Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 8.1
edited by Jim(Forgotten)
on 2023/04/13 10:17
on 2023/04/13 10:17
Change comment:
There is no comment for this version
To version 10.1
edited by Theodore Xu
on 2023/07/11 16:30
on 2023/07/11 16:30
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.AiXia - Content
-
... ... @@ -260,6 +260,8 @@ 260 260 |(% rowspan="2" %)** F0.16**|Carrier Frequency|Default|Model Dependent 261 261 |Setting Range|(% colspan="2" %)0.5kHz~~16.0kHz 262 262 263 += Carrier Frequency: = 264 + 263 263 This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced. 264 264 265 265 When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases. ... ... @@ -1101,18 +1101,27 @@ 1101 1101 1102 1102 0: Two-line mode 1: This mode is the most commonly used two-line mode. The FWD and REV terminal commands determine the forward and reverse of the motor. 1103 1103 1106 +[[image:1681697850903-377.png||height="282" width="633"]] 1107 + 1104 1104 1: Two-wire mode 2: FWD is the enable terminal when using this mode. The direction is determined by the state of the REV. 1105 1105 1106 - 2: Three-linemode 1: This mode Din is the enableterminal, and the direction is controlled by FWD and REV respectively.1110 +[[image:1681697969422-504.png]] 1107 1107 1108 - Butthepulse isvalid,it mustbecompletedbydisconnectingtheDin terminalsignalwhen stopping.1112 +2: Three-line mode 1: This mode Din(function code 3) is the enable terminal, and the direction is controlled by FWD and REV respectively. 1109 1109 1114 +DIN is pulse effective, user need to disconnect the Din terminal signal when stop. 1115 + 1110 1110 Din is the multifunctional input terminal of DI1~~DI6. At this time, the corresponding terminal function should be defined as the No. 3 function "three-wire operation control". 1111 1111 1118 +[[image:1681698530367-261.png||height="298" width="628"]] 1119 + 1112 1112 3: Three-line mode 2: The enable terminal of this mode is Din, the running command is given by FWD, and the direction is determined by the state of REV. The stop command is completed by disconnecting the Din signal. 1113 1113 1114 1114 Din is the multi-function input terminal of DI1~~DI6. At this time, the corresponding terminal function should be defined as the No. 3 function "three-wire operation control". 1115 1115 1124 +[[image:1681698557086-403.png||height="267" width="625"]] 1125 + 1126 + 1116 1116 (% class="table-bordered" %) 1117 1117 |(% rowspan="2" %)**F5.17**|UP/DOWN change rate range|Default|0.50Hz 1118 1118 |Setting range|(% colspan="2" %)0.01Hz~~65.535Hz
- 1681697850903-377.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.5 KB - Content
- 1681697969422-504.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.9 KB - Content
- 1681698530367-261.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.0 KB - Content
- 1681698557086-403.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.8 KB - Content