... ... @@ -4,8 +4,10 @@
4 4  (((
5 5  **✎Note**
6 6  
7 -When VFD install Braking resistor,it needs set F4.16=0,FA.03=0,FA.04=120.
7 +0.75kW-22kW:VB default support barking unit so just install Braking resistor. Please set F4.16=0,FA.03=0,FA.04=120.
8 8  
9 +37kW and above:VB does not support the default barking unit, so need to install external brake unit and brake resistor. Please set F4.16=0, FA.03=0, FA.04=150.
10 +
9 9  Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors.
10 10  )))