Changes for page 09 Appendix A Selection Guide
Last modified by Theodore Xu on 2025/04/12 09:37
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 09 Appendix a selection guide1 +9 Appendix a selection guide - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Jim - Content
-
... ... @@ -1,10 +1,5 @@ 1 -= Braking resistor selection = 1 += 1 Braking resistor selection = 2 2 3 -(% class="box infomessage" %) 4 -((( 5 -**✎Note:** Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors. 6 -))) 7 - 8 8 (% class="table-bordered" %) 9 9 |(% rowspan="2" %)**AC Drive Model**|(% style="width:227px" %)**Inverter Power**|(% style="width:250px" %)((( 10 10 **Braking resistor power** ... ... @@ -44,8 +44,11 @@ 44 44 |VB-4T315G/355P|(% style="width:227px" %)315/355|(% style="width:250px" %)31.5/79.0|(% style="width:329px" %)2.0 45 45 |VB-4T355G/400P|(% style="width:227px" %)355/400|(% style="width:250px" %)35.5/89.0|(% style="width:329px" %)1.5 46 46 |VB-4T400G|(% style="width:227px" %)400.0|(% style="width:250px" %)40.0/100.0|(% style="width:329px" %)1.5 42 +|(% colspan="4" %)((( 43 +**✎Note: **t(% style="background-color:transparent" %)he braking resistor power is configured for general occasions, and the unwinding application should be 2~~3 times the power of general conditions, and the maximum power can be up to 6 times in the case of frequent braking. 44 +))) 47 47 48 -= Recommended power terminal wire = 46 += 2 Recommended power terminal wire = 49 49 50 50 (% class="table-bordered" %) 51 51 |(% rowspan="2" style="width:190px" %)**AC Drive Model**|(% style="width:74px" %)**Power**|(% style="width:157px" %)**Rated input current**|(% style="width:188px" %)**Rated output current**|(% style="width:227px" %)**Recommended input cable**|(% style="width:305px" %)**Recommended output cable**|(% style="width:348px" %)**Main terminal adapter lug** ... ... @@ -83,7 +83,7 @@ 83 83 |(% style="width:190px" %)VB-4T355G/400P|(% style="width:74px" %)355/400|(% style="width:157px" %)665/785|(% style="width:188px" %)650/725|(% style="width:227px" %)2x185|(% style="width:305px" %)2x185|(% style="width:348px" %)GTNR 185-16 84 84 |(% style="width:190px" %)VB-4T400G|(% style="width:74px" %)400|(% style="width:157px" %)785|(% style="width:188px" %)725|(% style="width:227px" %)2x240|(% style="width:305px" %)2x240|(% style="width:348px" %)GTNR 240-16 85 85 86 -= Ground wire selectio = 84 += 3 Ground wire selectio = 87 87 88 88 ~1. The terminal must be grounded reliably, and the resistance of the grounding wire must be less than 0.1Ω. Otherwise, the equipment will work abnormally or even be damaged. 89 89