Changes for page 09 Appendix A Selection Guide
Last modified by Theodore Xu on 2025/04/12 09:37
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 09 AppendixAselection guide1 +9 Appendix a selection guide - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Jim - Content
-
... ... @@ -1,14 +1,7 @@ 1 -= Braking resistor selection = 1 += 1 Braking resistor selection = 2 2 3 -(% class="box infomessage" %) 4 -((( 5 -**✎Note** 3 +**✎Note:** Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors. 6 6 7 -When VFD install Braking resistor,it needs set F4.16=0,FA.03=0,FA.04=120. 8 - 9 -Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors. 10 -))) 11 - 12 12 (% class="table-bordered" %) 13 13 |(% rowspan="2" %)**AC Drive Model**|(% style="width:227px" %)**Inverter Power**|(% style="width:250px" %)((( 14 14 **Braking resistor power** ... ... @@ -49,7 +49,7 @@ 49 49 |VB-4T355G/400P|(% style="width:227px" %)355/400|(% style="width:250px" %)35.5/89.0|(% style="width:329px" %)1.5 50 50 |VB-4T400G|(% style="width:227px" %)400.0|(% style="width:250px" %)40.0/100.0|(% style="width:329px" %)1.5 51 51 52 -= Recommended power terminal wire = 45 += 2 Recommended power terminal wire = 53 53 54 54 (% class="table-bordered" %) 55 55 |(% rowspan="2" style="width:190px" %)**AC Drive Model**|(% style="width:74px" %)**Power**|(% style="width:157px" %)**Rated input current**|(% style="width:188px" %)**Rated output current**|(% style="width:227px" %)**Recommended input cable**|(% style="width:305px" %)**Recommended output cable**|(% style="width:348px" %)**Main terminal adapter lug** ... ... @@ -87,7 +87,7 @@ 87 87 |(% style="width:190px" %)VB-4T355G/400P|(% style="width:74px" %)355/400|(% style="width:157px" %)665/785|(% style="width:188px" %)650/725|(% style="width:227px" %)2x185|(% style="width:305px" %)2x185|(% style="width:348px" %)GTNR 185-16 88 88 |(% style="width:190px" %)VB-4T400G|(% style="width:74px" %)400|(% style="width:157px" %)785|(% style="width:188px" %)725|(% style="width:227px" %)2x240|(% style="width:305px" %)2x240|(% style="width:348px" %)GTNR 240-16 89 89 90 -= Ground wire selectio = 83 += 3 Ground wire selectio = 91 91 92 92 ~1. The terminal must be grounded reliably, and the resistance of the grounding wire must be less than 0.1Ω. Otherwise, the equipment will work abnormally or even be damaged. 93 93