Wiki source code of 11 VB connect Permanent magnet synchronous motor
Last modified by Wecon on 2025/09/03 21:04
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% class="box infomessage" %) | ||
2 | ((( | ||
3 | ✎Note: The inverter needs to **download the firmware version first**, after the firmware version download is completed, the inverter **can only connect to permanent magnet synchronous motors**, can't connect to asynchronous motors, and **can only use the svc mode (F0.00=0)**, the **maximum frequency** can't be more than **300HZ.** | ||
4 | ))) | ||
5 | |||
6 | == [[Download the software>>https://docs.we-con.com.cn/bin/view/VFD/Download/2%20Hardware/]] == | ||
7 | |||
8 | (% style="text-align:center" %) | ||
9 | [[image:下载目录.png]] | ||
10 | |||
11 | Enter account number and password | ||
12 | |||
13 | * Login account: WECON | ||
14 | * Password: WECAN123@ | ||
15 | |||
16 | (% style="text-align:center" %) | ||
17 | [[image:软件登录.png]] | ||
18 | |||
19 | == Firmware version == | ||
20 | |||
21 | (% class="box infomessage" %) | ||
22 | ((( | ||
23 | ✎Note: Don't check internet | ||
24 | ))) | ||
25 | |||
26 | |||
27 | (% style="text-align:center" %) | ||
28 | [[image:工具不要勾选Internet.png]] | ||
29 | |||
30 | Remote files:VB_28034_PMSM_V01.02_20200914.hex | ||
31 | |||
32 | (% class="box infomessage" %) | ||
33 | ((( | ||
34 | **[[Check out the video for the exact upgrade process. >>https://youtu.be/vubKSh741s4]]** | ||
35 | ))) | ||
36 | |||
37 | (% style="text-align:center" %) | ||
38 | [[image:选择对应的固件版本.png]] | ||
39 | |||
40 | == FF group == | ||
41 | |||
42 | After the version download is completed, you need to modify the FF group parameters of the inverter. | ||
43 | |||
44 | * Check the value of F7.11 and input the value of F7.11 to FF.00. | ||
45 | * Modify FF.01 as the corresponding power code of the inverter (contact technical support for confirmation). | ||
46 | * Modify FF.03 as the power of the inverter, for example, 18kW, FF.03=18. | ||
47 | |||
48 | == Motor self-learning == | ||
49 | |||
50 | * F0.00=0 | ||
51 | * F0.01=0 | ||
52 | * F2.00=2 | ||
53 | * F2.01-F2.05(Check the motor nameplate) | ||
54 | * F2.11=13 synchronous motor stationary tuning (calculate the reverse potential), **TUNE appears to press RUN**, wait for the self-learning is completed. | ||
55 | * Check the parameters F2.16-F2.20. |