Changes for page 08 Function parameter details
Last modified by Theodore Xu on 2025/02/21 14:13
From version 8.1
edited by Jim(Forgotten)
on 2023/04/13 10:17
on 2023/04/13 10:17
Change comment:
There is no comment for this version
To version 5.1
edited by Jim(Forgotten)
on 2023/04/13 09:47
on 2023/04/13 09:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -51,7 +51,7 @@ 51 51 |2|(% colspan="2" %)AI1 52 52 |3|(% colspan="2" %)AI2 53 53 |4|(% colspan="2" %)Reserved 54 -|5|(% colspan="2" %) PULSE setting(Reserved)54 +|5|(% colspan="2" %)Reserved 55 55 |6|(% colspan="2" %)Multi-stage speed setting 56 56 |7|(% colspan="2" %)Simple PLC 57 57 |8|(% colspan="2" %)PID ... ... @@ -79,7 +79,7 @@ 79 79 80 80 Means that the frequency is determined by the analog input terminal. The standard unit provides 2 analog input terminals (AI1, AI2), among which AI1 is 0V~~10V voltage input, AI2 can be 0V~~10V voltage input, or 4mA~~20mA current input, Selected by jumper J8 on the control board. 81 81 82 -**5: **PULSE setting(Reserved) 82 +**4/5: **PULSE setting(Reserved) 83 83 84 84 The set frequency is given by the terminal pulse. 85 85 ... ... @@ -1157,6 +1157,20 @@ 1157 1157 The function of AI2 is similar to the setting method of AI1. 1158 1158 1159 1159 (% class="table-bordered" %) 1160 +|(% rowspan="2" %)**F5.28**|PULSE INPUT minimum input|Default|0.00kHz 1161 +|Setting range|(% colspan="2" %)0.00kHz~~F5.30 1162 +|(% rowspan="2" %)**F5.29**|Percentage rate of PULSE INPUT minimum input|Default|0.0% 1163 +|Setting range|(% colspan="2" %)-100.00%~~100.0% 1164 +|(% rowspan="2" %)**F5.30**|PULSE INPUT maximum input|Default|50.00kHz 1165 +|Setting range|(% colspan="2" %)F5.28~~50.00kHz 1166 +|(% rowspan="2" %)**F5.31**|Percentage rate of PULSE INPUT maximum input|Default|100.0% 1167 +|Setting range|(% colspan="2" %)-100.00%~~100.0% 1168 +|(% rowspan="2" %)**F5.32**|PULSE INPUT filter time|Default|0.10s 1169 +|Setting range|(% colspan="2" %)0.00s~~10.00s 1170 + 1171 +This group of function codes defines the corresponding relationship when pulse is used as the frequency setting method. Pulse frequency input can only be input through DI6 channel. The application of this group of functions is similar to that of AI1. 1172 + 1173 +(% class="table-bordered" %) 1160 1160 |(% rowspan="2" %)**F5.33**|DI1 enable delay time|Default|0.0s 1161 1161 |Setting range|(% colspan="2" %)0.0s~~3600.0s 1162 1162 |(% rowspan="2" %)**F5.34**|DI1 disable delay time|Default|0.0s ... ... @@ -1448,12 +1448,6 @@ 1448 1448 1449 1449 For the second output, the parameter setting method is the same as F6.28~~F6.32. 1450 1450 1451 -(% class="table-bordered" %) 1452 -|(% rowspan="2" %)**F6.38**|The setting time of timer|Default|0 1453 -|Setting range|(% colspan="3" %)0.00s~~100.0s 1454 - 1455 -Set the timer setting time 1456 - 1457 1457 = 8 F7 group keypad display = 1458 1458 1459 1459 (% class="table-bordered" %)