... ... @@ -1,1 +1,1 @@
1 -8 Function parameter details
1 +2.7 Function parameter details
Parent
... ... @@ -1,1 +1,1 @@
1 -VFD.VB AC Drive User Manual.WebHome
1 +2\. User Manual.WECON VB AC Drive User Manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Jim
1 +XWiki.admin
Content
... ... @@ -1,4 +1,4 @@
1 -= 1 F0 group basic parameters =
1 += 6.1 F0 group basic parameters =
2 2  
3 3  (% class="table-bordered" %)
4 4  |(% rowspan="3" %)**F0.00**|(% colspan="2" %)Motor control mode|Default|0
... ... @@ -51,7 +51,7 @@
51 51  |2|(% colspan="2" %)AI1
52 52  |3|(% colspan="2" %)AI2
53 53  |4|(% colspan="2" %)Reserved
54 -|5|(% colspan="2" %)PULSE setting(Reserved
54 +|5|(% colspan="2" %)Reserved
55 55  |6|(% colspan="2" %)Multi-stage speed setting
56 56  |7|(% colspan="2" %)Simple PLC
57 57  |8|(% colspan="2" %)PID
... ... @@ -59,13 +59,13 @@
59 59  
60 60  Select the main source of the AC drive’s input frequency. There are 10 main frequency sources:
61 61  
62 -**0:** Digital setting (non-retentive at power failure)
62 +0: Digital setting (non-retentive at power failure)
63 63  
64 64  The initial value is 0. The frequency can be increased or decreased by the pulse knob, and the set frequency value of the inverter can be changed by the ▲/▼ keys of the keyboard (or UP and DOWN of the multi-function input terminals).
65 65  
66 66  Non-retentive means that after the AC drive is powered off, the set frequency value will be restored to 0; it will be cleared after switching as the frequency source, so this parameter should not be the object of frequency source switching.
67 67  
68 -**1: **Digital setting (retentive at power failure)
68 +1: Digital setting (retentive at power failure)
69 69  
70 70  The initial value is the value of F0.08 "Keypad setting frequency".
71 71  
... ... @@ -73,33 +73,27 @@
73 73  
74 74  Retentive means that when the AC drive is powered on again after power failure, the set frequency is the value before the last power failure (note that it is used in conjunction with F0.23).
75 75  
76 -**2: **AI1
76 +2: AI1
77 77  
78 -**3:** AI2
78 +3: AI2
79 79  
80 80  Means that the frequency is determined by the analog input terminal. The standard unit provides 2 analog input terminals (AI1, AI2), among which AI1 is 0V~~10V voltage input, AI2 can be 0V~~10V voltage input, or 4mA~~20mA current input, Selected by jumper J8 on the control board.
81 81  
82 -**5: **PULSE setting(Reserved
82 +4/5: Reserved
83 83  
84 -The set frequency is given by the terminal pulse.
84 +6: Multi-stage speed
85 85  
86 -Pulse given signal specifications: voltage range 9V~~30V, frequency range 0kHz~~100kHz.
87 -
88 -Note: Pulse reference can only be input from the multi-function input terminal, __**requires custom control board development.**__
89 -
90 -**6: **Multi-stage speed
91 -
92 92  Select multi-stage speed operation mode. Need to set the F5 group "input terminals" and FD group "multi-stage speed and PLC" parameters to determine the corresponding relationship between the given signal and the given frequency.
93 93  
94 -**7: **Simple PLC
88 +7: Simple PLC
95 95  
96 96  Select simple PLC mode. When the frequency source is simple PLC, you need to set the FD group "multi-speed and PLC" parameters to determine the set frequency.
97 97  
98 -**8: **PID
92 +8: PID
99 99  
100 100  Select process PID control. At this time, you need to set the F9 group "PID function of process control ". The running frequency of the inverter is the frequency value after PID action. For the meaning of PID given source, given amount, feedback source, etc., please refer to the introduction of "PID Function of process control" in F9 group.
101 101  
102 -**9: **Communication setting
96 +9: Communication setting
103 103  
104 104  Means that the main frequency source is given by the upper machine through communication.
105 105  
... ... @@ -387,7 +387,7 @@
387 387  
388 388  The decimal place of the control frequency related instruction, the default is 2 decimal places. After the parameter is set, the decimal place of the parameter associated with the frequency is automatically adjusted. This parameter is not affected by F0.20.
