1 +○——It indicates that the set value of the parameter can be changed when the inverter is shut down or running.
2 +
3 +●——It indicates that the setting value of the parameter cannot be changed when the inverter is in operation;
4 +
5 +◎——It indicates that the value of the parameter is the actual detection record value and cannot be changed;
6 +
7 +□——It indicates that the parameter is Manufacturer parameter, which can only be set by the manufacturer and cannot be operated by users.
8 +
9 +
10 +Mailing address description:
11 +
12 +The following table indicates the communication addresses in hexadecimal format.
13 +
14 +In the following table, the communication address is the RAM address, and the parameter is not saved if the power fails, you need to save, please see the instructions for writing EEPROM in section 7.4.
15 +
16 +
17 +6.1 Basic parameter set
18 +
19 +|**Function code**|**Name**|**Setting range**|**Default**|**Property**|**Modbus address**
20 +|(% colspan="6" %)**F0 Basic function parameter group**
21 +|F0.00|Motor control mode|(((
22 +0: SVC
23 +
24 +1: V/F
25 +
26 +2: -
27 +)))|1|●|0x0000
28 +|F0.01|Command source selection|(((
29 +0: Operation panel command channel
30 +
31 +1: Terminal command channel
32 +
33 +2: Serial port communication command channel
34 +)))|0|●|0x0001
35 +|F0.02| UP/DOWN standard|(((
36 +0: Operating frequency
37 +
38 +1: Set frequency
39 +)))|1|●|0x0002
40 +|F0.03|Primary frequency source X selection|(((
41 +0: Digital setting F0.08 (Adjustable terminal UP/DOWN, non-relative after power failure)
42 +
43 +1: Digit setting F0.08 (Terminal
44 +
45 +UP/DOWN adjustable, power down memory)
46 +
47 +2: AI1
48 +
49 +3: AI2
50 +
51 +4: Keyboard potentiometer set
52 +
53 +5: The terminal PULSE pulse is set
54 +
55 +6: Multi-speed instruction
56 +
57 +7: Simple PLC
58 +
59 +8: PID
60 +
61 +9: Communication setting
62 +
63 +10: AI3(Expansion module)
64 +)))|4|●|0x0003
65 +|F0.04|Auxiliary frequency source Y selection|Same as F0.03|0|●|0x0004
66 +|F0.05|Range of auxiliary frequency source Y|(((
67 +0: Relative to the maximum frequency F0.10
68 +
69 +1: Relative to the frequency source X
70 +)))|0|○|0x0005
71 +|F0.06|Auxiliary frequency source Y range in superposition|0% to 150%|100%|○|0x0006
72 +|F0.07|Frequency source operation selection|(((
73 +LED ones: Frequency source
74 +
75 +selection
76 +
77 +0: The primary frequency source
78 +
79 +1: The result of primary and secondary operations
80 +
81 +2: Switch between primary frequency source and secondary frequency source
82 +
83 +3: Switch between the primary frequency source and the primary and secondary operation results
84 +
85 +4: Switch between auxiliary frequency source and primary and secondary operation results
86 +
87 +LED ten: Frequency source main and auxiliary operation relationship
88 +
89 +0: Primary + secondary
90 +
91 +1: Primary to secondary
92 +
93 +2: Indicates the maximum value of both
94 +
95 +3: The minimum value of both
96 +
97 +4: Main*auxiliary
98 +)))|0|○|0x0007
99 +|F0.08|Keyboard setting frequency|(((
100 +0.00Hz to Maximum frequency
101 +
102 +F0.10
103 +)))|50.00Hz|○|0x0008
104 +|F0.09|Running direction selection|(((
105 +0: The same direction
106 +
107 +1: The direction is reversed
108 +
109 +2: Reverse prohibition
110 +)))|0|○|0x0009
111 +|F0.10|Maximum output frequency|0.00Hz to 320.00Hz|50.00Hz|●|0x000A
112 +|F0.11|Source of frequency upper limit|(((
113 +0: The number is given F0.12
114 +
115 +1: AI1
116 +
117 +2: AI2
118 +
119 +3: AI3
120 +
121 +4: Set the terminal PULSE
122 +
123 +5: Communication setting
124 +
125 +6: Reservations
126 +
127 +7: Keyboard potentiometer set
128 +)))|0|●|0x000B
129 +|F0.12|Upper limiting frequency|F0.14 to F0.10|50.00Hz|○|0x000C
130 +|F0.13|Upper frequency bias|0.00Hz to F0.10|0.00Hz|○|0x000D
131 +|F0.14|Lower frequency|0.00Hz to F0.12|0.00Hz|○|0x000E
132 +|F0.15|Lower frequency operating mode|(((
133 +0: Run at lower frequency
134 +
135 +1: STOP
136 +
137 +2: Zero speed operation
138 +)))|0|○|0x000F
139 +|F0.16|Carrier frequency|0.5kHz to 16.0kHz|Model determination|○|0x0010
140 +|F0.17|Carrier PWM characteristic selection|(((
141 +Bits: Select PWM mode
142 +
143 +0: Automatic switching;
144 +
145 +1: 7 waves;
146 +
147 +2: 5 waves;
148 +
149 +3: SPWM;
150 +
151 +LED ten: Carrier is associated with the output frequency
152 +
153 +0: Independent of output frequency
154 +
155 +1: It depends on the output frequency
156 +
157 +LED hundred: random PWM depth
158 +
159 +0: OFF
160 +
161 +1-8: Open, adjust depth
162 +
163 +LED kilobit: Over modulation option
164 +
165 +0: OFF
166 +
167 +1: ON
168 +)))|1010|●|0x0011
169 +|F0.18|Acceleration time 1|0.0s to 6500.0s|Model determination|○|0x0012
170 +|F0.19|Deceleration time1|0.0s to 6500.0s|Model determination|○|0x0013
171 +|F0.20|Parameter initialization|(((
172 +0: No action is taken
173 +
174 +1: Restore factory value (Do not restore motor parameters)
175 +
176 +2: Clear the record information
177 +
178 +3: Restore factory value (Restore motor parameters)
179 +)))|0|●|0x0014
180 +|F0.23|Unit of acceleration and deceleration time|(((
181 +0: 1 s
182 +
183 +1: 0.1s
184 +
185 +2: 01s
186 +)))|1|●|0x0017
187 +|F0.24|Acceleration and deceleration time reference frequency|(((
188 +0: Maximum frequency (F0.10)
189 +
190 +1: Set the frequency
191 +
192 +2: 100 Hz
193 +)))|0|●|0x0018
194 +|F0.25|Fan control|(((
195 +Bits: Start/stop control
196 +
197 +0: The fan runs after the inverter is powered on
198 +
199 +1: Shutdown is related to temperature, and operation is running
200 +
201 +2: Stop The fan stops, and the operation is related to temperature
202 +
203 +Tens place: Enables the speed adjustment function
204 +
205 +0: Off
206 +
207 +1: Enable
208 +)))|01|○|0x0019
209 +|F0.26|Frequency command decimal point|(((
210 +1: 1 decimal place
211 +
212 +2: 2 decimal places
213 +)))|2|●|0x001A
214 +|F0.27|Modulation ratio coefficient|10.0-150.0%|100.0%|○|0x001B
215 +|(% colspan="6" %)**F1 Start stop control parameter group**
216 +|F1.00|Start-up operation mode|(((
217 +LED bits: Boot mode
218 +
219 +0: Start directly from the start frequency
220 +
221 +1: Start after speed tracking and direction judgment
222 +
223 +2: The asynchronous machine starts with pre-excitation
224 +)))|00|●|0x0100
225 +|F1.01|Speed tracking mode|(((
226 +LED ten: Speed tracking direction
227 +
228 +0: One to the stop direction
229 +
230 +1: One to the starting direction
231 +
232 +2: Automatic search
233 +)))|0|●|0x0101
234 +|F1.02|Speed tracking time|0.01 to 60.00s|1.00s|○|0x0102
235 +|F1.03|Speed tracking current loop gain|0.00-100.00|10.00|○|0x0103
236 +|F1.04|RPM tracking speed gain|0.01 to 10.00|2.00|○|0x0104
237 +|F1.05|Speed tracking current|50 to 200%|150%|○|0x0105
238 +|F1.06|Starting frequency|0.00-60.00Hz|0.00Hz|○|0x0106
239 +|F1.07|Startup frequency duration|0.0-50.0s|0.0s|●|0x0107
240 +|F1.08|Braking current before starting|0.0-150.0%|80.0%|●|0x0108
241 +|F1.09|Braking time before starting|0.0-60.0s|0.0s|●|0x0109
242 +|F1.10|Stop method|(((
243 +0: Slow down and stop
244 +
245 +1: Free shutdown
246 +)))|0|○|0x010A
247 +|F1.11|Stop DC braking start frequency|0.00Hz -F0.10|0.00Hz|○|0x010B
248 +|F1.12|Stop DC braking wait time|0.0s to 100.0s|0.0s|○|0x010C
249 +|F1.13|Stop DC braking current|0.0% to 150.0%|80.0%|○|0x010D
250 +|F1.14|Stop DC braking duration|0.0s to 100.0s|0.0s|○|0x010E
251 +|F1.16|Energy consumption brake action voltage|115.0%-140.0%|130%|●|0x0110
252 +|F1.17|Magnetic flux braking gain|10-150%|80%|○|0x0111
253 +|F1.18|Magnetic flux braking operating voltage|110%-500%|120%|○|0x0112
254 +|F1.19|Flux brake limiting|0-200%|20%|○|0x0113
255 +|F1.20|Acceleration and deceleration selection|(((
256 +0: Straight line
257 +
258 +1: S curve
259 +)))|0|●|0x0114
260 +|F1.21|S-curve initial acceleration rate|20.0%-100.0%|50.0%|●|0x0115
261 +|F1.22|S-curve initial deceleration rate|20.0%-100.0%|50.0%|●|0x0116
262 +|F1.23|Zero speed holding torque|0.0-150.0%|0|●|0x0117
263 +|F1.24|Zero speed holding torque time|(((
264 +0.0 to 6000.0s
265 +
266 +If the value is set to 6000.0s, the value remains unchanged without time limit.
267 +)))|Model determination|●|0x0118
268 +|F1.25|Start pre-excitation time|0.00-60.00s|0.20|○|0x0119
269 +|F1.26|Shutdown frequency|0.00-60.00Hz|0.00Hz|○|0x011A
270 +|F1.27|Power failure restart action selection|(((
271 +0: Invalid
272 +
273 +1: Valid
274 +)))|0|○|0x011B
275 +|F1.28|Power failure restart waiting time|0.00-120.00s|0.50s|○|0x011C
276 +|F1.29|Select the terminal running protection|(((
277 +LED bits: Select the terminal run instruction when powering on
278 +
279 +0: The terminal running instruction is invalid during power-on.
280 +
281 +1: Terminal running instructions are valid during power-on
282 +
283 +LED ten: Run command given channel switch terminal run instruction selection
284 +
285 +0: The terminal running instruction is invalid
286 +
287 +1: The terminal instruction is valid when the terminal is cut in.
