|Count value|0~~Maximum count value
1315 1315  |12|Communication setting|-10000~~10000
1316 1316  |13|Motor Speed|0~~Rotation speed corresponding to maximum output frequency
1317 -|14|Output Current|0-1000A, as 0-10V
1318 -|15|Output Voltage|0-1000V, as 0-10V
1317 +|14|Output Current|0-1000A,as 0-10V
1318 + 0-1000V,as 0-10V
1319 +|15|Output Voltage|0.0V~~1000.0V
1319 1319  
1320 1320  (% class="table-bordered" %)
1321 1321  |(% rowspan="2" %)**F6.14**|FMP output maximum frequency|Default|50.00kHz   
... ... @@ -2391,7 +2391,7 @@
2391 2391  
2392 2392  This function means that the inverter will not stop when the power is cut instantaneously. In the case of an instantaneous power failure or a sudden voltage drop, the inverter will reduce its output speed, and compensate for the voltage drop by feeding back energy through the load to keep the inverter running in a short time.
2393 2393  
2394 -If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When the bus voltage exceeds FA.2and the duration is greater than FA.24, the inverter resumes the set frequency operation; otherwise the inverter will continue to reduce the operating frequency to Stop at 0 o'clock. Instantaneous stop non-stop function if shown.
2395 +If the instantaneous stop non-stop function selection is valid, when the bus voltage is lower than the voltage indicated by the instantaneous stop non-stop action judgment voltage (FA.25), the inverter will decelerate according to the instantaneous stop action selection. When the stop action judgment voltage (FA.25) represents the voltage, and the duration is maintained for the momentary stop and non-stop voltage rise judgment time (FA.24), the inverter resumes the set frequency operation; otherwise the inverter will continue to reduce the operating frequency to Stop at 0 o'clock. Instantaneous stop non-stop function if shown.
2395 2395  
2396 2396  The deceleration time of instantaneous power failure is too long, the load feedback energy is small, and the low voltage can not be effectively compensated; the deceleration time is too short, the load feedback energy is large, which will cause overvoltage protection. Please adjust the deceleration time appropriately according to the load inertia and the weight of the load.
2397 2397