Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 5.1
edited by Jim(Forgotten)
on 2023/04/13 09:47
on 2023/04/13 09:47
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 8Function parameter details1 +2.7 Function parameter details - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -VFD.VB AC Drive User Manual.WebHome 1 +VFD.2\. User Manual.WECON VB AC Drive User Manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.admin - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= 1 F0 group basic parameters = 1 += 6.1 F0 group basic parameters = 2 2 3 3 (% class="table-bordered" %) 4 4 |(% rowspan="3" %)**F0.00**|(% colspan="2" %)Motor control mode|Default|0 ... ... @@ -59,13 +59,13 @@ 59 59 60 60 Select the main source of the AC drive’s input frequency. There are 10 main frequency sources: 61 61 62 - **0:**Digital setting (non-retentive at power failure)62 +0: Digital setting (non-retentive at power failure) 63 63 64 64 The initial value is 0. The frequency can be increased or decreased by the pulse knob, and the set frequency value of the inverter can be changed by the ▲/▼ keys of the keyboard (or UP and DOWN of the multi-function input terminals). 65 65 66 66 Non-retentive means that after the AC drive is powered off, the set frequency value will be restored to 0; it will be cleared after switching as the frequency source, so this parameter should not be the object of frequency source switching. 67 67 68 - **1:**Digital setting (retentive at power failure)68 +1: Digital setting (retentive at power failure) 69 69 70 70 The initial value is the value of F0.08 "Keypad setting frequency". 71 71 ... ... @@ -73,33 +73,27 @@ 73 73 74 74 Retentive means that when the AC drive is powered on again after power failure, the set frequency is the value before the last power failure (note that it is used in conjunction with F0.23). 75 75 76 - **2:**AI176 +2: AI1 77 77 78 - **3:**AI278 +3: AI2 79 79 80 80 Means that the frequency is determined by the analog input terminal. The standard unit provides 2 analog input terminals (AI1, AI2), among which AI1 is 0V~~10V voltage input, AI2 can be 0V~~10V voltage input, or 4mA~~20mA current input, Selected by jumper J8 on the control board. 81 81 82 - **4/5:**PULSE setting(Reserved)82 +4/5: Reserved 83 83 84 - Theset frequencyisivenby the terminal pulse.84 +6: Multi-stage speed 85 85 86 -Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~100kHz. 87 - 88 -Note: Pulse reference can only be input from the multi-function input terminal, __**requires custom control board development.**__ 89 - 90 -**6: **Multi-stage speed 91 - 92 92 Select multi-stage speed operation mode. Need to set the F5 group "input terminals" and FD group "multi-stage speed and PLC" parameters to determine the corresponding relationship between the given signal and the given frequency. 93 93 94 - **7:**Simple PLC88 +7: Simple PLC 95 95 96 96 Select simple PLC mode. When the frequency source is simple PLC, you need to set the FD group "multi-speed and PLC" parameters to determine the set frequency. 97 97 98 - **8:**PID92 +8: PID 99 99 100 100 Select process PID control. At this time, you need to set the F9 group "PID function of process control ". The running frequency of the inverter is the frequency value after PID action. For the meaning of PID given source, given amount, feedback source, etc., please refer to the introduction of "PID Function of process control" in F9 group. 101 101 102 - **9:**Communication setting96 +9: Communication setting 103 103 104 104 Means that the main frequency source is given by the upper machine through communication. 105 105 ... ... @@ -387,7 +387,7 @@ 387 387 388 388 The decimal place of the control frequency related instruction, the default is 2 decimal places. After the parameter is set, the decimal place of the parameter associated with the frequency is automatically adjusted. This parameter is not affected by F0.20. 389 389 390 -= 2 F1 group start & stop control = 384 += 6.2 F1 group start & stop control = 391 391 392 392 (% class="table-bordered" %) 393 393 |(% rowspan="4" %)**F1.00**|(% colspan="2" %)Starting mode|Default|0 ... ... @@ -547,7 +547,7 @@ 547 547 548 548 Setting whether the AC drive has output when running frequency is 0 549 549 550 -= 3 F2 group motor parameters = 544 += 6.3 F2 group motor parameters = 551 551 552 552 (% class="table-bordered" %) 553 553 |(% rowspan="5" %)**F2.00**|(% colspan="2" %)Motor type selection|Default|0 ... ... @@ -660,7 +660,7 @@ 660 660 661 661 The main and auxiliary winding currents can be changed by adjusting the single-phase motor turns ratio. Generally, reducing the single-phase motor turns ratio can increase the main winding current, reduce the auxiliary winding current, and reduce the motor heating (only effective when F2.00 = 3) . 662 662 663 -= 4 F3 group vector control parameters = 657 += 6.4 F3 group vector control parameters = 664 664 665 665 F3 group function codes are only valid in vector control mode, that is, it is valid when F0.00=0, and it is invalid when F0.00=1. 666 666 ... ... @@ -797,7 +797,7 @@ 797 797 798 798 During startup, torque command 1 = F3.11 * F3.24 / 100; after maintaining time F3.25 seconds, it will be restored to torque command 2 = F3.11; torque command 1/2 switching requires torque acceleration and deceleration time F3.14/F3.15. 799 799 800 -= 5 F4 group v/f control parameters = 794 += 6.5 F4 group v/f control parameters = 801 801 802 802 This group of function codes is only valid for V/F control (F0.00=1), and invalid for vector control. 803 803 ... ... @@ -966,7 +966,7 @@ 966 966 967 967 According to the actual use, select the situation where the AVR function is enabled. 