Wiki source code of 11 VB connect Permanent magnet synchronous motor
Last modified by Wecon on 2025/09/03 21:04
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | (% class="box infomessage" %) | ||
| 2 | ((( | ||
| 3 | ✎Note: The inverter needs to **download the firmware version first**, after the firmware version download is completed, the inverter **can only connect to permanent magnet synchronous motors**, can't connect to asynchronous motors, and **can only use the svc mode (F0.00=0)**, the **maximum frequency** can't be more than **300HZ.** | ||
| 4 | ))) | ||
| 5 | |||
| 6 | == [[Download the software>>https://docs.we-con.com.cn/bin/view/VFD/Download/2%20Hardware/]] == | ||
| 7 | |||
| 8 | (% style="text-align:center" %) | ||
| 9 | [[image:下载目录.png]] | ||
| 10 | |||
| 11 | Enter account number and password | ||
| 12 | |||
| 13 | * Login account: WECON | ||
| 14 | * Password: WECAN123@ | ||
| 15 | |||
| 16 | (% style="text-align:center" %) | ||
| 17 | [[image:软件登录.png]] | ||
| 18 | |||
| 19 | == Firmware version == | ||
| 20 | |||
| 21 | (% class="box infomessage" %) | ||
| 22 | ((( | ||
| 23 | ✎Note: Don't check internet | ||
| 24 | ))) | ||
| 25 | |||
| 26 | |||
| 27 | (% style="text-align:center" %) | ||
| 28 | [[image:工具不要勾选Internet.png]] | ||
| 29 | |||
| 30 | Remote files:VB_28034_PMSM_V01.02_20200914.hex | ||
| 31 | |||
| 32 | (% class="box infomessage" %) | ||
| 33 | ((( | ||
| 34 | **[[Check out the video for the exact upgrade process. >>https://youtu.be/vubKSh741s4]]** | ||
| 35 | ))) | ||
| 36 | |||
| 37 | (% style="text-align:center" %) | ||
| 38 | [[image:选择对应的固件版本.png]] | ||
| 39 | |||
| 40 | == FF group == | ||
| 41 | |||
| 42 | After the version download is completed, you need to modify the FF group parameters of the inverter. | ||
| 43 | |||
| 44 | * Check the value of F7.11 and input the value of F7.11 to FF.00. | ||
| 45 | * Modify FF.01 as the corresponding power code of the inverter (contact technical support for confirmation). | ||
| 46 | * Modify FF.03 as the power of the inverter, for example, 18kW, FF.03=18. | ||
| 47 | |||
| 48 | == Motor self-learning == | ||
| 49 | |||
| 50 | * F0.00=0 | ||
| 51 | * F0.01=0 | ||
| 52 | * F2.00=2 | ||
| 53 | * F2.01-F2.05(Check the motor nameplate) | ||
| 54 | * F2.11=13 synchronous motor stationary tuning (calculate the reverse potential), **TUNE appears to press RUN**, wait for the self-learning is completed. | ||
| 55 | * Check the parameters F2.16-F2.20. |