288 +)))|11|○|0x011D
289 +|(% colspan="6" %)**F2 Motor parameter group**
290 +|F2.00|Motor type|(((
291 +0: Asynchronous machine (AM)
292 +
293 +1: Permanent magnet synchronous motor(PM)
294 +
295 +2: Single-phase induction motor (VF control only)
296 +)))|0|●|0x0200
297 +|F2.01|Rated power of motor|0.1kW to 400.0kW|(% rowspan="10" %)Model determination|●|0x0201
298 +|F2.02|Rated voltage of motor|1V to 440V|●|0x0202
299 +|F2.03|Rated current of motor|0.1-2000.0A|●|0x0203
300 +|F2.04|Rated frequency of motor|0.01Hz -F0.10|●|0x0204
301 +|F2.05|Rated motor speed|1rpm to 65000rpm|●|0x0205
302 +|F2.06|Motor stator resistance|0.001-65.000|●|0x0206
303 +|F2.07|Motor rotor resistance|0.001-65.000|●|0x0207
304 +|F2.08|Motor fixed rotor inductance|0.1-6500.0mH|●|0x0208
305 +|F2.09|Mutual inductance of motor fixed rotor|0.1-6500.0mH|●|0x0209
306 +|F2.10|Motor no-load current|0.1-650.0A|●|0x020A
307 +|F2.11|Tuning selection|(((
308 +0: No operation is performed
309 +
310 +1: Static tuning 1
311 +
312 +2: Full tuning
313 +
314 +3: Static tuning 2(AM calculated Lm)
315 +)))|0|●|0x020B
316 +|F2.12|G/P model|(((
317 +0: Type G machine
318 +
319 +1: P-type machine
320 +)))|Model determination|◎|0x020C
321 +|F2.13|Single-phase motor turns ratio|10 -200%|100%|●|0x020D
322 +|F2.14|Current calibration coefficient of single-phase motor|50 -200%|120%|●|0x020E
323 +|F2.15|Number of motor poles|2-48|4|●|0x020F
324 +|F2.16|Speed feedback or encoder type|(((
325 +Units place: encoder type
326 +
327 +0: Expansion interface for IO module
328 +
329 +1: Standard ABZ encoder
330 +
331 +2: Resolver
332 +
333 +3: UVW encoder
334 +
335 +4: UVW encoder with reduced wiring
336 +
337 +Tens place: encoder Direction
338 +
339 +0: Direction same
340 +
341 +1: Direction opposite
342 +
343 +Hundreds place: break Detection
344 +
345 +0: Disable
346 +
347 +1: Enable
348 +
349 +Thousands Digit: Reserved
350 +)))|0|●|0x0210
351 +|F2.17|Photoelectric encoder line count|0-60000|2500|●|0x0211
352 +|F2.18|PG disconnection detection time|0.000-60.000s|0.100sec|○|0x0212
353 +|F2.19|Resolver pole pairs|2-128|2|●|0x0213
354 +|F2.20|Encoder installation reduction ratio|0.100-50.000|1.000|●|0x0214
355 +|F2.21|Encoder filter time|1-1000ms|10ms|●|0x0215
356 +|F2.22|Stator resistance of synchronization|0.001-65.000 (0.0010hm)|(% rowspan="4" %)Model determination|●|0x0216
357 +|F2.23|Synchronize d-axis inductance|0.01mH-655.35mH|●|0x0217
358 +|F2.24|Synchronize Q-axis inductance|0.01mH-655.35mH|●|0x0218
359 +|F2.25|Synchronize back electromotive force|0.1V-1000.0V|○|0x0219
360 +|F2.28|High frequency injection voltage|0.1% to 100.0%|20.0%|●|0x021C
361 +|F2.29|Back potential identification current|0.1% to 100.0%|50.0%|●|0x021D
362 +|F2.31|Asynchronous no-load current per unit value|0.1%|(% rowspan="9" %)Model determination|●|0x021F
363 +|F2.32|Per unit asynchronous stator resistance|0.01%|●|0x0220
364 +|F2.33|Asynchronous rotor resistance per unit value|0.01%|●|0x0221
365 +|F2.34|Asynchronous mutual inductance per unit value|0.1%|●|0x0222
366 +|F2.35|Asynchronous leakage sensing per unit value|0.01%|●|0x0223
367 +|F2.36|Per unit value of asynchronous leakage sensing coefficient|0.01%|●|0x0224
368 +|F2.37|Synchronous stator resistance per unit value|0.01%|●|0x0225
369 +|F2.38|Per unit value of synchronous D-axis inductance|0.01%|●|0x0226
370 +|F2.39|Synchronous Q-axis inductance per unit value|0.01%|●|0x0227
371 +|F2.40|Back electromotive force of synchronous motor|0.1V|300.0V|●|0x0228
372 +|F2.41|Encoder mounting angle|0.1 °|0.0 °|●|
373 +|(% colspan="6" %)**F3 Vector control parameter group**
374 +|F3.00|ASR (Speed loop) proportional gain 1|0.00 to 100.00%|20%|○|0x0300
375 +|F3.01|ASR (Velocity ring) integration time 1|0.01s to 10.00s|0.20|○|0x0301
376 +|F3.02|Loss of velocity protection value|(((
377 +0 to 5000ms
378 +
379 +(0 Turn off stall protection)
380 +)))|0ms|○|0x0302
381 +|F3.03|ASR filtering time 1|0.000 to 0.100s|0.000s|○|0x0303
382 +|F3.04|ASR switching frequency 1|0.00 to 50.00Hz|5.00Hz|○|0x0304
383 +|F3.05|ASR (Speed loop) proportional gain 2|0.00 to 100.00%|20%|○|0x0305
384 +|F3.06|ASR (Velocity loop) integration time 2|0.01s to 10.00s|0.30|○|0x0306
385 +|F3.07|Retain| |0|-|0x0307
386 +|F3.08|ASR filtering time 2|0.000-0.100s|0.000s|○|0x0308
387 +|F3.09|ASR switching frequency 2|0.00-50.00Hz|10.00Hz|●|0x0309
388 +|F3.10|Slip compensation coefficient|0-250%|100%|●|0x030A
389 +|F3.11|Maximum electric torque|0.0-250.0%|160.0%|○|0x030B
390 +|F3.12|Maximum generating torque|0.0-250.0%|160.0%|○|0x030C
391 +|F3.16|Current loop D axis proportional gain|0.1 to 10.0|1.0|●|0x0310
392 +|F3.17|Current loop D axis integral gain|0.1 to 10.0|1.0|○|0x0311
393 +|F3.18|Current loop Q axis proportional gain|0.1 to 10.0|1.0|○|0x0312
394 +|F3.19|Current loop Q axis integral gain|0.1 to 10.0|1.0|○|0x0313
395 +|F3.20|D-axis feed-forward gain|0.0-200.0%|50.0%|○|0x0314
396 +|F3.21|Q-axis feed-forward gain|0.0-200.0%|50.0%|○|0x0315
397 +|F3.22|Optimize the current loop bandwidth|0.0 to 99.99ms|2.00ms|○|0x0316
398 +|F3.23|Current loop control word|0 to 65535|0|○|0x0317
399 +|F3.24|Weak magnetic control current upper limit|0 to 200%|50%|●|0x0318
400 +|F3.25|Weak magnetic control feed forward gain|0 to 500%|0%|●|0x0319
401 +|F3.26|Weak magnetic control proportional gain|0 to 9999|500|○|0x031A
402 +|F3.27|Weak magnetic control integral gain|0 to 9999|1000|○|0x031B
403 +|F3.28|MTPA gain|0.0 to 500.0%|0.0%|○|0x031C
404 +|F3.29|MTPA filtering time|0.0 to 999.9ms|100.0ms|○|0x031D
405 +|F3.30|Magnetic flux compensation coefficient|0-500%|100%|○|0x031E
406 +|F3.31|Open-loop vector observeration gain|0 to 9999|1024|○|0x031F
407 +|F3.32|Open loop vector observation filtering time|1 to 100ms|20ms|○|0x0320
408 +|F3.33|Open-loop vector compensates start frequency|0 to 100.0%|1.0%|○|0x0321
409 +|F3.34|Open loop vector control word|0 to 9999|8|○|0x0322
410 +|F3.35|Synchronous open loop starting mode|(((
411 +0: Direct startup.
412 +
413 +1: Start at an Angle
414 +)))|0|○|0x0323
415 +|F3.36|Dc pull in time|1ms to 9999ms|500ms|○|0x0324
416 +|F3.37|Synchronous open loop vector low-frequency boost|0-100.0%|20.0%|○|0x0325
417 +|F3.38|Synchronous open loop vector high-frequency boost|0.0-100.0%|0.0%|○|0x0326
418 +|F3.39|Low frequency boost to maintain frequency|0.0-100.0%|10.0%|○|0x0327
419 +|F3.40|Low frequency increases cutoff frequency|0.0-100.0%|20.0%|○|0x0328
420 +|F3.46|Speed/torque control mode|(((
421 +0: Speed control
422 +
423 +1: Torque control
424 +)))|0|●|0x032E
425 +|F3.47|Torque given channel selection|(((
426 +0: F3.48 is set
427 +
428 +1: AI1╳F3.48
429 +
430 +2: AI2╳F3.48
431 +
432 +3: AI3╳F3.48
433 +
434 +4: PUL╳F3.48
435 +
436 +5: Keyboard potentiometer given ╳F7.01
437 +
438 +6: RS485 communication given ╳F3.48
439 +)))|0|●|0x032F
440 +|F3.48|Torque keyboard numeric setting|0 to 200.0%|100.0%|○|0x0330
441 +|F3.49|Torque direction selection|(((
442 +Units: Torque direction setting
443 +
444 +0: The torque direction is positive
445 +
446 +1: The torque direction is negative
447 +
448 +Tens place: torque reversing setting
449 +
450 +0: Torque reversal is allowed
451 +
452 +1: Torque reversal is prohibited
453 +)))|00|○|0x0331
454 +|F3.50|Upper limit of output torque|F3.51 to 200.0%|150.0%|○|0x0332
455 +|F3.51|Lower limit of output torque|0 to F3.50|0%|○|0x0333
456 +|F3.52|Torque control forward speed limit selection|(((
457 +0: F3.54 is set
458 +
459 +1: AI1╳F3.54
460 +
461 +2: AI2╳F3.54
462 +
463 +3: AI3╳F3.54
464 +
465 +4: PUL╳F3.54
466 +
467 +5: Keyboard potentiometer given ╳F3.54
468 +
469 +6: RS485 communication given ╳F3.54
470 +)))|0s|○|0x0334
471 +|F3.53|Torque control reversal speed limit selection|(((
472 +0: F3.55 is set
473 +
474 +1: AI1╳F3.55
475 +
476 +2: AI2╳F3.55
477 +
478 +3: AI3╳F3.55
479 +
480 +4: PUL╳F3.55
481 +
482 +5: Keyboard potentiometer given ╳F3.55
483 +
484 +6: RS485 communication given ╳F3.55
485 +
486 +7: Purchase card
487 +)))|0|○|0x0335
488 +|F3.54|Torque control positive maximum speed limit|0.00 to upper limiting frequency|50.00Hz|○|0x0336
489 +|F3.55|Torque control reversal maximum speed limit|0.00 to upper limiting frequency|50.00Hz|○|0x0337
490 +|F3.56|Speed/torque switching delay|0.00 to 10.00s|0.01s|○|0x0338
491 +|F3.57|Torque acceleration time|0.00 to 10.00s|0.01s|○|0x0339
492 +|F3.58|Torque deceleration time|0.00 to 10.00s|0.01s|○|0x033A
493 +|F3.59|Forward and reverse torque dead zone time|0.00 to 650.00s|0.00s|○|0x033B
494 +|(% colspan="6" %)**F4 V/F control parameter group**
495 +|F4.00|Linear VF curve selection|(((
496 +0: Linear V/F curve;
497 +
498 +1: Multi-point V/F curve
499 +
500 +2: Square V/F curve
501 +
502 +3-11: 1.1-1.9 power VF curves, respectively;
503 +
504 +12: V/F fully separated mode
505 +)))|0|●|0x0400
506 +|F4.01|Manual torque lift|0.1-30.0%, 0 automatic torque boost|Model determination|○|0x0401
507 +|F4.02|Torque boost cutoff frequency|0.00Hz -F0.10|50.00Hz|●|0x0402
508 +|F4.03|Self-set frequency F1|0.00Hz to F4.05|3.00Hz|●|0x0403
509 +|F4.04|Self-set voltage V1|0.0% to 100.0%|10.0%|●|0x0404
510 +|F4.05|Self-set frequency F2|F4.03 to F4.07|5.00Hz|●|0x0405
511 +|F4.06|Self-set voltage V2|0.0% to 100.0%|15.0%|●|0x0406
512 +|F4.07|Self-set frequency F3|F4.05-F4.09|8.00Hz|●|0x0407
513 +|F4.08|Self-set voltage V3|0.0% to 100.0%|22.0%|●|0x0408
514 +|F4.09|Self-set frequency F4|F4.07-Rated frequency of motor F2.04|12.00Hz|●|0x0409
515 +|F4.10|Self-set voltage V4|0.0% to 100.0%|31.0%|●|0x040A
516 +|F4.11|Oscillation suppression gain|0.0 to 10.0|Model determination|○|0x040B
