Changes for page 09 Appendix A Selection Guide
Last modified by Theodore Xu on 2025/04/12 09:37
From version 17.1
edited by Theodore Xu
on 2025/04/12 09:37
on 2025/04/12 09:37
Change comment:
There is no comment for this version
To version 15.1
edited by Theodore Xu
on 2025/03/04 16:11
on 2025/03/04 16:11
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,9 +4,9 @@ 4 4 ((( 5 5 **✎Note** 6 6 7 -0.75kW-22kW:VB default support barking unit so just install braking resistor. Please set F4.16=0,FA.03=0,FA.04=120.7 +0.75kW-22kW:VB default support barking unit so just install Braking resistor. Please set F4.16=0,FA.03=0,FA.04=120. 8 8 9 -3 0kW and above:VB does not support the default barking unit, so need to install external brake unit and brake resistor. Please set F4.16=0, FA.03=0, FA.04=150.9 +37kW and above:VB does not support the default barking unit, so need to install external brake unit and brake resistor. Please set F4.16=0, FA.03=0, FA.04=150. 10 10 11 11 Woodworking engraving machine, lifting, centrifugal drying and other industries belong to the high-frequency braking occasions recommended to use higher power braking resistors. 12 12 )))