Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 7.1
edited by Jim(Forgotten)
on 2023/04/13 09:56
on 2023/04/13 09:56
Change comment:
There is no comment for this version
To version 9.1
edited by Jim(Forgotten)
on 2023/04/17 10:29
on 2023/04/17 10:29
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -51,7 +51,7 @@ 51 51 |2|(% colspan="2" %)AI1 52 52 |3|(% colspan="2" %)AI2 53 53 |4|(% colspan="2" %)Reserved 54 -|5|(% colspan="2" %)Reserved 54 +|5|(% colspan="2" %)PULSE setting(Reserved) 55 55 |6|(% colspan="2" %)Multi-stage speed setting 56 56 |7|(% colspan="2" %)Simple PLC 57 57 |8|(% colspan="2" %)PID ... ... @@ -79,7 +79,7 @@ 79 79 80 80 Means that the frequency is determined by the analog input terminal. The standard unit provides 2 analog input terminals (AI1, AI2), among which AI1 is 0V~~10V voltage input, AI2 can be 0V~~10V voltage input, or 4mA~~20mA current input, Selected by jumper J8 on the control board. 81 81 82 -** 4/5: **PULSE setting(Reserved)82 +**5: **PULSE setting(Reserved) 83 83 84 84 The set frequency is given by the terminal pulse. 85 85 ... ... @@ -1101,18 +1101,27 @@ 1101 1101 1102 1102 0: Two-line mode 1: This mode is the most commonly used two-line mode. The FWD and REV terminal commands determine the forward and reverse of the motor. 1103 1103 1104 +[[image:1681697850903-377.png||height="282" width="633"]] 1105 + 1104 1104 1: Two-wire mode 2: FWD is the enable terminal when using this mode. The direction is determined by the state of the REV. 1105 1105 1106 - 2: Three-linemode 1: This mode Din is the enableterminal, and the direction is controlled by FWD and REV respectively.1108 +[[image:1681697969422-504.png]] 1107 1107 1108 - Butthepulse isvalid,it mustbecompletedbydisconnectingtheDin terminalsignalwhen stopping.1110 +2: Three-line mode 1: This mode Din(function code 3) is the enable terminal, and the direction is controlled by FWD and REV respectively. 1109 1109 1112 +DIN is pulse effective, user need to disconnect the Din terminal signal when stop. 1113 + 1110 1110 Din is the multifunctional input terminal of DI1~~DI6. At this time, the corresponding terminal function should be defined as the No. 3 function "three-wire operation control". 1111 1111 1116 +[[image:1681698530367-261.png||height="298" width="628"]] 1117 + 1112 1112 3: Three-line mode 2: The enable terminal of this mode is Din, the running command is given by FWD, and the direction is determined by the state of REV. The stop command is completed by disconnecting the Din signal. 1113 1113 1114 1114 Din is the multi-function input terminal of DI1~~DI6. At this time, the corresponding terminal function should be defined as the No. 3 function "three-wire operation control". 1115 1115 1122 +[[image:1681698557086-403.png||height="267" width="625"]] 1123 + 1124 + 1116 1116 (% class="table-bordered" %) 1117 1117 |(% rowspan="2" %)**F5.17**|UP/DOWN change rate range|Default|0.50Hz 1118 1118 |Setting range|(% colspan="2" %)0.01Hz~~65.535Hz
- 1681697850903-377.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.5 KB - Content
- 1681697969422-504.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.9 KB - Content
- 1681698530367-261.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.0 KB - Content
- 1681698557086-403.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.8 KB - Content