517 +|F4.12|Oscillation suppression filtering time|1 to 1000ms|50ms|○|0x040C
518 +|F4.14|Percentage of output voltage|25-100%|100%|●|(((
519 +
520 +
521 +0x040E
522 +)))
523 +|F4.16|(((
524 +AVR function
525 +
526 +
527 +)))|(((
528 +0: Invalid
529 +
530 +1: Only slowing down is not effective
531 +
532 +2: Only constant speed is effective
533 +
534 +3: Valid
535 +)))|3|●|0x0410
536 +|F4.17|EVF torque boost gain|0 to 500.0%|50.0%|○|0x0411
537 +|F4.18|EVF torque boost filtering time|1 to 1000ms|20ms|○|0x0412
538 +|F4.19|EVF slip compensation gain|0 to 500.0%|0.0%|○|0x0413
539 +|F4.20|EVF slip compensation filtering time|1 to 1000ms|100ms|○|0x0414
540 +|F4.21|Automatic energy saving selection|(((
541 +Units bit: 0 is off, 1 is on
542 +
543 +Tens: Frequency change exit depth
544 +
545 +Hundreds place: Reserve
546 +
547 +Thousands: Reserve
548 +)))|50|○|0x0415
549 +|F4.22|Lower limit frequency of energy saving operation|0.0-100.0%|25.0%|○|0x0416
550 +|F4.23|Energy saving and pressure reduction time|0.1-5000.0s|10.0s|○|0x0417
551 +|F4.24|Lower limit of energy saving and pressure reduction|20.0-100.0%|30.0%|○|0x0418
552 +|F4.25|Energy saving and pressure reduction rate|1 to 1000V/s|50V/s|○|0x0419
553 +|F4.26|Voltage regulated proportional gain|0 to 100|20|○|0x041A
554 +|F4.27|Voltage regulation integral gain|0 to 100|20|○|0x041B
555 +|F4.30|Stabilizer proportional gain|0.1% to 100.0%|10.0%|○|0x041E
556 +|F4.31|Stabilizer filtering time|1ms to 1000ms|50ms|○|0x041F
557 +|F4.32|Low frequency current lift|0.0% to 200.0%|100.0%|○|0x0420
558 +|F4.33|Low frequency boost maintenance frequency|0 to 100.0%|10.0%|○|0x0421
559 +|F4.34|Low frequency current boosts the cutoff frequency|0 to 100.0%|30.0%|○|0x0422
560 +|F4.35|D-axis current gain|0.0 to 100.0|2.0|○|0x0423
561 +|F4.36|Q-axis current gain|0.0 to 100.0|2.0|○|0x0424
562 +|F4.37|Magnetic flux set strength|0 to 500%|30%|○|0x0425
563 +|F4.38|Magnetic flux control proportional gain|0 to 9999|500|○|0x0426
564 +|F4.39|Magnetic flux controls the integral gain|0 to 9999|500|○|0x0427
565 +|F4.40|Dc pull in time|1ms to 9999ms|1000ms|○|0x0428
566 +|F4.41|Starting frequency|0.00Hz to 99.00Hz|3.00Hz|○|0x0429
567 +|F4.42|Starting frequency time|0.0s- 999.0s|3.0s|○|0x042A
568 +|F4.43|V/F Separate the output voltage source|(((
569 +0: Function code F0.27 set
570 +
571 +1: AI1 is set
572 +
573 +2: AI2 is set
574 +
575 +3: Reservations
576 +
577 +4: Set the terminal PULSE
578 +
579 +5: Multi-speed
580 +
581 +6: Simple PLC
582 +
583 +7: PID
584 +
585 +8: Communication is given 100% corresponding to the rated voltage of the motor
586 +)))|0|○|0x042B
587 +|F4.44|V/F separation output voltage digital setting|0.0% to 100.0%|0|○|0x042C
588 +|F4.45|V/F separation voltage rise time|0.0-1000.0s|1.0|○|0x042D
589 +|F4.46|V/F separation voltage drop time|0.0-1000.0s|1.0|○|0x042E
590 +|F4.47|V/F separate stop mode|(((
591 +0: The voltage/frequency is simultaneously reduced to 0;
592 +
593 +1: The frequency decreases after the voltage drops to 0
594 +)))|0|○|0x042F
595 +|(% colspan="6" %)**F5 Enter the terminal parameter group**
596 +|F5.00|DI1 Terminal function selection|(% rowspan="8" %)(((
597 +0: Non-function
598 +
599 +0: Non-function
600 +
601 +1: FWD
602 +
603 +2: REV
604 +
605 +3: Three-wire operation control
606 +
607 +4: FJOG
608 +
609 +5: RJOG
610 +
611 +6: Terminal UP
612 +
613 +7: Terminal DOWN
614 +
615 +8: Free break
616 +
617 +9: RESET
618 +
619 +10: Running pause
620 +
621 +11: External fault input(NO)
622 +
623 +12: Multi-speed instruction terminal 1
624 +
625 +13: Multi-speed instruction terminal 2
626 +
627 +14: Multi-speed instruction terminal 3
628 +
629 +15: Multi-speed instruction terminal 4
630 +
631 +16: Acceleration and deceleration time select terminal 1
632 +
633 +17: Acceleration and deceleration time select terminal 2
634 +
635 +18: Frequency source switching (terminal, keyboard)
636 +
637 +19: The UP/DOWN setting clears zero
638 +
639 +20: Run the command to switch terminals
640 +
641 +21: Acceleration and deceleration prohibition
642 +
643 +22: PID pause
644 +
645 +23: PLC State reset
646 +
647 +24: Swing pause
648 +
649 +25: Counter input
650 +
651 +26: Counter reset
652 +
653 +27: Length count input
654 +
655 +28: Length reset
656 +
657 +29: Torque control prohibited
658 +
659 +30: PULSE impulse input(only DI4)
660 +
661 +31: Reverse
662 +
663 +32: Immediate DC braking
664 +
665 +33: The external fault is normally closed
666 +
667 +34: Reverse
668 +
669 +35: The direction of PID action is reversed
670 +
671 +36: External parking terminal 1
672 +
673 +37: Control command switching terminal
674 +
675 +38: PID integration pause terminal
676 +
677 +39: Main frequency source and preset frequency switching terminal
678 +
679 +40: Auxiliary frequency source and preset frequency switching terminal
680 +
681 +41: Retain
682 +
683 +42: Retain
684 +
685 +43: PID parameter switching terminal
686 +
687 +44: User-defined fault 1
688 +
689 +45: User-defined fault 2
690 +
691 +46: Speed control/torque control switch
692 +
693 +47: Emergency stop
694 +
695 +48: External parking terminal 2
696 +
697 +49: Decelerate DC braking
698 +
699 +50: The running time is cleared
700 +
701 +51: Timing enable
702 +
703 +52: Timing reset
704 +)))|1|●|0x0500
705 +|F5.01|DI2 Terminal function selection|2|●|0x0501
706 +|F5.02|DI3 Terminal function selection|9|●|0x0502
707 +|F5.03|DI4 Terminal function selection|12|●|0x0503
708 +|F5.04|DI5 Terminal function selection (Extension)|0|●|0x0504
709 +|F5.05|DI6 Terminal function selection (Extension)|0|●|0x0505
710 +|F5.08|AI1 Indicates the DI terminal function|0|●|0x0508
711 +|F5.09|AI2 Indicates the DI terminal function|0|●|0x0509
712 +|F5.10|AI1 Input selection|(((
713 +0: 0-10V
714 +
715 +3: 0-5V
716 +
717 +4: 0.5-4.5V
718 +)))|0|●|0x050A
719 +|F5.11|AI2 Input selection|(((
720 +0: 0-10V
721 +
722 +1: 4-20mA
723 +
724 +2: 0-20mA
725 +
726 +3: 0-5V
727 +
728 +4: 0.5-4.5V
729 +)))|1|●|0x050B
730 +|F5.12|VDI1 terminal function selection|(% rowspan="3" %)(((
731 +0: Non-function
732 +
733 +1: FWD
734 +
735 +2: REV
736 +
737 +3: Three-wire operation control
738 +
739 +4: FJOG
740 +
741 +5: RJOG
742 +
743 +6: Terminal UP
744 +
745 +7: terminal DOWN
746 +
747 +8: Free break
748 +
749 +9: RESET
750 +
751 +10: Running pause
752 +
753 +11: External fault input(NO)
754 +
755 +12: Multi-speed instruction terminal 1
756 +
757 +13: Multi-speed instruction terminal 2
758 +
759 +14: Multi-speed instruction terminal 3
760 +
761 +15: Multi-speed instruction terminal 4
762 +
763 +16: Acceleration and deceleration time select terminal 1
764 +
765 +17: Acceleration and deceleration time select terminal 2
766 +
767 +18: Frequency source switching (terminal, keyboard)
768 +
769 +19: The UP/DOWN setting clears zero
770 +
771 +20: Run the command to switch terminals
772 +
773 +21: Acceleration and deceleration prohibition
774 +
775 +22: PID pause
776 +
777 +23: PLC State reset
778 +
779 +24: Swing pause
780 +
781 +25: Counter input
782 +
783 +26: Counter reset
784 +
785 +27: Length count input
786 +
787 +28: Length reset
788 +
789 +29: Torque control prohibited
790 +
791 +30: PULSE impulse input(only DI4)
792 +
793 +31: Reverse
794 +
795 +32: Immediate DC braking
796 +
797 +33: The external fault is normally closed
798 +
799 +34: Reverse
800 +
801 +35: The direction of PID action is reversed
802 +
803 +36: External parking terminal 1
804 +
805 +37: Control command switching terminal
806 +
807 +38: PID integration pause terminal
808 +
809 +39: Main frequency source and preset frequency switching terminal
810 +
811 +40: Auxiliary frequency source and preset frequency switching terminal
812 +
813 +41: Reverse
814 +
815 +42: Reverse
816 +
817 +43: PID parameter switching terminal
818 +
819 +44: User-defined fault 1
820 +
821 +45: User-defined fault 2
822 +
823 +46: Speed control/torque control switch
824 +
825 +47: Emergency stop
826 +
827 +48: External parking terminal 2
828 +
829 +49: Decelerate DC braking
830 +
831 +50: The running time is cleared
832 +
833 +51: Timing enable
834 +
835 +52: Timing reset
836 +)))|0|●|0x050C
837 +|F5.13|VDI2 terminal function selection|0|●|0x050D
838 +|F5.14|VDI3 terminal function selection|0|●|0x050E
839 +|F5.15|DI filtering time|0.000s to 1.000s|0.010s|○|0x050F
840 +|F5.16|Terminal command mode|(((
841 +0: Two-wire type 1
842 +
843 +1: Two-wire type 2
844 +
845 +2: Three-wire type 1
846 +
847 +3: Three-wire type 2
848 +)))|0|●|0x0510
849 +|F5.17|UP/DOWN change rate|0.01Hz to 655.35Hz|0.50Hz|○|0x0511
850 +|F5.18|AI1 minimum input|0.00V to F5.20|0.00V|○|0x0512
851 +|F5.19|AI1 minimum input setting|-100.0% to +100.0%|0%|○|0x0513
852 +|F5.20|AI1 maximum input|F5.18 to +10.00V|10.00V|○|0x0514
853 +|F5.21|AI1 maximum input setting|-100.0% to +100.0%|100.0%|○|0x0515
854 +|F5.22|AI1 filtering time|0.00s to 10.00s|0.10s|○|0x0516
855 +|F5.23|AI2 minimum input|-10.00V to F5.25|2.00V|○|0x0517
856 +|F5.24|AI2 minimum input setting|-100.0% to +100.0%|0%|○|0x0518
857 +|F5.25|AI2 maximum input|F5.23 to +10.00V|10.00V|○|0x0519
858 +|F5.26|AI2 maximum input setting|-100.0% to +100.0%|100.0%|○|0x051A
859 +|F5.27|AI2 filtering time|0.00s to 10.00s|0.10s|○|0x051B
860 +|F5.28|PULSE|0.00 to F5.30|0.00kHz|○|0x051C
861 +|F5.29|PULSE input minimum frequency setting|0.00-100.00%|0%|○|0x051D
862 +|F5.30|PULSE input maximum frequency|F5.28-50.00kHz|20.00kHz|○|0x051E
863 +|F5.31|PULSE maximum frequency setting|0.00-100.00%|100.0%|○|0x051F
864 +|F5.32|PULSE filtering time|0.00-10.00s|0.10s|○|0x0520
865 +|F5.33|DI1 Enable delay time|0.0s to 360.0s|0.0s|○|0x0521