968 968 969 -= 6 F5 group input terminals = 963 += 6.6 F5 group input terminals = 970 970 971 971 The standard unit of the VB series inverter has 6 multi-function digital input terminals and 2 analog input terminals. 972 972 ... ... @@ -1101,7 +1101,7 @@ 1101 1101 1102 1102 0: Two-line mode 1: This mode is the most commonly used two-line mode. The FWD and REV terminal commands determine the forward and reverse of the motor. 1103 1103 1104 -1: Two-wire mode 2: FWDis the enable terminal when using this mode. The direction is determined by the state of theREV.1098 +1: Two-wire mode 2: REV is the enable terminal when using this mode. The direction is determined by the state of the FWD. 1105 1105 1106 1106 2: Three-line mode 1: This mode Din is the enable terminal, and the direction is controlled by FWD and REV respectively. 1107 1107 ... ... @@ -1208,7 +1208,7 @@ 1208 1208 1209 1209 Low Level:The connection between DI terminal and COM is invalid, while disconnection is valid. 1210 1210 1211 -= 7 F6 group output terminals = 1205 += 6.7 F6 group output terminals = 1212 1212 1213 1213 The standard unit of VB series inverter has 2 multi-function relay output terminals, 1 FM terminal and 2 multi-function analog output terminals. 1214 1214 ... ... @@ -1462,7 +1462,7 @@ 1462 1462 1463 1463 For the second output, the parameter setting method is the same as F6.28~~F6.32. 1464 1464 1465 -= 8 F7 group keypad display = 1459 += 6.8 F7 group keypad display = 1466 1466 1467 1467 (% class="table-bordered" %) 1468 1468 |(% rowspan="4" %)**F7.00**|(% colspan="2" %)LCD keypad parameter copy|Default|0 ... ... @@ -1673,7 +1673,7 @@ 1673 1673 |(% rowspan="2" %)**F7.15**|Performance software version|Default|- 1674 1674 |Setting range|(% colspan="2" %)- 1675 1675 1676 -= 9 F8 group auxiliary functions = 1670 += 6.9 F8 group auxiliary functions = 1677 1677 1678 1678 (% class="table-bordered" %) 1679 1679 |(% rowspan="2" %)**F8.00**|JOG running frequency|Default|2.00Hz ... ... @@ -1973,7 +1973,7 @@ 1973 1973 1974 1974 Enabling the fast current limiting function can minimize the inverter's overcurrent fault and protect the inverter from uninterrupted operation. After entering the fast current-limiting state for a period of time, a fast current-limiting fault (Err40) will be reported, indicating that the inverter is overloaded. Please refer to the handling of Err10. 1975 1975 1976 -= 10 F9 group pid function of process control = 1970 += 6.10 F9 group pid function of process control = 1977 1977 1978 1978 PID control is a common method used in process control. It adjusts the output frequency of the inverter by performing proportional, integral, and differential calculations on the difference between the feedback signal of the controlled quantity and the target quantity signal to form a negative feedback system. The controlled amount is stable at the target amount. It is suitable for process control such as flow control, pressure control and temperature control. The basic control block diagram is as follows: 1979 1979 ... ... @@ -2175,8 +2175,9 @@ 2175 2175 2176 2176 Figure 6-10-2 PID sleep and wake-up timing diagram 2177 2177 2178 -= 11 FA group faults & protection = 2179 2179 2173 += 6.11 FA group faults & protection = 2174 + 2180 2180 (% class="table-bordered" %) 2181 2181 |(% rowspan="3" %)**FA.00**|Motor overload protection selection|Default|1 2182 2182 |(% rowspan="2" %)Setting range|0|Disabled ... ... @@ -2409,7 +2409,7 @@ 2409 2409 2410 2410 Note: The function code display data is H.xxx, where H. means hexadecimal data. 2411 2411 2412 -= 12 FB group frequency swing, length fixing and counting = 2407 += 6.12 FB group frequency swing, length fixing and counting = 2413 2413 2414 2414 The swing frequency function is suitable for textile, chemical fiber and other industries and occasions that require traverse and winding functions. 2415 2415 ... ... @@ -2496,7 +2496,7 @@ 2496 2496 2497 2497 Figure 6-12-2 Schematic diagram of set count value given and designated count value given 2498 2498 2499 -= 13 FC group communication parameters = 2494 += 6.13 FC group communication parameters = 2500 2500 2501 2501 (% class="table-bordered" %) 2502 2502 |(% rowspan="2" %)**FC.00**|Local address|Default|1 ... ... @@ -2547,7 +2547,7 @@ 2547 2547 2548 2548 Used to determine the output unit of the current value when the communication reads the output current. 2549 2549 2550 -= 14 FD group muti-stage speed and simple plc functions = 2545 += 6.14 FD group muti-stage speed and simple plc functions = 2551 2551 2552 2552 The simple PLC function is that the inverter has a programmable controller (PLC) built in to complete automatic control of multi-segment frequency logic. The running time, running direction and running frequency can be set to meet the technological requirements. This series of inverters can realize 16-speed change control, and there are 4 kinds of acceleration and deceleration time for selection. When the set PLC completes a cycle, an ON signal can be output from the multifunctional digital output terminals DO1 and DO2 or multifunctional relay 1 and relay 2. See F1.02~~F1.05 for details. When the frequency source selection F0.07, F0.03, F0.04 is determined as the multi-speed operation mode, it is necessary to set FD.00~~FD.15 to determine its characteristics. 2553 2553 ... ... @@ -2706,7 +2706,7 @@ 2706 2706 2707 2707 This parameter determines the target quantity given channel of multi-speed 0. 2708 2708 2709 -= 15 FE group user password management = 2704 += 6.15 FE group user password management = 2710 2710 2711 2711 (% class="table-bordered" %) 2712 2712 |(% rowspan="2" %)**FE.00**|User password|Default|0