Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 8.1
edited by Jim(Forgotten)
on 2023/04/13 10:17
on 2023/04/13 10:17
Change comment:
There is no comment for this version
To version 14.1
edited by Theodore Xu
on 2023/08/23 15:47
on 2023/08/23 15:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.AiXia - Content
-
... ... @@ -260,6 +260,8 @@ 260 260 |(% rowspan="2" %)** F0.16**|Carrier Frequency|Default|Model Dependent 261 261 |Setting Range|(% colspan="2" %)0.5kHz~~16.0kHz 262 262 263 += Carrier Frequency: = 264 + 263 263 This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced. 264 264 265 265 When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases. ... ... @@ -1101,18 +1101,27 @@ 1101 1101 1102 1102 0: Two-line mode 1: This mode is the most commonly used two-line mode. The FWD and REV terminal commands determine the forward and reverse of the motor. 1103 1103 1106 +[[image:1681697850903-377.png||height="282" width="633"]] 1107 + 1104 1104 1: Two-wire mode 2: FWD is the enable terminal when using this mode. The direction is determined by the state of the REV. 1105 1105 1106 - 2: Three-linemode 1: This mode Din is the enableterminal, and the direction is controlled by FWD and REV respectively.1110 +[[image:1681697969422-504.png]] 1107 1107 1108 - Butthepulse isvalid,it mustbecompletedbydisconnectingtheDin terminalsignalwhen stopping.1112 +2: Three-line mode 1: This mode Din(function code 3) is the enable terminal, and the direction is controlled by FWD and REV respectively. 1109 1109 1114 +DIN is pulse effective, user need to disconnect the Din terminal signal when stop. 1115 + 1110 1110 Din is the multifunctional input terminal of DI1~~DI6. At this time, the corresponding terminal function should be defined as the No. 3 function "three-wire operation control". 1111 1111 1118 +[[image:1681698530367-261.png||height="298" width="628"]] 1119 + 1112 1112 3: Three-line mode 2: The enable terminal of this mode is Din, the running command is given by FWD, and the direction is determined by the state of REV. The stop command is completed by disconnecting the Din signal. 1113 1113 1114 1114 Din is the multi-function input terminal of DI1~~DI6. At this time, the corresponding terminal function should be defined as the No. 3 function "three-wire operation control". 1115 1115 1124 +[[image:1681698557086-403.png||height="267" width="625"]] 1125 + 1126 + 1116 1116 (% class="table-bordered" %) 1117 1117 |(% rowspan="2" %)**F5.17**|UP/DOWN change rate range|Default|0.50Hz 1118 1118 |Setting range|(% colspan="2" %)0.01Hz~~65.535Hz ... ... @@ -2291,23 +2291,17 @@ 2291 2291 |(% rowspan="9" %)**FA.15**|(% colspan="2" style="width:442px" %)Fault protection action selection 3|(% style="width:451px" %)Default|(% colspan="2" %)00000 2292 2292 |(% rowspan="7" %)Setting range|(% style="width:316px" %)Ones Place|(% colspan="3" style="width:978px" %)User-defined fault 1(Err27) (0~~2,as ones place of FA.13) 2293 2293 |(% style="width:316px" %)Tens Place|(% colspan="3" style="width:978px" %)User-defined fault 2(Err28) (0~~2,as ones place of FA.13) 2294 -|(% style="width:316px" %)Hundr -eds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)2295 -|(% style="width:316px" %)Thous -ands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)2305 +|(% style="width:316px" %)Hundreds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13) 2306 +|(% style="width:316px" %)Thousands Place|(% colspan="3" style="width:978px" %)Load loss(Err30) 2296 2296 |(% style="width:316px" %)0|(% colspan="3" style="width:978px" %)Free stopping 2297 2297 |(% style="width:316px" %)1|(% colspan="3" style="width:978px" %)Stop according to the stop mode 2298 2298 |(% style="width:316px" %)2|(% colspan="3" style="width:978px" %)Decelerate to 7% of the rated frequency of the motor and continue to run, and automatically return to the set frequency if the load is not lost 2299 -| |(% style="width:316px" %)Ten thous -ands Place|(% colspan="3" style="width:978px" %)(((2310 +| |(% style="width:316px" %)Ten thousands Place|(% colspan="3" style="width:978px" %)((( 2300 2300 PID feedback loss during 2301 2301 2302 2302 Running (Err31) (0~~2,as ones place of FA.13) 2303 2303 ))) 2304 -|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)((( 2305 -Overcurrent stall Integral coefficient 2306 -)))|(% colspan="2" style="width:451px" %)Default|500 2307 -|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000 2308 2308 2309 -set overcurrent stall Integral coefficient rate. 2310 - 2311 2311 When “free stop” is selected: the inverter prompts Err~*~* and stops directly. 2312 2312 2313 2313 When "Stop according to stop mode" is selected: the inverter prompts A~*~* and stops according to the stop mode, and prompts ErrXX after stopping. ... ... @@ -2315,22 +2315,29 @@ 2315 2315 When “continue running” is selected: the inverter continues to run and prompts A~*~*. For the running frequency, refer to the description of FA.20 and FA.21. 2316 2316 2317 2317 (% class="table-bordered" %) 2318 -|(% rowspan="2" %)((( 2319 -FA.17 2320 -)))|((( 2321 -Undervoltage setting 2322 -)))|((( 2323 +|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)((( 2324 +Overcurrent stall Integral coefficient 2325 +)))|(% colspan="2" style="width:451px" %)Default|500 2326 +|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000 2327 + 2328 +Set overcurrent stall Integral coefficient rate. 2329 + 2330 +(% class="table-bordered" %) 2331 +|(% rowspan="3" %)((( 2332 +**FA.17** 2333 +)))|(% colspan="2" rowspan="1" %)Instant stop /no-stop mode |((( 2323 2323 Default 2324 2324 )))|((( 2325 - 100.0%2336 +0 2326 2326 ))) 2327 -|((( 2338 +|(% colspan="1" rowspan="2" %)((( 2328 2328 Setting range 2329 -)))|(% colspan="2" rowspan="1" %)((( 2330 - 60.0%~~140.0%2340 +)))|(% rowspan="1" %)0|(% colspan="2" rowspan="1" %)((( 2341 +General machine instant stop/no-stop 2331 2331 ))) 2343 +|1|(% colspan="2" %)Spinning machine instant stop/no-stop 2332 2332 2333 - Instantaneouspowerfailuremodeselection2345 +Set the mode of instant stop and no-stop. 2334 2334 2335 2335 (% class="table-bordered" %) 2336 2336 |(% rowspan="2" %)**FA.18**|Undervoltage setting|Default|100.0%
- 1681697850903-377.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.5 KB - Content
- 1681697969422-504.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.9 KB - Content
- 1681698530367-261.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.0 KB - Content
- 1681698557086-403.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.8 KB - Content