866 +|F5.34|DI2 Enable delay time|0.0s to 360.0s|0.0s|○|0x0522
867 +|F5.35|DI1 Forbidden delay time|0.0s to 360.0s|0.0s|○|0x0523
868 +|F5.36|DI2 Forbidden delay time|0.0s to 360.0s|0.0s|○|0x0524
869 +|F5.37|Enter terminal valid status setting 1|(((
870 +0: Low level valid
871 +
872 +1: High level valid
873 +
874 +LED one place: D1 terminal
875 +
876 +LED tens place: D2 terminal
877 +
878 +LED hundreds place: D3 terminal
879 +
880 +LED thousands place: D4 terminal
881 +)))|0|●|0x0525
882 +|F5.38|Enter terminal valid status setting 2|(((
883 +0: Low level valid
884 +
885 +1: High level valid
886 +
887 +LED one place: D5 terminal(expend)
888 +
889 +LED tens place: D6 terminal(expend)
890 +)))|0|●|0x0526
891 +|F5.39|Enter terminal valid status setting 3|(((
892 +0: Low level valid
893 +
894 +1: High level valid
895 +
896 +LED one place: AI1
897 +
898 +LED tens place: AI2
899 +
900 +LED hundreds place: AI3(expend)
901 +)))|0|●|0x0527
902 +|F5.40|Analog input curve selection|(((
903 +One place: AI1
904 +
905 +Tens place: AI2
906 +
907 +Hundreds place: AI3 (expend)
908 +
909 +0: Straight line (default)
910 +
911 +1: Curve 1
912 +
913 +2: Curve 2
914 +)))|0|●|0x0528
915 +|F5.41|Lower limit of curve 1|0.00 to F5.43|0.00V|○|0x0529
916 +|F5.42|The lower limit of curve 1 is set accordingly|0.00 to 100.00%|0.0%|○|0x052A
917 +|F5.43|Curve 1 inflection point 1 Input voltage|F5.41 to F5.45|3.00V|○|0x052B
918 +|F5.44|Curve 1 inflection point 1 corresponds to the setting|0.00 to 100.00%|30.0%|○|0x052C
919 +|F5.45|Curve 1 inflection point 2 Input voltage|F5.43 to F5.47|6.00V|○|0x052D
920 +|F5.46|Curve 1 inflection point 2 corresponds to the setting|0.00 to 100.00%|60.0%|○|0x052E
921 +|F5.47|Upper limit of curve 1|F5.45 to 10.00V|10.0V|○|0x052F
922 +|F5.48|The upper limit of curve 1 is set accordingly|0.00 to 100.00%|100.0%|○|0x0530
923 +|F5.49|Lower limit of curve 2|0.00 to F5.51|0.00V|○|0x0531
924 +|F5.50|The lower limit of curve 2 is set accordingly|0.00 to 100.00%|0.0%|○|0x0532
925 +|F5.51|Curve 2 Inflection point 1 Input voltage|F5.49 to F5.53|3.00V|○|0x0533
926 +|F5.52|Curve 2 inflection point 1 corresponds to the setting|0.00 to 100.00%|30.0%|○|0x0534
927 +|F5.53|Curve 2 Inflection point 2 Input voltage|F5.51 to F5.55|6.00V|○|0x0535
928 +|F5.54|Curve 2 inflection point 2 corresponds to the setting|0.00 to 100.00%|60.0%|○|0x0536
929 +|F5.55|Upper limit of curve 2|F5.53 to 10.00V|10.00V|○|0x0537
930 +|F5.56|The upper limit of curve 2 is set accordingly|0.00 to 100.00%|100.0%|○|0x0538
931 +|F5.57|AI3(Extension) is used to select the DI terminal function|(% rowspan="2" %)(((
932 +0: Non-function
933 +
934 +1: FWD
935 +
936 +2: REV
937 +
938 +3: Three-wire operation control
939 +
940 +4: FJOG
941 +
942 +5: RJOG
943 +
944 +6: Terminal UP
945 +
946 +7: terminal DOWN
947 +
948 +8: Free break
949 +
950 +9: RESET
951 +
952 +10: Running pause
953 +
954 +11: External fault input(NO)
955 +
956 +12: Multi-speed instruction terminal 1
957 +
958 +13: Multi-speed instruction terminal 2
959 +
960 +14: Multi-speed instruction terminal 3
961 +
962 +15: Multi-speed instruction terminal 4
963 +
964 +16: Acceleration and deceleration time select terminal 1
965 +
966 +17: Acceleration and deceleration time select terminal 2
967 +
968 +18: Frequency source switching (terminal, keyboard)
969 +
970 +19: The UP/DOWN setting clears zero
971 +
972 +20: Run the command to switch terminals
973 +
974 +21: Acceleration and deceleration prohibition
975 +
976 +22: PID pause
977 +
978 +23: PLC State reset
979 +
980 +24: Swing pause
981 +
982 +25: Counter input
983 +
984 +26: Counter reset
985 +
986 +27: Length count input
987 +
988 +28: Length reset
989 +
990 +29: Torque control prohibited
991 +
992 +30: PULSE impulse input(only DI4)
993 +
994 +31: Retain
995 +
996 +32: Immediate DC braking
997 +
998 +33: The external fault is normally closed
999 +
1000 +34: Retain
1001 +
1002 +35: The direction of PID action is reversed
1003 +
1004 +36: External parking terminal 1
1005 +
1006 +37: Control command switching terminal
1007 +
1008 +38: PID integration pause terminal
1009 +
1010 +39: Main frequency source and preset frequency switching terminal
1011 +
1012 +40: Auxiliary frequency source and preset frequency switching terminal
1013 +
1014 +41: Retain
1015 +
1016 +42: Retain
1017 +
1018 +43: PID parameter switching terminal
1019 +
1020 +44: User-defined fault 1
1021 +
1022 +45: User-defined fault 2
1023 +
1024 +46: Speed control/torque control switch
1025 +
1026 +47: Emergency stop
1027 +
1028 +48: External parking terminal 2
1029 +
1030 +49: Decelerate DC braking
1031 +
1032 +50: The running time is cleared
1033 +
1034 +51: Timing enable
1035 +
1036 +52: Timing reset
1037 +)))| |○|0x0539
1038 +|F5.58|AI4 (Extension) is used to select the DI terminal function| | |
1039 +|F5.59|(((
1040 +
1041 +
1042 +AI3(Extension) Input selection
1043 +)))|(((
1044 +0: 0 to 10V
1045 +
1046 +1: 4 to 20mA
1047 +
1048 +2: 0 to 20mA
1049 +
1050 +3: 0 to 5V
1051 +
1052 +4: 0.5 to 4.5V
1053 +)))|0| |0x053A
1054 +|F5.60|AI4(Extension) Input selection|(((
1055 +0: 0 to 10V
1056 +
1057 +1: 4 to 20mA
1058 +
1059 +2: 0 to 20mA
1060 +
1061 +3: 0 to 5V
1062 +
1063 +4: 0.5 to 4.5V
1064 +)))|0| |0x053B
1065 +|F5.61|AI3(Extended) lower limit|0 to F5.63|0.00V|○|0x053C
1066 +|F5.62|AI3(Extended) lower limit is set accordingly|-100.0% to +100.0%|0.00%|○|0x053D
1067 +|F5.63|AI3(Extended) Upper limit|F5.61 to +10.00V|10.00V|○|0x053E
1068 +|F5.64|The AI3(Extended) upper limit corresponds to the setting|-100.0% to +100.0%|100.00%|○|0x053F
1069 +|F5.65|AI3(Extended) filtering time|0.00-10.00s|0.10s|○|0x0540
1070 +|F5.71|vX terminal valid state source|(((
1071 +0: Internal connection with virtual vYn
1072 +
1073 +1: Whether the function code setting is valid.
1074 +
1075 +One place: Virtual VDI1
1076 +
1077 +Tens place: Virtual VDI2
1078 +
1079 +Hundred bit: Virtual VDI3
1080 +
1081 +Thousands: Reserved
1082 +)))|0|○|0x0547
1083 +|F5.72|Virtual vX terminal function code set valid status|(((
1084 +0: Invalid;
1085 +
1086 +1: Valid
1087 +
1088 +Units bit: Virtual VDI1
1089 +
1090 +Tens place: Virtual VDI2
1091 +
1092 +Hundreds place: Virtual VDI3
1093 +
1094 +Thousands place: Reserved
1095 +)))|0|○|0x0548
1096 +|F5.73|Select the terminal action mode|(((
1097 +LED one place: free shutdown terminal recovery mode
1098 +
1099 +0: Restore the original command after it is invalid
1100 +
1101 +1: The original instruction is not restored if invalid
1102 +
1103 +LED tens place: emergency stop terminal recovery mode
1104 +
1105 +0: Restore the original command after disconnection
1106 +
1107 +1: The original command is not restored after the disconnect
1108 +
1109 +LED hundreds place: Select terminal operation mode after fault reset
1110 +
1111 +0: The terminal control can be started directly
1112 +
1113 +1: Stop the terminal control before starting
1114 +
1115 +LED thousands place: Reserve
1116 +)))|111|○|0x0549
1117 +|(% colspan="6" %)**F6 Output terminal parameter group**
1118 +|F6.00|FM terminal output selection|(((
1119 +0: Pulse output
1120 +
1121 +1: Open collector output (FMR)
1122 +)))|1|○|0x0600
1123 +|F6.01|FMR open collector output selection|(% rowspan="7" %)(((
1124 +0: No output
1125 +
1126 +1: The inverter is in operation
1127 +
1128 +2: Fault output (Fault shutdown)
1129 +
1130 +3: Frequency level detection FDT1 Output
1131 +
1132 +4: Frequency reaches
1133 +
1134 +5: Zero speed running 1
1135 +
1136 +6: Motor overload forecast alarm
1137 +
1138 +7: Inverter overload forecast alarm
1139 +
1140 +8: Set meter value reached
1141 +
1142 +9: The specified count value is reached
1143 +
1144 +10: Length reached
1145 +
1146 +11: The PLC cycle is complete
1147 +
1148 +12: The accumulated running time reaches
1149 +
1150 +13: Reservations
1151 +
1152 +14: Torque limit
1153 +
1154 +15: Ready to run
1155 +
1156 +16: AI1 > AI2
1157 +
1158 +17: The upper frequency reaches
1159 +
1160 +18: The lower limit frequency reaches 1
1161 +
1162 +19: Output in undervoltage state
1163 +
1164 +20: Communication control
1165 +
1166 +21: Positioning completed (reserved)
1167 +
1168 +22: Positioning close (reserved)
1169 +
1170 +23: Zero speed running 2
1171 +
1172 +24: The cumulative power-on time reaches
1173 +
1174 +25: Frequency level detection FDT2 output
1175 +
1176 +26: Frequency reaches 1 output
1177 +
1178 +27: Frequency reaches 2 output
1179 +
1180 +28: Current reaches 1 output
1181 +
1182 +29: Current reaches 2 output
1183 +
1184 +30: timed to reach output
1185 +
1186 +31: Reserved
1187 +
1188 +32: Reserved
1189 +
1190 +33: Running direction
1191 +
1192 +34: Reserved
1193 +
1194 +35: The module temperature reaches
1195 +
1196 +36: Reserved
1197 +
1198 +37: The lower limit frequency reaches 2
1199 +
1200 +38: Fault output 2
1201 +
1202 +39: Reserved
1203 +
1204 +40: The running time arrives
1205 +
1206 +41: User-defined output 1
1207 +
1208 +42: User-defined output 2
1209 +
1210 +43: Timer output
1211 +
1212 +44: Running forward
1213 +
1214 +45: Reverse running
1215 +)))|0|○|0x0601
1216 +|F6.02|Relay 1 output selection|2|○|0x0602
1217 +|F6.03|Relay 2 output selection (Extended)|0|○|0x0603
1218 +|F6.06|VDO1 output selection|0|●|0x0606
1219 +|F6.07|VDO2 output selection|0|●|0x0607
1220 +|F6.08|VDO3 output selection|0|●|0x0608
1221 +|F6.09|Reserve| |-|0x0609
1222 +|F6.10|AO Output signal selection|(((
1223 +One place: AO1
1224 +
1225 +0: 0 to 10V
1226 +
1227 +1: 4.00 to 20.00mA
1228 +
1229 +2: 0.00 to 20.00mA
1230 +
1231 +Tens place: AO2 (expend)
1232 +
1233 +0: 0 to 10V
1234 +
1235 +1: 4.00 to 20.00mA
1236 +
