... ... @@ -1,1 +1,1 @@
1 -09 Appendix A Selection Guide
1 +09 Appendix a selection guide
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Mora
Content
... ... @@ -2,13 +2,7 @@
2 2  
3 3  (% class="box infomessage" %)
4 4  (((
5 -**✎Note**
6 -
7 -0.75kW-22kW:VB default support barking unit so just install braking resistor. Please set F4.16=0,FA.03=0,FA.04=120.
8 -
9 -37kW and above:VB does not support the default barking unit, so need to install external brake unit and brake resistor. Please set F4.16=0, FA.03=0, FA.04=150.
10 -
11 -Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors.
5 +**✎Note:** Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors.
12 12  )))
13 13  
14 14  (% class="table-bordered" %)
... ... @@ -89,7 +89,7 @@
89 89  |(% style="width:190px" %)VB-4T355G/400P|(% style="width:74px" %)355/400|(% style="width:157px" %)665/785|(% style="width:188px" %)650/725|(% style="width:227px" %)2x185|(% style="width:305px" %)2x185|(% style="width:348px" %)GTNR 185-16
90 90  |(% style="width:190px" %)VB-4T400G|(% style="width:74px" %)400|(% style="width:157px" %)785|(% style="width:188px" %)725|(% style="width:227px" %)2x240|(% style="width:305px" %)2x240|(% style="width:348px" %)GTNR 240-16
91 91  
92 -= Ground wire selection =
86 += Ground wire selectio =
93 93  
94 94  ~1. The terminal must be grounded reliably, and the resistance of the grounding wire must be less than 0.1Ω. Otherwise, the equipment will work abnormally or even be damaged.
95 95