... ... @@ -260,6 +260,8 @@
260 260  |(% rowspan="2" %)** F0.16**|Carrier Frequency|Default|Model Dependent
261 261  |Setting Range|(% colspan="2" %)0.5kHz~~16.0kHz
262 262  
263 += Carrier Frequency: =
264 +
263 263  This function adjusts the carrier frequency of the AC drive. By adjusting the carrier frequency, the motor noise can be reduced, the resonance point of the mechanical system can be avoided, the leakage current of the line to the ground and the interference caused by the inverter can be reduced.
264 264  
265 265  When the carrier frequency is low, the higher harmonic components of the output current increase, the motor loss increases, and the motor temperature rise increases.
... ... @@ -2300,23 +2300,17 @@
2300 2300  |(% rowspan="9" %)**FA.15**|(% colspan="2" style="width:442px" %)Fault protection action selection 3|(% style="width:451px" %)Default|(% colspan="2" %)00000
2301 2301  |(% rowspan="7" %)Setting range|(% style="width:316px" %)Ones Place|(% colspan="3" style="width:978px" %)User-defined fault 1(Err27) (0~~2,as ones place of FA.13)
2302 2302  |(% style="width:316px" %)Tens Place|(% colspan="3" style="width:978px" %)User-defined fault 2(Err28) (0~~2,as ones place of FA.13)
2303 -|(% style="width:316px" %)Hundr-eds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)
2304 -|(% style="width:316px" %)Thous-ands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)
2305 +|(% style="width:316px" %)Hundreds Place|(% colspan="3" style="width:978px" %)Powering on time reached(Err29) (0~~2,as ones place of FA.13)
2306 +|(% style="width:316px" %)Thousands Place|(% colspan="3" style="width:978px" %)Load loss(Err30)
2305 2305  |(% style="width:316px" %)0|(% colspan="3" style="width:978px" %)Free stopping
2306 2306  |(% style="width:316px" %)1|(% colspan="3" style="width:978px" %)Stop according to the stop mode
2307 2307  |(% style="width:316px" %)2|(% colspan="3" style="width:978px" %)Decelerate to 7% of the rated frequency of the motor and continue to run, and automatically return to the set frequency if the load is not lost
2308 -| |(% style="width:316px" %)Ten thous-ands Place|(% colspan="3" style="width:978px" %)(((
2310 +| |(% style="width:316px" %)Ten thousands Place|(% colspan="3" style="width:978px" %)(((
2309 2309  PID feedback loss during
2310 2310  
2311 2311  Running (Err31) (0~~2,as ones place of FA.13)
2312 2312  )))
2313 -|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)(((
2314 -Overcurrent stall Integral coefficient
2315 -)))|(% colspan="2" style="width:451px" %)Default|500
2316 -|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000
2317 2317  
2318 -set overcurrent stall Integral coefficient rate.
2319 -
2320 2320  When “free stop” is selected: the inverter prompts Err~*~* and stops directly.
2321 2321  
2322 2322  When "Stop according to stop mode" is selected: the inverter prompts A~*~* and stops according to the stop mode, and prompts ErrXX after stopping.
... ... @@ -2324,22 +2324,29 @@
2324 2324  When “continue running” is selected: the inverter continues to run and prompts A~*~*. For the running frequency, refer to the description of FA.20 and FA.21.
2325 2325  
2326 2326  (% class="table-bordered" %)
2327 -|(% rowspan="2" %)(((
2328 -FA.17
2329 -)))|(((
2330 -Undervoltage setting
2331 -)))|(((
2323 +|(% rowspan="6" %)**FA.16**|(% colspan="2" style="width:442px" %)(((
2324 +Overcurrent stall Integral coefficient
2325 +)))|(% colspan="2" style="width:451px" %)Default|500
2326 +|(% rowspan="5" %)Setting range|(% colspan="4" rowspan="5" %)1~~2000
2327 +
2328 +Set overcurrent stall Integral coefficient rate.
2329 +
2330 +(% class="table-bordered" %)
2331 +|(% rowspan="3" %)(((
2332 +**FA.17**
2333 +)))|(% colspan="2" rowspan="1" %)Instant stop /no-stop mode |(((
2332 2332  Default
2333 2333  )))|(((
2334 -100.0%
2336 +0
2335 2335  )))
2336 -|(((
2338 +|(% colspan="1" rowspan="2" %)(((
2337 2337  Setting range
2338 -)))|(% colspan="2" rowspan="1" %)(((
2339 -60.0%~~140.0%
2340 +)))|(% rowspan="1" %)0|(% colspan="2" rowspan="1" %)(((
2341 +General machine instant stop/no-stop
2340 2340  )))
2343 +|1|(% colspan="2" %)Spinning machine instant stop/no-stop
2341 2341  
2342 -Instantaneous power failure mode selection
2345 +Set the mode of instant stop and no-stop.
2343 2343  
2344 2344  (% class="table-bordered" %)
2345 2345  |(% rowspan="2" %)**FA.18**|Undervoltage setting|Default|100.0%