1237 +2: 0.00 to 20.00mA
1238 +)))|00|-|0x060A
1239 +|F6.11|FMP (Pulse output terminal) output selection|(% rowspan="3" %)(((
1240 +0: Run frequency
1241 +
1242 +1: Setting frequency
1243 +
1244 +2: Output current
1245 +
1246 +3: Output torque
1247 +
1248 +4: Output power
1249 +
1250 +5: Output voltage
1251 +
1252 +6: Reserve
1253 +
1254 +7: AI1
1255 +
1256 +8: AI2
1257 +
1258 +9: AI3(Expansion module)
1259 +
1260 +10: PULSE input value
1261 +
1262 +11: Reserve
1263 +
1264 +12: Communication setting
1265 +
1266 +13: Motor speed
1267 +
1268 +14: Output current (0-1000A, corresponding to 0-10V)
1269 +
1270 +15: Output voltage (0-1000V, corresponding to 0-10V)
1271 +
1272 +16: Bus voltage (0-1000V, corresponding to 0-10V)
1273 +)))|0|○|0x060B
1274 +|F6.12|AO1 Output selection|0|○|0x060C
1275 +|F6.13|AO2 Output(expend)|0|○|0x060D
1276 +|F6.14|FM frequency output upper limit|0.00 to 20.00kHz|20.00kHz|○|0x060E
1277 +|F6.15|AO1 Minimum input|0.00V to F6.17|0.00V|○|0x060F
1278 +|F6.16|AO1 Minimum input corresponds to setting|0.0% to +100.0%|0.0%|○|0x0610
1279 +|F6.17|AO1 Maximum output|F6.15 to +10.00V|10.00V|○|0x0611
1280 +|F6.18|AO1 The maximum output corresponds to the setting|0.0% to +100.0%|100.0%|○|0x0612
1281 +|F6.19|AO2 Minimum output(expend)|0.00V to F6.21|0.00V|○|0x0613
1282 +|F6.20|AO2 Minimum output correspondence settings (expend)|0.0% to +100.0%|0.0%|○|0x0614
1283 +|F6.21|AO2 Maximum output(expend)|F6.19 to +10.00V|10.00V|○|0x0615
1284 +|F6.22|AO2 Maximum output correspondence settings (expend)|0.0% to +100.0%|100.0%|○|0x0616
1285 +|F6.23|FMR connecting delay time|0.0s to 3600.0s|0.0s|○|0x0617
1286 +|F6.24|Relay 1 connecting delay time|0.0 to 3600.0s|0.0s|○|0x0618
1287 +|F6.25|Relay 2 connecting delay time(expend)|0.0s to 3600.0s|0.0s|○|0x0619
1288 +|F6.26|VDO connecting delay time|0.0 to 3600.0s|0.0s|○|0x061A
1289 +|F6.27|FMR disconnect delay time|0.0s to 3600.0s|0.0s|○|0x061B
1290 +|F6.28|Relay 1 disconnect delay time|0.0 to 3600.0s|0.0s|○|0x061C
1291 +|F6.29|Relay 2 disconnect delay time(expend)|0.0s to 3600.0s|0.0s|○|0x061D
1292 +|F6.30|VDO1 disconnect delay|0.0 to 3600.0s|0.0s|○|0x061E
1293 +|F6.31|Output terminal valid status select 1|(((
1294 +0: Positive logic
1295 +
1296 +1: Reverse logic
1297 +
1298 +One place: FDOR
1299 +
1300 +Tens place: RL1
1301 +
1302 +Hundreds place: RL2 (Extended)
1303 +
1304 +Thousands place: -
1305 +)))|000|○|0x061F
1306 +|F6.32|Virtual output terminal valid status Select 2|(((
1307 +0: Positive logic
1308 +
1309 +1: Reverse logic
1310 +
1311 +One place: VDO1
1312 +
1313 +Tens place: VDO2
1314 +
1315 +Hundreds place: VDO3
1316 +
1317 +Thousands palce: -
1318 +)))|000|○|0x0620
1319 +|F6.33|User-defined output selection (EX) 1|(((
1320 +0: The running frequency
1321 +
1322 +1: Set the frequency
1323 +
1324 +2: Bus voltage
1325 +
1326 +3: Output voltage
1327 +
1328 +4: Output current
1329 +
1330 +5: Output power
1331 +
1332 +6: Output torque
1333 +
1334 +7-8: Reserved
1335 +
1336 +9: AI1 input
1337 +
1338 +10: AI2 input
1339 +
1340 +11: AI3 input(expansion module)
1341 +)))|0|○|0x0621
1342 +|F6.34|User selected comparison method 1|(((
1343 +Units: Compare test methods
1344 +
1345 +0: Equal to (EX == X1)
1346 +
1347 +1: The value is greater than or equal to
1348 +
1349 +2: Less than or equal to
1350 +
1351 +3: Interval comparison (X1 ≤ EX ≤ X2)
1352 +
1353 +4: Bit test (EX & X1=X2)
1354 +
1355 +Tens: output mode
1356 +
1357 +0: False value output
1358 +
1359 +1: Truth output
1360 +)))|0|○|0x0622
1361 +|F6.35|User-defined dead zone 1|0 to 65535|0|○|0x0623
1362 +|F6.36|User-defined 1 output comparison value 1|0 to 65535|0|○|0x0624
1363 +|F6.37|User defined 1 output comparison value 2|0 to 65535|0|○|0x0625
1364 +|F6.38|User-defined output selection (EX) 2|(((
1365 +0: The running frequency
1366 +
1367 +1: Set the frequency
1368 +
1369 +2: Bus voltage
1370 +
1371 +3: Output voltage
1372 +
1373 +4: Output current
1374 +
1375 +5: Output power
1376 +
1377 +6: Output torque
1378 +
1379 +7-8: Reserved
1380 +
1381 +9: AI1 input
1382 +
1383 +10: AI2 input
1384 +
1385 +11: AI3 input(Expansion module)
1386 +)))|0|○|0x0626
1387 +|F6.39|User defined comparison method 2|(((
1388 +One place: Compare test methods
1389 +
1390 +0: Equal to (EX == X1)
1391 +
1392 +1: The value is greater than or equal to
1393 +
1394 +2: Less than or equal to
1395 +
1396 +3: Interval comparison (X1 ≤ EX ≤ X2)
1397 +
1398 +4: Bit test (EX & X1=X2)
1399 +
1400 +Tens: output mode
1401 +
1402 +0: False value output
1403 +
1404 +1: Truth output
1405 +)))|0|○|0x0627
1406 +|F6.40|User-defined dead zone 2|0 to 65535|0|○|0x0628
1407 +|F6.41|User defined 2 output comparison value 1|0 to 65535|0|○|0x0629
1408 +|F6.42|User defined 2 output comparison value 2|0 to 65535|0|○|0x062A
1409 +|F6.43|Timer time unit|(((
1410 +0: Second
1411 +
1412 +1: Min
1413 +
1414 +2: Hour
1415 +)))|0|○|0x062B
1416 +|F6.44|Timer maximum|0-65000 (No reset when the set value is 65000)|0|○|0x062C
1417 +|F6.45|Timer set value|0-65000|0|○|0x062D
1418 +|F6.46|Counter maximum|0-65000|0|○|0x062E
1419 +|F6.47|Counter set value|0-65000|0|○|0x062F
1420 +|(% colspan="6" %)**F7 Keyboard and display parameter group**
1421 +|F7.00|LCD Keyboard parameter copy|(((
1422 +0: No operation is performed
1423 +
1424 +1: The function parameters of the machine are uploaded to the LCD keyboard
1425 +
1426 +2: LCD keyboard function parameters download to the machine
1427 +)))|0|○|0x0700
1428 +|F7.01|ENT key function selection|(((
1429 +0: ENT is invalid.
1430 +
1431 +1: Switch between the instruction channel of the operation panel and the remote instruction channel (the remote instruction channel includes communication and terminal control)
1432 +
1433 +2: Reverse switch
1434 +
1435 +3: Forward jog
1436 +
1437 +4: Reverse jog
1438 +
1439 +5: Menu mode switch
1440 +
1441 +6: Reverse operation
1442 +)))|0|●|0x0701
1443 +|F7.02|Keyboard STOP key range|(((
1444 +LED one place: Terminal control selection
1445 +
1446 +0: The terminal instruction is invalid
1447 +
1448 +1: Valid for the terminal command
1449 +
1450 +LED tens place: Communication control selection
1451 +
1452 +0: The communication instruction is invalid.
1453 +
1454 +1: Valid for communication instructions
1455 +
1456 +LED hundreds place: Reserved
1457 +
1458 +LED thousands place: Reserved
1459 +)))|0011|○|0x0702
1460 +|F7.03|Keyboard run displays parameter 1|(((
1461 +LED one place: First group display
1462 +
1463 +0: Output frequency
1464 +
1465 +1: Given frequency
1466 +
1467 +2: Bus voltage
1468 +
1469 +3: Output voltage
1470 +
1471 +4: Output current
1472 +
1473 +5: Output power
1474 +
1475 +6: Output torque
1476 +
1477 +7: DI input status
1478 +
1479 +8: DO output status
1480 +
1481 +9: AI1 voltage
1482 +
1483 +A: AI2 voltage
1484 +
1485 +B: AI3 voltage(expansion module)
1486 +
1487 +C: Reserved
1488 +
1489 +D: Reserved
1490 +
1491 +E: Motor speed
1492 +
1493 +F: PID setting
1494 +
1495 +LED tens place: second group display
1496 +
1497 +LED hundreds place: Third group display
1498 +
1499 +LED thousands place: Fourth group display
1500 +)))|E420|○|0x0703
1501 +|F7.04|Keyboard run displays parameter 2|(((
1502 +LED one place: First group display
1503 +
1504 +0: Not displayed
1505 +
1506 +1: PID feedback
1507 +
1508 +2: PLC stage
1509 +
1510 +3: PULSE input pulse frequency
1511 +
1512 +4: Feedback speed
1513 +
1514 +5: Reserved
1515 +
1516 +6: Reserved
1517 +
1518 +7: Reserved
1519 +
1520 +8: Reserved
1521 +
1522 +9: Current power-on time
1523 +
1524 +A: Current running time
1525 +
1526 +B: Reserved
1527 +
1528 +C: Communication setting
1529 +
1530 +D: Reserved
1531 +
1532 +E: Main frequency X display
1533 +
1534 +F: Auxiliary frequency Y display
1535 +
1536 +LED ten: Second group display
1537 +
1538 +LED hundreds place: Third group display
1539 +
1540 +LED thousands place: Fourth group display
1541 +)))|0000|○|0x0704
1542 +|F7.05|Keyboard stop displays parameters|(((
1543 +LED one place: First group display
1544 +
1545 +0: Output frequency
1546 +
1547 +1: Given frequency
1548 +
1549 +2: Bus voltage
1550 +
1551 +3: Output voltage
1552 +
1553 +4: Output current
1554 +
1555 +5: Output power
1556 +
1557 +6: Output torque
1558 +
1559 +7: DI input status
1560 +
1561 +8: DO output status
1562 +
1563 +9: AI1 voltage
1564 +
1565 +A: AI2 voltage
1566 +
1567 +B:AI3 voltage(Expansion module)
1568 +
1569 +C: Motor speed
1570 +
1571 +D: PID setting
1572 +
1573 +E: PID feedback
1574 +
1575 +F: PLC stage
1576 +
1577 +LED tens place: Second group display
1578 +
1579 +LED hundreds place: Third group display
1580 +
1581 +LED thousands place: Fourth group display
1582 +)))|C421|○|0x0705
1583 +|F7.06|Load speed display factor|0.001 to 65.000|1.000|○|0x0706
1584 +|F7.07|Radiator temperature of inverter module|0℃- 100℃| |◎|0x0707
1585 +|F7.08|Radiator temperature of rectifier bridge|0℃- 100℃| |◎|0x0708
1586 +|F7.09|Cumulative running time|0h to 65535h| |◎|0x0709
1587 +|F7.10|Product number|-| |◎|0x070A
1588 +|F7.11|Software version|-| |◎|0x070B
1589 +|F7.12|Reverse| | |◎|0x070C
1590 +|F7.13|Total power-on time|0 to 65535h| |◎|0x070D
1591 +|F7.14|High cumulative power consumption|(% rowspan="2" %)(((
1592 +Power consumption
1593 +
1594 +~=F7.14*65535+F7.15
1595 +
1596 +Units: kWh
1597 +)))| |◎|0x070E
1598 +|F7.15|Low cumulative power consumption| |◎|0x070F
1599 +|F7.16|Output power correction factor|0 to 100.0%|100.0%|○|0x0710
1600 +|F7.17|Power display dimension selection|(((
1601 +0 to Power display percentage ~(%)
1602 +
1603 +1 to Power display kilowatts (KW)
1604 +)))|1|○|0x0711
