... ... @@ -51,7 +51,7 @@
51 51  |2|(% colspan="2" %)AI1
52 52  |3|(% colspan="2" %)AI2
53 53  |4|(% colspan="2" %)Reserved
54 -|5|(% colspan="2" %)PULSE setting(Reserved
54 +|5|(% colspan="2" %)Reserved
55 55  |6|(% colspan="2" %)Multi-stage speed setting
56 56  |7|(% colspan="2" %)Simple PLC
57 57  |8|(% colspan="2" %)PID
... ... @@ -79,7 +79,7 @@
79 79  
80 80  Means that the frequency is determined by the analog input terminal. The standard unit provides 2 analog input terminals (AI1, AI2), among which AI1 is 0V~~10V voltage input, AI2 can be 0V~~10V voltage input, or 4mA~~20mA current input, Selected by jumper J8 on the control board.
81 81  
82 -**5: **PULSE setting(Reserved)
82 +**4/5: **PULSE setting(Reserved)
83 83  
84 84  The set frequency is given by the terminal pulse.
85 85  
... ... @@ -1157,6 +1157,20 @@
1157 1157  The function of AI2 is similar to the setting method of AI1.
1158 1158  
1159 1159  (% class="table-bordered" %)
1160 +|(% rowspan="2" %)**F5.28**|PULSE INPUT minimum input|Default|0.00kHz
1161 +|Setting range|(% colspan="2" %)0.00kHz~~F5.30 
1162 +|(% rowspan="2" %)**F5.29**|Percentage rate of PULSE INPUT minimum input|Default|0.0%
1163 +|Setting range|(% colspan="2" %)-100.00%~~100.0%
1164 +|(% rowspan="2" %)**F5.30**|PULSE INPUT maximum input|Default|50.00kHz
1165 +|Setting range|(% colspan="2" %)F5.28~~50.00kHz  
1166 +|(% rowspan="2" %)**F5.31**|Percentage rate of PULSE INPUT maximum input|Default|100.0%
1167 +|Setting range|(% colspan="2" %)-100.00%~~100.0%
1168 +|(% rowspan="2" %)**F5.32**|PULSE INPUT filter time|Default|0.10s
1169 +|Setting range|(% colspan="2" %)0.00s~~10.00s
1170 +
1171 +This group of function codes defines the corresponding relationship when pulse is used as the frequency setting method. Pulse frequency input can only be input through DI6 channel. The application of this group of functions is similar to that of AI1.
1172 +
1173 +(% class="table-bordered" %)
1160 1160  |(% rowspan="2" %)**F5.33**|DI1 enable delay time|Default|0.0s
1161 1161  |Setting range|(% colspan="2" %)0.0s~~3600.0s
1162 1162  |(% rowspan="2" %)**F5.34**|DI1 disable delay time|Default|0.0s
... ... @@ -1448,12 +1448,6 @@
1448 1448  
1449 1449  For the second output, the parameter setting method is the same as F6.28~~F6.32.
1450 1450  
1451 -(% class="table-bordered" %)
1452 -|(% rowspan="2" %)**F6.38**|The setting time of timer|Default|0
1453 -|Setting range|(% colspan="3" %)0.00s~~100.0s
1454 -
1455 -Set the timer setting time
1456 -