389 389  
390 -= 2 F1 group start & stop control =
384 += 6.2 F1 group start & stop control =
391 391  
392 392  (% class="table-bordered" %)
393 393  |(% rowspan="4" %)**F1.00**|(% colspan="2" %)Starting mode|Default|0
... ... @@ -547,7 +547,7 @@
547 547  
548 548  Setting whether the AC drive has output when running frequency is 0
549 549  
550 -= 3 F2 group motor parameters =
544 += 6.3 F2 group motor parameters =
551 551  
552 552  (% class="table-bordered" %)
553 553  |(% rowspan="5" %)**F2.00**|(% colspan="2" %)Motor type selection|Default|0
... ... @@ -660,7 +660,7 @@
660 660  
661 661  The main and auxiliary winding currents can be changed by adjusting the single-phase motor turns ratio. Generally, reducing the single-phase motor turns ratio can increase the main winding current, reduce the auxiliary winding current, and reduce the motor heating (only effective when F2.00 = 3) .
662 662  
663 -= 4 F3 group vector control parameters =
657 += 6.4 F3 group vector control parameters =
664 664  
665 665  F3 group function codes are only valid in vector control mode, that is, it is valid when F0.00=0, and it is invalid when F0.00=1.
666 666  
... ... @@ -797,7 +797,7 @@
797 797  
798 798  During startup, torque command 1 = F3.11 * F3.24 / 100; after maintaining time F3.25 seconds, it will be restored to torque command 2 = F3.11; torque command 1/2 switching requires torque acceleration and deceleration time F3.14/F3.15.
799 799  
800 -= 5 F4 group v/f control parameters =
794 += 6.5 F4 group v/f control parameters =
801 801  
802 802  This group of function codes is only valid for V/F control (F0.00=1), and invalid for vector control.
803 803  
... ... @@ -966,7 +966,7 @@
966 966  
967 967  According to the actual use, select the situation where the AVR function is enabled.
968 968  
969 -= 6 F5 group input terminals =
963 += 6.6 F5 group input terminals =
970 970  
971 971  The standard unit of the VB series inverter has 6 multi-function digital input terminals and 2 analog input terminals.
972 972  
... ... @@ -1101,7 +1101,7 @@
1101 1101  
1102 1102  0: Two-line mode 1: This mode is the most commonly used two-line mode. The FWD and REV terminal commands determine the forward and reverse of the motor.
1103 1103  
1104 -1: Two-wire mode 2: FWD is the enable terminal when using this mode. The direction is determined by the state of the REV.
1098 +1: Two-wire mode 2: REV is the enable terminal when using this mode. The direction is determined by the state of the FWD.
1105 1105  
1106 1106  2: Three-line mode 1: This mode Din is the enable terminal, and the direction is controlled by FWD and REV respectively.
1107 1107  
... ... @@ -1157,6 +1157,20 @@
1157 1157  The function of AI2 is similar to the setting method of AI1.
1158 1158  
1159 1159  (% class="table-bordered" %)
1154 +|(% rowspan="2" %)**F5.28**|PULSE INPUT minimum input|Default|0.00kHz
1155 +|Setting range|(% colspan="2" %)0.00kHz~~F5.30 
1156 +|(% rowspan="2" %)**F5.29**|Percentage rate of PULSE INPUT minimum input|Default|0.0%
1157 +|Setting range|(% colspan="2" %)-100.00%~~100.0%
1158 +|(% rowspan="2" %)**F5.30**|PULSE INPUT maximum input|Default|50.00kHz
1159 +|Setting range|(% colspan="2" %)F5.28~~50.00kHz  
1160 +|(% rowspan="2" %)**F5.31**|Percentage rate of PULSE INPUT maximum input|Default|100.0%
1161 +|Setting range|(% colspan="2" %)-100.00%~~100.0%
1162 +|(% rowspan="2" %)**F5.32**|PULSE INPUT filter time|Default|0.10s
1163 +|Setting range|(% colspan="2" %)0.00s~~10.00s
1164 +
1165 +This group of function codes defines the corresponding relationship when pulse is used as the frequency setting method. Pulse frequency input can only be input through DI6 channel. The application of this group of functions is similar to that of AI1.
1166 +
1167 +(% class="table-bordered" %)
1160 1160  |(% rowspan="2" %)**F5.33**|DI1 enable delay time|Default|0.0s
1161 1161  |Setting range|(% colspan="2" %)0.0s~~3600.0s
1162 1162  |(% rowspan="2" %)**F5.34**|DI1 disable delay time|Default|0.0s
... ... @@ -1194,7 +1194,7 @@
1194 1194  
1195 1195  Low Level:The connection between DI terminal and COM is invalid, while disconnection is valid.
1196 1196  
1197 -= 7 F6 group output terminals =
1205 += 6.7 F6 group output terminals =
1198 1198  
1199 1199  The standard unit of VB series inverter has 2 multi-function relay output terminals, 1 FM terminal and 2 multi-function analog output terminals.
1200 1200  
... ... @@ -1448,14 +1448,8 @@
1448 1448  
1449 1449  For the second output, the parameter setting method is the same as F6.28~~F6.32.