1605 +|(% colspan="6" %)F8 Auxiliary function parameter group
1606 +|F8.00|JOG running frequency|0.00Hz -Maximum frequency F0.10|2.00Hz|○|0x0800
1607 +|F8.01|JOG acceleration time|0.00s to 6500.0s|20.0s|○|0x0801
1608 +|F8.02|JOG deceleration time|0.00s to 6500.0s|20.0s|○|0x0802
1609 +|F8.03|Acceleration time 2|0.00s to 6500.0s|(% rowspan="7" %)Model determination|○|0x0803
1610 +|F8.04|Deceleration time 2|0.00s to 6500.0s|○|0x0804
1611 +|F8.05|Acceleration time 3|0.00s to 6500.0s|○|0x0805
1612 +|F8.06|Deceleration time 3|0.00s to 6500.0s|○|0x0806
1613 +|F8.07|Acceleration time 4|0.00s to 6500.0s|○|0x0807
1614 +|F8.08|Deceleration time 4|0.00s to 6500.0s|○|0x0808
1615 +|F8.09|Emergency stop deceleration time|0.00s to 6500.0s|○|0x0809
1616 +|F8.10|Jump frequency 1|0.00Hz -Maximum frequency|0.00Hz|○|0x080A
1617 +|F8.11|Jump frequency 2|0.00Hz -Maximum frequency|0.00Hz|○|0x080B
1618 +|F8.12|Jump frequency amplitude|0.00Hz -Maximum frequency|0.00Hz|○|0x080C
1619 +|F8.13|Forward-reverse dead zone time|0.0 to 120.0s|0.0s|○|0x080D
1620 +|F8.14|The carrier frequency is adjusted with temperature|(((
1621 +0: Temperature independent
1622 +
1623 +1: Temperature dependent
1624 +)))|1|○|0x080E
1625 +|F8.15|Terminal action is preferred|(((
1626 +0: Invalid
1627 +
1628 +1: Valid
1629 +)))|1|○|0x080F
1630 +|F8.16|Setting of accumulated power-on arrive time|0h to 65000h|0h|○|0x0810
1631 +|F8.17|Set the accumulative running arrival time|0h to 65000h|65000h|○|0x0811
1632 +|F8.18|Setting of accumulated power-on arrive action|(((
1633 +0: Continue to run
1634 +
1635 +1: Fault warning
1636 +)))|0|●|0x0812
1637 +|F8.19|Set the accumulative running time arrival action|(((
1638 +0: Continue to run
1639 +
1640 +1: Fault warning
1641 +)))|0|●|0x0813
1642 +|F8.20|Arrival time of this run|0-65000min|0|○|0x0814
1643 +|F8.21|The running time reaches the action selection|(((
1644 +0: Continue to run
1645 +
1646 +1: Fault prompt
1647 +)))|0|●|0x0815
1648 +|F8.22|Frequency detection value(FDT1)|0.00-Maximum frequency|50.00Hz|○|0x0816
1649 +|F8.23|Frequency detection lag value(FDT1)|0.00-Maximum frequency|0.00Hz|○|0x0817
1650 +|F8.24|Frequency detection value(FDT2)|0.00-Maximum frequency|50.00Hz|○|0x0818
1651 +|F8.25|Frequency detection lag value(FDT2)|0.00-Maximum frequency|0.00Hz|○|0x0819
1652 +|F8.26|Frequency reaches the detect width|(((
1653 +0.0% to 100.0%
1654 +
1655 +(Maximum frequency)
1656 +)))|0.0%|○|0x081A
1657 +|F8.27|Arbitrary arrival frequency detection value 1|0.00Hz-Maximum frequency|50.00Hz|○|0x081B
1658 +|F8.28|Arbitrary arrival frequency detection amplitude 1|0.0% to 100.0% (Maximum frequency)|0.0%|○|0x081C
1659 +|F8.29|Arbitrary arrival frequency detection value 2|0.00Hz-Maximum frequency|50.00Hz|○|0x081D
1660 +|F8.30|Arbitrary arrival frequency detection amplitude 1|0.0% to 100.0% (Maximum frequency)|0.0%|○|0x081E
1661 +|F8.31|Arbitrarily reach current1|(((
1662 +0.0% to 300.0%
1663 +
1664 +(Motor rated current)
1665 +)))|100.0%|○|0x081F
1666 +|F8.32|Arbitrarily reach current 1 width|(((
1667 +0.0% to 300.0%
1668 +
1669 +(Motor rated current)
1670 +)))|0.0%|○|0x0820
1671 +|F8.33|Arbitrarily reach current 2|(((
1672 +0.0% to 300.0%
1673 +
1674 +(Motor rated current)
1675 +)))|100.0%|○|0x0821
1676 +|F8.34|Arbitrarily reach current 2 width|(((
1677 +0.0% to 300.0%
1678 +
1679 +(Motor rated current)
1680 +)))|0.0%|○|0x0822
1681 +|F8.35|Zero current detection value|0.0% to 300.0%(Motor rated current)|5.0%|○|0x0823
1682 +|F8.36|Zero current detection delay time|0 to 600.00s|0s|○|0x0824
1683 +|F8.37|Software over current point (D0 output)|(((
1684 +0.0% to 300.0%
1685 +
1686 +(AC drive rated current)
1687 +)))|200.0%|○|0x0825
1688 +|F8.38|Software over current detection delay time|0 to 600.00s|0s|○|0x0826
1689 +|(% colspan="6" %)**F9 Functional parameter array**
1690 +|F9.00|PID setting source|(((
1691 +0: Keyboard number PID given F9.01
1692 +
1693 +1: AI1
1694 +
1695 +2: AI2
1696 +
1697 +3: Reserve
1698 +
1699 +4: Terminal pulse setting
1700 +
1701 +5: Communication setting
1702 +
1703 +6: Multi -stage speed setting
1704 +
1705 +7: Keyboard potentiometer setting
1706 +)))|0|○|0x0900
1707 +|F9.01|PID digital setting|0.0% to 100.0%|50.0%|○|0x0901
1708 +|F9.02|PID feedback source|(((
1709 +0: AI1
1710 +
1711 +1: AI2
1712 +
1713 +2: Reserve
1714 +
1715 +3: AI1-AI2
1716 +
1717 +4: Terminal pulse setting
1718 +
1719 +5: Communication setting
1720 +
1721 +6: AI1+AI2
1722 +
1723 +7: MAX(|AI1|, |AI2|)
1724 +
1725 +8: MIN(|AI1|, |AI2|)
1726 +
1727 +9: Keyboard potentiometer setting
1728 +)))|0|○|0x0902
1729 +|F9.03|PID control characteristics|(((
1730 +LED units: Feedback characteristic selection
1731 +
1732 +0: Positive action
1733 +
1734 +1: Reaction
1735 +
1736 +LED tens: PID adjustment direction selection
1737 +
1738 +0: Reverse prohibition
1739 +
1740 +1: Reverse permit
1741 +
1742 +LED hundreds digit: Alignment selection
1743 +
1744 +0: Off-center alignment
1745 +
1746 +1: Center alignment
1747 +
1748 +LED kilobit: Reserve
1749 +)))|0100|○|0x0903
1750 +|F9.04|PID given feedback range|0 to 65535|1000|○|0x0904
1751 +|F9.05|Proportional gain P1|0 to 1000.0|20.00|○|0x0905
1752 +|F9.06|Integration time I1|0.00s to 10.00s|2.00s|○|0x0906
1753 +|F9.07|Differential time D1|0.00s to 10.00s|0.00s|○|0x0907
1754 +|F9.08|PID reverse cutoff frequency|0.00 to Maximum frequency F0.10|0.00Hz|○|0x0908
1755 +|F9.09|PID deviation limit|0.0% to 100.0%|0.0%|○|0x0909
1756 +|F9.10|PID differential limiting|0.00% to 100.00%|0.10%|○|0x090A
1757 +|F9.11|PID given change time|0.00 to 100.00s|0s|○|0x090B
1758 +|F9.12|PID feedback filtering time|0.00 to 60.00s|0.00s|○|0x090C
1759 +|F9.13|PID output filtering time|0.00 to 60.00s|0.00s|○|0x090D
1760 +|F9.14|Proportional gain P2|0.0 to 1000.0|20.00|○|0x090E
1761 +|F9.15|Integration time I2|0.00s to 10.00s|2.00s|○|0x090F
1762 +|F9.16|Differential time D2|0.00s to 10.00s|0.00s|○|0x0910
1763 +|F9.17|PID parameter switching condition|(((
1764 +0: Do not switch
1765 +
1766 +1: Terminal switching
1767 +
1768 +2: Automatic switching based on deviation
1769 +)))|0|○|0x0911
1770 +|F9.18|PID parameter switching deviation 1|0.0% to F9.19|20.0%|○|0x0912
1771 +|F9.19|PID parameter switching deviation 2|F9.18 to 100.0%|80.0%|○|0x0913
1772 +|F9.20|PID Initial frequency value|0.0% to 100.0%|0%|○|0x0914
1773 +|F9.21|PID Frequency initial holding time|0.0 to 6500.0s|0.0s|○|0x0915
1774 +|F9.23|Feedback wire break action selection|(((
1775 +0: The PID continues to run and no fault is reported
1776 +
1777 +1: Stop and report fault (Manual reset)
1778 +
1779 +2: Continue PID operation, output alarm signal
1780 +
1781 +3: Run at the current frequency, output alarm signal
1782 +
1783 +4: Stop and report fault (Automatic reset)
1784 +)))|0|○|0x0917
1785 +|F9.24|Wire break alarm upper limit|F9.25 to 100.0%|100.0%|○|0x0918
1786 +|F9.25|Line break alarm lower limit|0 to F9.24|0.0%|○|0x0919
1787 +|F9.26|Feedback break detection time|0.0s to 120.0s|0.0s|○|0x091A
1788 +|F9.27|PID stop operation|(((
1789 +0: No operation at stop
1790 +
1791 +1: Operation at stop
1792 +)))|0|○|0x091B
1793 +|F9.28|PID function selection|(((
1794 +0: Normal PID
1795 +
1796 +1: Dormant PID
1797 +)))|0|○|0x091C
1798 +|F9.29|PID sleep threshold|0.0% to 100.0%|60.0%|○|0x091D
1799 +|F9.30|PID sleep delay|0.0 to 3600.0s|3.0s|○|0x091E
1800 +|F9.31|PID wake-up threshold|0.0% to 100.0%|20.0%|○|0x091F
1801 +|F9.32|PID wake up delay|0.0 to 3600.0s|3.0s|○|0x0920
1802 +|F9.33|Dormancy detection frequency|0 to Upper limit frequency F0.12|25.00Hz|○|0x0921
1803 +|F9.34|Minimum output|(((
1804 +0: F0.14(Lower frequency)
1805 +
1806 +1: 0Hz
1807 +)))| |●|0x0922
1808 +|F9.35|Double output deviation reverse minimum|0.00-100.00%|1.00%|○|0x0923
1809 +|F9.36|Double output deviation reverse maximum|0.00-100.00%|1.00%|○|0x0924
1810 +|F9.37|PID integral attribute|(((
1811 +Units place: integral separation
1812 +
1813 +0: Invalid
1814 +
1815 +1: Valid
1816 +
1817 +Tens: output to the limit, whether to stop integrating
1818 +
1819 +0: Continue to integrate
1820 +
1821 +1: Stop collecting points
1822 +)))|0|○|0x0925
1823 +|F9.38|PID Preset Switchover condition selection|(((
1824 +0: Time
1825 +
1826 +1: Switch according to AI1 feedback value
1827 +)))|0|○|0x0926
1828 +|F9.39|PID Minimum value of AI feedback switching|0.0-F9.40|45.0%|○|0x0927
1829 +|F9.40|PID AI feedback maximum switching value|F9.39-100.0%|55.0%|○|0x0928
1830 +|(% colspan="6" %)**FA Fault and protection parameter group**
1831 +|FA.00|Motor overload protection selection|(((
1832 +0: Off
1833 +
1834 +1: On
1835 +)))|1|○|0x0A00
1836 +|FA.01|Motor overload protection factor|0.0-250.0%|100.0%|○|0x0A01
1837 +|FA.02|Motor overload warning coefficient|20.0-250.0%|80.0%|○|0x0A02
1838 +|FA.03|Overvoltage stall and overcurrent stall control selection|(((
1839 +0: Off
1840 +
1841 +1: On
1842 +
1843 +Unit: Excessive suppression enable
1844 +
1845 +Tens: Over current suppression enable
1846 +
1847 +Hundreds: Judge the input of brakes
1848 +
1849 +Thousands: Excessive suppression of fast rising frequency
1850 +)))|1111|○|0x0A03
1851 +|FA.04|Over voltage protection voltage|110% to 150%|Model settings|○|0x0A04
1852 +|FA.05|The Udc controls voltage loop gain|0.00 to 50.00|2.00|○|0x0A05
1853 +|FA.06|The Udc controls current loop gain|0.00 to 50.00|2.00|○|0x0A06
1854 +|FA.07|Overcurrent suppression point|50% to 200%|150%|○|0x0A07
1855 +|FA.08|Overcurrent suppression gain|0.00 to 50.00|2.00|○|0x0A08
1856 +|FA.09|Overcurrent suppression points|0.00 to 50.00|4.00|○|0x0A09
1857 +|FA.10|Short -circuit detection|(((
1858 +0: Invalid
1859 +
1860 +1: Valid
