Changes for page 09 Appendix A Selection Guide
Last modified by Theodore Xu on 2025/04/12 09:37
From version 15.1
edited by Theodore Xu
on 2025/03/04 16:11
on 2025/03/04 16:11
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 09 AppendixASelectionGuide1 +9 Appendix a selection guide - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Jim - Content
-
... ... @@ -1,16 +1,7 @@ 1 -= Braking resistor selection = 1 += 1 Braking resistor selection = 2 2 3 -(% class="box infomessage" %) 4 -((( 5 -**✎Note** 3 +**✎Note:** Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors. 6 6 7 -0.75kW-22kW:VB default support barking unit so just install Braking resistor. Please set F4.16=0,FA.03=0,FA.04=120. 8 - 9 -37kW and above:VB does not support the default barking unit, so need to install external brake unit and brake resistor. Please set F4.16=0, FA.03=0, FA.04=150. 10 - 11 -Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors. 12 -))) 13 - 14 14 (% class="table-bordered" %) 15 15 |(% rowspan="2" %)**AC Drive Model**|(% style="width:227px" %)**Inverter Power**|(% style="width:250px" %)((( 16 16 **Braking resistor power** ... ... @@ -51,7 +51,7 @@ 51 51 |VB-4T355G/400P|(% style="width:227px" %)355/400|(% style="width:250px" %)35.5/89.0|(% style="width:329px" %)1.5 52 52 |VB-4T400G|(% style="width:227px" %)400.0|(% style="width:250px" %)40.0/100.0|(% style="width:329px" %)1.5 53 53 54 -= Recommended power terminal wire = 45 += 2 Recommended power terminal wire = 55 55 56 56 (% class="table-bordered" %) 57 57 |(% rowspan="2" style="width:190px" %)**AC Drive Model**|(% style="width:74px" %)**Power**|(% style="width:157px" %)**Rated input current**|(% style="width:188px" %)**Rated output current**|(% style="width:227px" %)**Recommended input cable**|(% style="width:305px" %)**Recommended output cable**|(% style="width:348px" %)**Main terminal adapter lug** ... ... @@ -89,7 +89,7 @@ 89 89 |(% style="width:190px" %)VB-4T355G/400P|(% style="width:74px" %)355/400|(% style="width:157px" %)665/785|(% style="width:188px" %)650/725|(% style="width:227px" %)2x185|(% style="width:305px" %)2x185|(% style="width:348px" %)GTNR 185-16 90 90 |(% style="width:190px" %)VB-4T400G|(% style="width:74px" %)400|(% style="width:157px" %)785|(% style="width:188px" %)725|(% style="width:227px" %)2x240|(% style="width:305px" %)2x240|(% style="width:348px" %)GTNR 240-16 91 91 92 -= Ground wire selectio n=83 += 3 Ground wire selectio = 93 93 94 94 ~1. The terminal must be grounded reliably, and the resistance of the grounding wire must be less than 0.1Ω. Otherwise, the equipment will work abnormally or even be damaged. 95 95