Last modified by Theodore Xu on 2025/04/12 09:37

From version 14.1
edited by Mora Zhou
on 2024/11/19 09:43
Change comment: There is no comment for this version
To version 9.1
edited by Mora Zhou
on 2023/11/20 14:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -09 Appendix A Selection Guide
1 +09 Appendix a selection guide
Content
... ... @@ -1,12 +1,8 @@
1 -= Braking resistor selection =
1 += 1 Braking resistor selection =
2 2  
3 3  (% class="box infomessage" %)
4 4  (((
5 -**✎Note**
6 -
7 -When VFD install Braking resistor,it needs set F4.16=0,FA.03=0,FA.04=120.
8 -
9 -Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors.
5 +**✎Note:** Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors.
10 10  )))
11 11  
12 12  (% class="table-bordered" %)
... ... @@ -49,7 +49,7 @@
49 49  |VB-4T355G/400P|(% style="width:227px" %)355/400|(% style="width:250px" %)35.5/89.0|(% style="width:329px" %)1.5
50 50  |VB-4T400G|(% style="width:227px" %)400.0|(% style="width:250px" %)40.0/100.0|(% style="width:329px" %)1.5
51 51  
52 -= Recommended power terminal wire =
48 += 2 Recommended power terminal wire =
53 53  
54 54  (% class="table-bordered" %)
55 55  |(% rowspan="2" style="width:190px" %)**AC Drive Model**|(% style="width:74px" %)**Power**|(% style="width:157px" %)**Rated input current**|(% style="width:188px" %)**Rated output current**|(% style="width:227px" %)**Recommended input cable**|(% style="width:305px" %)**Recommended output cable**|(% style="width:348px" %)**Main terminal adapter lug**
... ... @@ -87,7 +87,7 @@
87 87  |(% style="width:190px" %)VB-4T355G/400P|(% style="width:74px" %)355/400|(% style="width:157px" %)665/785|(% style="width:188px" %)650/725|(% style="width:227px" %)2x185|(% style="width:305px" %)2x185|(% style="width:348px" %)GTNR 185-16
88 88  |(% style="width:190px" %)VB-4T400G|(% style="width:74px" %)400|(% style="width:157px" %)785|(% style="width:188px" %)725|(% style="width:227px" %)2x240|(% style="width:305px" %)2x240|(% style="width:348px" %)GTNR 240-16
89 89  
90 -= Ground wire selection =
86 += 3 Ground wire selectio =
91 91  
92 92  ~1. The terminal must be grounded reliably, and the resistance of the grounding wire must be less than 0.1Ω. Otherwise, the equipment will work abnormally or even be damaged.
93 93