1861 +)))|1|○|0x0A0A
1862 +|FA.11|Input phase loss protection|(((
1863 +0:Disable
1864 +
1865 +1: Enable
1866 +)))|1|○|0x0A0B
1867 +|FA.12|Output phase loss protection|(((
1868 +0:Disable
1869 +
1870 +1: Enable
1871 +)))|1|○|0x0A0C
1872 +|FA.13|Input phase loss protection software detection level|0.0-999.9%|15.0%|○|0x0A0D
1873 +|FA.14|PWM parameter setting|(((
1874 +One place: Enable voltage prediction compensation
1875 +
1876 +Tens - place: PWM update mode
1877 +
1878 +0: Single sample update
1879 +
1880 +1: Double sample and double update
1881 +
1882 +Hundreds place: Random carrier mode
1883 +
1884 +0: Random carrier
1885 +
1886 +1: Random 0 vector
1887 +)))|0010| |0x0A0E
1888 +|FA.15|Hardware current and voltage protection|(((
1889 +One place: Hardware current limit(CBC)
1890 +
1891 +0: Disable
1892 +
1893 +1: Enable
1894 +
1895 +Tens places: -
1896 +
1897 +Hundreds place: FAU filtering time
1898 +
1899 +1 to F
1900 +
1901 +Thousands place: TZ filtering time
1902 +
1903 +1 to F
1904 +)))|0001|○|0x0A0F
1905 +|FA.16|CBC protection point|100-220%|200%|○|0x0A10
1906 +|FA.17|CBC overload protection time|1-5000ms|500ms|○|0x0A11
1907 +|FA.18|Undervoltage threshold setting|40.0% to 100.0%|100.0%|○|0x0A12
1908 +|FA.19|Reserve|-|Model determination|◎|0x0A13
1909 +|FA.20|Number of failure recovery|0 to 5|0|○|0x0A14
1910 +|FA.21|Interval for fault self-recovery|0.1 to 100.0s|1.0s|○|0x0A15
1911 +|FA.22|Power loss ride-through selection|(((
1912 +One place: Power loss ride-through selection function enable
1913 +
1914 +0: Disable
1915 +
1916 +1: Enabled
1917 +
1918 +Tens place: Power loss ride-through function selection
1919 +
1920 +0: Continue to operation
1921 +
1922 +1: Shut down
1923 +)))|0000|○|0x0A16
1924 +|FA.23|Instant stop non-stop enter voltage|40% to 150%|75%|○|0x0A17
1925 +|FA.24|Instant stop non-stop stable voltage|60% to 150%|95%|○|0x0A18
1926 +|(% colspan="6" %)FB Application parameter set
1927 +|FB.00|Swing frequency control|(((
1928 +LED one-place: Swing frequency control
1929 +
1930 +0: The swing frequency control is invalid
1931 +
1932 +1: Swing frequency control is valid
1933 +
1934 +LED tens place: Swing frequency input mode
1935 +
1936 +0: Automatic input
1937 +
1938 +1: Manual input
1939 +
1940 +LED hundreds-place: Swing control
1941 +
1942 +0: Variable swing
1943 +
1944 +1: Fixed swing
1945 +
1946 +LED thousands place: Reserved
1947 +)))|0|●|0x0B00
1948 +|FB.01|Swing preset frequency|0.00-Maximum frequency|0.00Hz|●|0x0B01
1949 +|FB.02|Preset frequency duration|0.00-650.00s|0.00s|●|0x0B02
1950 +|FB.03|Swing amplitude|0.0-100.0%|0.0%|●|0x0B03
1951 +|FB.04|Jump frequency amplitude|0.0-50.0%|0.0%|●|0x0B04
1952 +|FB.05|Swing frequency rise time|0.00-650.00s|5.00s|●|0x0B05
1953 +|FB.06|Swing frequency drop time|0.00-650.00s|5.00s|●|0x0B06
1954 +|(% colspan="6" %)FC Communication parameter group
1955 +|FC.00|Local address|1 to 247, 0 is Broadcast address|1|○|0x0C00
1956 +|FC.01|Baud rate|(((
1957 +0: 300 bps
1958 +
1959 +1: 600 bps
1960 +
1961 +2: 1200 bps
1962 +
1963 +3: 2400 bps
1964 +
1965 +4: 4800 bps
1966 +
1967 +5: 9600 bps
1968 +
1969 +6: 19200 bps
1970 +
1971 +7: 38400 bps
1972 +
1973 +8: 57600 bps
1974 +
1975 +9: 115200 bps
1976 +)))|5|○|0x0C01
1977 +|FC.02|Modbus data format|(((
1978 +0: (8.N.2) 8 data bits, no parity, 2 stop stops
1979 +
1980 +1: (8.E.1) 8 data bits, even parity, 1 stop position
1981 +
1982 +2: (8.O.1) 8 data bits, odd parity, 1 stop stop
1983 +
1984 +3: (8.N.1) 8 data bits, no parity, 1 stop stop
1985 +)))|3|○|0x0C02
1986 +|FC.03|Modbus Communication response delay|0ms to 20ms|2ms|○|0x0C03
1987 +|FC.04|Modbus Communication timeout|0.0 (Invalid), 0.1s to 60.0s|0|○|0x0C04
1988 +|FC.06|​Master-slave selection|(((
1989 +LED units place: Modbus communication master-slave selection
1990 +
1991 +0: Slave 1: Host
1992 +)))|0| |
1993 +|FC.07|Communication ratio setting|0.00 to 5.00|1.00| |
1994 +|FC.08|Modbus communication fault action mode selection|(((
1995 +0: Alarm and free parking (manual reset)
1996 +
1997 +1: No alarm and continue running
1998 +
1999 +2: Alarm and free parking (automatic reset)
2000 +
2001 +3: Parking does not alarm (based on F1.10 parking)
2002 +)))|1| |
2003 +|FC.09|Modbus transfers response processing|(((
2004 +Units place: Write operation response
2005 +
2006 +0: Response to the write operation
2007 +
2008 +1: No response to write operation
2009 +
2010 +Tens Place: Communication exception response​​
2011 +
2012 +0: Response to exception
2013 +
2014 +1: No response to exception
2015 +
2016 +Hundreds place: Communication exception response protocol​
2017 +
2018 +0:8001 1:83
2019 +)))|000| |
2020 +|FC.10|Hosts send selection|(((
2021 +LED units place: 1st group sending frame selection
2022 +
2023 +LED tens place:2st group sending frame selection
2024 +
2025 +LED hunderds place: 3st group sending frame selection
2026 +
2027 +0: Invalid
2028 +
2029 +1: Running command given
2030 +
2031 +2: Host given frequency
2032 +
2033 +3: Host output frequency
2034 +
2035 +4: Host upper limit frequency
2036 +
2037 +6: Host output torque
2038 +
2039 +9: Host given PID A: Host feedback PID
2040 +)))|0x21| |
2041 +|FC.11|RS485 communication port configuration|(((
2042 +0: Configure to Modbus Communication
2043 +
2044 +1: Quota is serial communication
2045 +
2046 +2: UART_OSC
2047 +)))|0| |
2048 +|(% colspan="6" %)**FD Multi -speed instructions and simple PLC parameter arrays**
2049 +|FD.00|Multi-speed instruction 0|-100.0% to 100.0% (100.0% corresponds to maximum frequency F0.10)|0|○|0x0D00
2050 +|FD.01|Multi-speed instruction 1|-100.0% to 100.0%|0|○|0x0D01
2051 +|FD.02|Multi-speed instruction 2|-100.0% to 100.0%|0|○|0x0D02
2052 +|FD.03|Multi-speed instruction 3|-100.0% to 100.0%|0|○|0x0D03
2053 +|FD.04|Multi-speed instruction 4|-100.0% to 100.0%|0|○|0x0D04
2054 +|FD.05|Multi-speed instruction 5|-100.0% to 100.0%|0|○|0x0D05
2055 +|FD.06|Multi-speed instruction 6|-100.0% to 100.0%|0|○|0x0D06
2056 +|FD.07|Multi-speed instruction 7|-100.0% to 100.0%|0|○|0x0D07
2057 +|FD.08|Multi-speed instruction 8|-100.0% to 100.0%|0|○|0x0D08
2058 +|FD.09|Multi -speed instruction 9|-100.0% to 100.0%|0|○|0x0D09
2059 +|FD.10|Multi-speed instruction10|-100.0% to 100.0%|0|○|0x0D0A
2060 +|FD.11|Multi-speed instruction11|-100.0% to 100.0%|0|○|0x0D0B
2061 +|FD.12|Multi-speed instruction12|-100.0% to 100.0%|0|○|0x0D0C
2062 +|FD.13|Multi-speed instruction13|-100.0% to 100.0%|0|○|0x0D0D
2063 +|FD.14|Multi-speed instruction14|-100.0% to 100.0%|0|○|0x0D0E
2064 +|FD.15|Multi-speed instruction15|-100.0% to 100.0%|0|○|0x0D0F
2065 +|FD.16|PLC mode of operation|(((
2066 +0: Stops after a single run
2067 +
2068 +1: Maintain the final value at the end of a single run
2069 +
2070 +2: Keep cycling
2071 +)))|0|○|0x0D10
2072 +|FD.17|PLC Power down memory selection|(((
2073 +Ones Slot:
2074 +
2075 +0: Power failure does not memory
2076 +
2077 +1: Power failure memory
2078 +
2079 +Ten places:
2080 +
2081 +0: Stop and does not remember
2082 +
2083 +1: Shutdown memory
2084 +)))|0|○|0x0D11
2085 +|FD.18|Running time of simple PLC reference 0|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D12
2086 +|FD.19|Acceleration/deceleration time of simple PLC reference 0|0 to 3|0|○|0x0D13
2087 +|FD.20|Running time of simple PLC reference 1|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D14
2088 +|FD.21|Acceleration/deceleration time of simple PLC reference 1|0 to 3|0|○|0x0D15
2089 +|FD.22|Running time of simple PLC reference 2|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D16
2090 +|FD.23|Acceleration/deceleration time of simple PLC reference 2|0 to 3|0|○|0x0D17
2091 +|FD.24|Running time of simple PLC reference 3|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D18
2092 +|FD.25|Acceleration/deceleration time of simple PLC reference 3|0 to 3|0|○|0x0D19
2093 +|FD.26|Running time of simple PLC reference 4|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D1A
2094 +|FD.27|Acceleration/deceleration time of simple PLC reference 4|0 to 3|0|○|0x0D1B
2095 +|FD.28|Running time of simple PLC reference 5|0.0-6553.5(s/m/h)|0.0s(h)|○|0x0D1C
2096 +|FD.29|Acceleration/deceleration time of simple PLC reference 5|0 to 3|0|○|0x0D1D
2097 +|FD.30|Running time of simple PLC reference 6|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D1E
2098 +|FD.31|Acceleration/deceleration time of simple PLC reference 6|0 to 3|0|○|0x0D1F
2099 +|FD.32|Running time of simple PLC reference 7|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D20
2100 +|FD.33|Acceleration/deceleration time of simple PLC reference 6|0 to 3|0|○|0x0D21
2101 +|FD.34|Running time of simple PLC reference 8|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D22
2102 +|FD.35|Acceleration/deceleration time of simple PLC reference 8|0 to 3|0|○|0x0D23
2103 +|FD.36|Running time of simple PLC reference 9|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D24
2104 +|FD.37|Acceleration/deceleration time of simple PLC reference 9|0 to 3|0|○|0x0D25
2105 +|FD.38|Running time of simple PLC reference 10|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D26
2106 +|FD.39|Acceleration/deceleration time of simple PLC reference 10|0 to 3|0|○|0x0D27
2107 +|FD.40|Running time of simple PLC reference 11|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D28
2108 +|FD.41|Acceleration/deceleration time of simple PLC reference 11|0 to 3|0|○|0x0D29
2109 +|FD.42|Running time of simple PLC reference 12|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D2A
2110 +|FD.43|Acceleration/deceleration time of simple PLC reference 12|0 to 3|0|○|0x0D2B