1450 1450  
1451 -(% class="table-bordered" %)
1452 -|(% rowspan="2" %)**F6.38**|The setting time of timer|Default|0
1453 -|Setting range|(% colspan="3" %)0.00s~~100.0s
1459 += 6.8 F7 group keypad display =
1454 1454  
1455 -Set the timer setting time
1456 -
1457 -= 8 F7 group keypad display =
1458 -
1459 1459  (% class="table-bordered" %)
1460 1460  |(% rowspan="4" %)**F7.00**|(% colspan="2" %)LCD keypad parameter copy|Default|0
1461 1461  |(% rowspan="3" %)Setting range|0|(% colspan="2" %)No operation
... ... @@ -1665,7 +1665,7 @@
1665 1665  |(% rowspan="2" %)**F7.15**|Performance software version|Default|-
1666 1666  |Setting range|(% colspan="2" %)-
1667 1667  
1668 -= 9 F8 group auxiliary functions =
1670 += 6.9 F8 group auxiliary functions =
1669 1669  
1670 1670  (% class="table-bordered" %)
1671 1671  |(% rowspan="2" %)**F8.00**|JOG running frequency|Default|2.00Hz
... ... @@ -1965,7 +1965,7 @@
1965 1965  
1966 1966  Enabling the fast current limiting function can minimize the inverter's overcurrent fault and protect the inverter from uninterrupted operation. After entering the fast current-limiting state for a period of time, a fast current-limiting fault (Err40) will be reported, indicating that the inverter is overloaded. Please refer to the handling of Err10.
1967 1967  
1968 -= 10 F9 group pid function of process control =
1970 += 6.10 F9 group pid function of process control =
1969 1969  
1970 1970  PID control is a common method used in process control. It adjusts the output frequency of the inverter by performing proportional, integral, and differential calculations on the difference between the feedback signal of the controlled quantity and the target quantity signal to form a negative feedback system. The controlled amount is stable at the target amount. It is suitable for process control such as flow control, pressure control and temperature control. The basic control block diagram is as follows:
1971 1971  
... ... @@ -2167,8 +2167,9 @@
2167 2167  
2168 2168  Figure 6-10-2 PID sleep and wake-up timing diagram
2169 2169  
2170 -= 11 FA group faults & protection =
2171 2171  
2173 += 6.11 FA group faults & protection =
2174 +
2172 2172  (% class="table-bordered" %)
2173 2173  |(% rowspan="3" %)**FA.00**|Motor overload protection selection|Default|1
2174 2174  |(% rowspan="2" %)Setting range|0|Disabled
... ... @@ -2401,7 +2401,7 @@
2401 2401  
2402 2402  Note: The function code display data is H.xxx, where H. means hexadecimal data.
2403 2403  
2404 -= 12 FB group frequency swing, length fixing and counting =
2407 += 6.12 FB group frequency swing, length fixing and counting =
2405 2405  
2406 2406  The swing frequency function is suitable for textile, chemical fiber and other industries and occasions that require traverse and winding functions.
2407 2407  
... ... @@ -2488,7 +2488,7 @@
2488 2488  
2489 2489  Figure 6-12-2 Schematic diagram of set count value given and designated count value given
2490 2490  
2491 -= 13 FC group communication parameters =
2494 += 6.13 FC group communication parameters =
2492 2492  
2493 2493  (% class="table-bordered" %)
2494 2494  |(% rowspan="2" %)**FC.00**|Local address|Default|1
... ... @@ -2539,7 +2539,7 @@
2539 2539  
2540 2540  Used to determine the output unit of the current value when the communication reads the output current.
2541 2541  
2542 -= 14 FD group muti-stage speed and simple plc functions =
2545 += 6.14 FD group muti-stage speed and simple plc functions =
2543 2543  
2544 2544  The simple PLC function is that the inverter has a programmable controller (PLC) built in to complete automatic control of multi-segment frequency logic. The running time, running direction and running frequency can be set to meet the technological requirements. This series of inverters can realize 16-speed change control, and there are 4 kinds of acceleration and deceleration time for selection. When the set PLC completes a cycle, an ON signal can be output from the multifunctional digital output terminals DO1 and DO2 or multifunctional relay 1 and relay 2. See F1.02~~F1.05 for details. When the frequency source selection F0.07, F0.03, F0.04 is determined as the multi-speed operation mode, it is necessary to set FD.00~~FD.15 to determine its characteristics.
2545 2545  
... ... @@ -2698,7 +2698,7 @@
2698 2698  
2699 2699  This parameter determines the target quantity given channel of multi-speed 0.
2700 2700  
2701 -= 15 FE group user password management =
2704 += 6.15 FE group user password management =
2702 2702  
2703 2703  (% class="table-bordered" %)
2704 2704  |(% rowspan="2" %)**FE.00**|User password|Default|0