2111 +|FD.44|Running time of simple PLC reference 13|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D2C
2112 +|FD.45|Acceleration/deceleration time of simple PLC reference 13|0 to 3|0|○|0x0D2D
2113 +|FD.46|Running time of simple PLC reference 14|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D2E
2114 +|FD.47|Acceleration/deceleration time of simple PLC reference 14|0 to 3|0|○|0x0D2F
2115 +|FD.48|Running time of simple PLC reference 15|0.0-6553.5 (s/m/h)|0.0s(h)|○|0x0D30
2116 +|FD.49|Acceleration/deceleration time of simple PLC reference 15|0 to 3|0|○|0x0D31
2117 +|FD.50|PLC Run-time unit|(((
2118 +LED units: timing unit
2119 +
2120 +0: s(seconds)
2121 +
2122 +1: h(hours)
2123 +
2124 +2: min(minutes)
2125 +)))|0|○|0x0D32
2126 +|FD.51|Multi-segment speed instruction 0 given mode|(((
2127 +0: Function code FD.00 is given
2128 +
2129 +1: AI1
2130 +
2131 +2: AI2
2132 +
2133 +3: AI3 (expansion)
2134 +
2135 +4: Terminal pulse PULSE given
2136 +
2137 +5: PID
2138 +
2139 +6: Preset frequency (F0.08) given, UP/DOWN modifiable
2140 +
2141 +7: Keyboard potentiometer given
2142 +)))|0|○|0x0D33
2143 +|FD.52|Multispeed priority|(((
2144 +0: Invalid
2145 +
2146 +1: Valid
2147 +)))|1|○|0x0D34
2148 +|(% colspan="6" %)**FE User parameter group**
2149 +|FE.00|User password|0 to 65535|0|○|0x0E00
2150 +|FE.01|Fault record display times|0 to 8|4|○|0x0E01
2151 +|FE.02|Parameter and key lock selection|(((
2152 +0: Not locked
2153 +
2154 +1: The function parameter is locked
2155 +)))|0|○|0x0E02
2156 +|(% colspan="6" %)**A0 Application parameter group**
2157 +|A0.00|Application macro|(((
2158 +0:Default macro
2159 +
2160 +1: Pressure machine macro
2161 +
2162 +2: Spring machinery macro
2163 +
2164 +3: woodworking machinery macro
2165 +)))|0|●|0xA000
2166 +|(% colspan="6" %)**A4 Constant pressure water supply parameter group**
2167 +|A4.00|Water supply function selection|(((
2168 +0: Invalid
2169 +
2170 +1: Valid
2171 +)))|0|●|0xA400
2172 +|A4.01|Setting pressure|1.0 to A4.19|3.0bar|○|0xA401
2173 +|A4.02|Starting pressure|0.0 to A4.01|0.3bar|○|0xA402
2174 +|A4.03|Sensor range|1.0 to 200.0bar|16.0bar|○|0xA403
2175 +|A4.04|Sensor feedback type|(((
2176 +0: 4 to 20mA(AI2)
2177 +
2178 +1: 0 to 10V(AI1)
2179 +)))|0|○|0xA404
2180 +|A4.05|Pressure calibration factor|0.750 to 1.250|1.000|○|0xA405
2181 +|A4.06|Proportional gain P|0.0 to 100.0|50.0|○|0xA406
2182 +|A4.07|Integration time I|0.00s to 10.00s|0.50|○|0xA407
2183 +|A4.08|Differential time|0.000s to 10.000s|0.000|○|0xA408
2184 +|A4.09|Sleep time|(((
2185 +0: Disable
2186 +
2187 +1: Sleep mode 1
2188 +
2189 +2: Sleep mode 2
2190 +)))|(((
2191 +
2192 +
2193 +1
2194 +)))|○|(((
2195 +
2196 +
2197 +0xA409
2198 +)))
2199 +|A4.10|Sleep delay|0.0s to 100.0s|5.0s|○|0xA40A
2200 +|A4.11|Wake up delay|0.0s to 100.0s|3.0|○|0xA40B
2201 +|A4.12|Low-frequency hold frequency|0.0 to A4.14|20.00Hz|○|0xA40C
2202 +|A4.13|Low frequency hold frequency running time|0.0s to 100.0s|5.0s|○|0xA40D
2203 +|A4.14|Sleep frequency|A4.12 to F0.12|25.00Hz|○|0xA40E
2204 +|A4.15|Sleep detection cycle|0.0s to 600.0s|30.0s|○|0xA40F
2205 +|A4.16|Leaking coefficient|0.1s to 100.0s|2.5s|○|0xA410
2206 +|A4.17|Sleep detection coefficient|1 to 10|4|○|0xA411
2207 +|A4.18|Deadband pressure|0.0bar to 1.0bar|0.1bar|○|0xA412
2208 +|A4.19| High voltage alarm setting value|A4.00 to A4.03|15.0bar|○|0xA413
2209 +|A4.20| Low voltage alarm setting value|0.0 to A4.01|0.0bar|○|0xA414
2210 +|A4.21|Water pressure alarm delay time|0.0 to 100.0|3.0s|○|0xA415
2211 +|A4.22|Sensor disconnection detection value|0.00 to 10.00V|0.20|○|0xA416
2212 +|A4.23|Sensor disconnection detection time|0.0s to 100.0s|30.0s|○|0xA417
2213 +|A4.24|Water shortage protection function|(((
2214 +0: Disable
2215 +
2216 +1: Judging by frequency and current
2217 +
2218 +2: Judging by frequency and pressure
2219 +)))|2|○|0xA418
2220 +|A4.25|Water shortage fault detection threshold|0.00s to 10.00s|0.50|○|0xA419
2221 +|A4.26|Water shortage protection detection frequency|0 to F0.12|48.00Hz|○|0xA41A
2222 +|A4.27|Water shortage protection detection current percentage|0.0 to 100.0%|40.0%|○|0xA41B
2223 +|A4.28|Water shortage protection detection time|0.0 to 200.0s|60.0s|○|0xA41C
2224 +|A4.29|Water shortage protection automatic reset delay|0 to 1000|15|○|0xA41D
2225 +|A4.30|Number of Auto-resets for water shortage protection|0 to 100|10|○|0xA41E
2226 +|A4.31|Pressure rise control function|(((
2227 +0: Invalid
2228 +
2229 +1: Valid
2230 +)))|0|○|0xA41F
2231 +|(((
2232 +
2233 +
2234 +A4.35
2235 +)))|Constant frequency water shortage function selection|(((
2236 +One place: Turn on protection
2237 +
2238 +0: Disable 1: Enable
2239 +
2240 +Tens place: Current detected
2241 +
2242 +0: Total current 1: Torque current
2243 +)))|(((
2244 +
2245 +
2246 +0010
2247 +)))| |
2248 +|A4.36|Constant frequency water shortage protection current|0% to 150%|40%| |
2249 +|A4.37|Constant frequency water shortage protection frequency|0% to 100%|50%| |
2250 +|A4.38|Constant frequency water shortage protection detection time|1 to 1000s|30s| |
2251 +|A4.39|Constant frequency water shortage protection recovery time|1 to 10000s|600s| |
2252 +|A4.40| Constant frequency water shortage protection recovery times|0 to 100|3| |
2253 +
2254 +
2255 +
2256 +6.2 Fault record parameter group
2257 +
2258 +|**Function code**|**Name**|**Setting range and description**|**Change**|(((
2259 +**Modbus**
2260 +
2261 +**address**
2262 +)))
2263 +|(% colspan="5" %)**E0 Fault parameter set**
2264 +|E0.00|Fault type|Refer to the fault Information code table for detail|◎|0xE000
2265 +|E0.01|Failure operating frequency|0.0-Maximum frequency|◎|0xE001
2266 +|E0.02|Fault output current|0.1-2000.0A|◎|0xE002
2267 +|E0.03|Fault bus voltage|0-810.0V|◎|0xE003
2268 +|E0.04|Fault input terminal status|Refer to the input terminal state diagram|◎|0xE004
2269 +|E0.05|Fault output terminal status|Refer to the output terminal state diagram|◎|0xE005
2270 +|E0.06|Fault module temperature|0-100℃|◎|0xE006
2271 +|E0.07|Fault VFD condition|(((
2272 +LED one place: Running direction
2273 +
2274 +0: Forward
2275 +
2276 +1: Reverse
2277 +
2278 +LED tens place: Running status
2279 +
2280 +0: Stop
2281 +
2282 +1: Steady speed
2283 +
2284 +2: Speed up
2285 +
2286 +3: Slow down
2287 +)))|◎|0xE007
2288 +|E0.08|(((
2289 +Down time
2290 +
2291 +(Count from this power-on)
2292 +)))|0-65535min|◎|0xE008
2293 +|E0.09|(((
2294 +Down time
2295 +
2296 +(From total running time)
2297 +)))|0-65535H|◎|0xE009
2298 +|E0.10|Fault output voltage|0-1500V|◎|0xE00A
2299 +|E0.11|Fault diagnosis information|Refer to (Chapter 8 to Fault Code Details)|◎|0xE00B
2300 +|E0.12|Number of faulty CBC|10Sec if no CBC zeroing|◎|0xE00C
2301 +
2302 +6.3 Display parameter group
2303 +
2304 +|**Function code**|**Name**|**Minimum unit**|**Change**|**Modbus address**
2305 +|(% colspan="5" %)**D0 Display parameter group**
2306 +|D0.00|Running frequency(Hz)|0.01Hz|◎|0xD000
2307 +|D0.01|Setting frequency(Hz)|0.01Hz|◎|0xD001
2308 +|D0.02|Bus voltage(V)|0.1V|◎|0xD002
2309 +|D0.03|Output voltage(V)|1V|◎|0xD003
2310 +|D0.04|Output current(A)|0.1A|◎|0xD004
2311 +|D0.05|Output power(kW)|0.1kW|◎|0xD005
2312 +|D0.06|Output torque~(%)|0.1%|◎|0xD006
2313 +|D0.07|DI Input state| |◎|0xD007
2314 +|D0.08|DO Output state| |◎|0xD008
2315 +|D0.09|AI1 Voltage (V)|0.01V|◎|0xD009
2316 +|D0.10|AI2 Voltage(V)|0.01V|◎|0xD00A
2317 +|D0.11|AO1 Voltage(V)|0.01V|◎|0xD00B
2318 +|D0.12|Count value| |◎|0xD00C
2319 +|D0.13|Axis Frequency| |◎|0xD00D
2320 +|D0.14|Load speed display|1rpm|◎|0xD00E
2321 +|D0.15|PID setting| |◎|0xD00F
2322 +|D0.16|PID feedback| |◎|0xD010
2323 +|D0.17|PLC phase| |◎|0xD011
2324 +|D0.18|PULSE input pulse frequency| |◎|0xD012
2325 +|D0.19|Feedback speed(Unit0.1Hz)| |◎|0xD013
2326 +|D0.20|Remaining running time| |◎|0xD014
2327 +|D0.21|AI1Pre-correction voltage| |◎|0xD015
2328 +|D0.22|AI2Pre-correction voltage| |◎|0xD016
2329 +|D0.23|Reserve| |◎|0xD017
2330 +|D0.24|Linear velocity| |◎|0xD018
2331 +|D0.25|Current power-on time|1min|◎|0xD019
2332 +|D0.26|Current running time|0.1min|◎|0xD01A
2333 +|D0.27|CPU temperature| |◎|0xD01B
2334 +|D0.28|Communication setting| |◎|0xD01C
2335 +|D0.29|Radiator temperature| |◎|0xD01D
2336 +|D0.30|Main frequency X display|0.01Hz|◎|0xD01E
2337 +|D0.31|Auxiliary frequency Y display|0.01Hz|◎|0xD01F
2338 +|D0.34|Reserve| |◎|0xD022
2339 +|D0.35|Analog grounding| |◎|0xD023
2340 +|D0.36|3.3VA| |◎|0xD024
2341 +|D0.37|Control board plate number| |◎|0xD025
2342 +|D0.38|Plate number of the power board| |◎|0xD026
2343 +|D0.39|Power factor Angle| |◎|0xD027
2344 +|D0.40|Virtual VDI state| |◎|0xD100
2345 +|D0.41|Virtual VDO state| |◎|0xD101
2346 +|D0.42|Expand DI input status| |◎|0xD102
2347 +|D0.43|Expand DO input status| |◎|0xD103
2348 +|D0.44|Expansion board version| |◎|0xD104
2349 +|D0.45|AI3 (Expand) voltage (V)|0.01V|◎|0xD105
2350 +|D0.46|AI4 (Expand) voltage (V)|0.01V|◎|0xD106
2351 +|D0.49|AO2 Voltage (V)|0.01V|◎|0xD109
2352 +|D0.53|Communication status of the main control board| |◎|0xD10D
2353 +|D0.54|Extended communication status| |◎|0xD10E
2354 +
2355 +
2356 +
2357 +
2358 +6.4 A0 Application parameter group
2359 +
2360 +Notes: As the software iterates, the parameter list may change.
2361 +
2362 +|**Function code**|**Name**|**Minimum unit**|**Change**|(((
2363 +**Modbus**
2364 +
2365 +**address**
2366 +)))
2367 +|(% colspan="5" %)**A0 Application parameter set**
2368 +|A0.00|Application macro|(((
2369 +0: Default macro
2370 +
2371 +1: Pressure tile machinery macro
2372 +
2373 +2: Spring machinery macro
2374 +
2375 +3: Woodworking machinery macro
2376 +)))|●|0xA000