Changes for page 1 VM Series Manual V1.2
Last modified by Mora Zhou on 2023/12/28 10:44
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - WECONVM AC DriveUserManual1 +1 VM AC Drive Manual - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - 2\.User Manual.WebHome1 +VFD.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.Stone - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= Preface = 1 += 1 Preface = 2 2 3 3 Thank you for choosing WECON VM Series AC Drive. 4 4 ... ... @@ -9,7 +9,7 @@ 9 9 Be sure to verify that the wiring is correct before powering on the product. Before starting the product, it is necessary to debug to ensure correct motor rotating direction. 10 10 11 11 12 -= Safety precautions = 12 += 2 Safety precautions = 13 13 14 14 **■ Warning sign** 15 15 ... ... @@ -17,7 +17,7 @@ 17 17 18 18 [[image:WECON VM 英文 V01_html_b36792972403c101.png]] WARNING: Indicates that failure to comply with the notice will result in moderate personal injury, property damage or equipment damage. 19 19 20 -|**WARNING** 20 +(% class="warning" %)|**WARNING** 21 21 |((( 22 22 ◎Do not install or operate any AC Drive that is damaged or with missing parts. Failing to follow this rule can result in facility damage or severe injury. 23 23 ... ... @@ -48,7 +48,7 @@ 48 48 ◎The PCB board has a CMOS integrated circuit. Do not touch it with your hands, otherwise, static electricity will damage the PCB board. 49 49 ))) 50 50 51 -|**DANGER** 51 +(% class="warning" %)|**DANGER** 52 52 |((( 53 53 ◎Wiring must be completed by qualified professional electricians, otherwise, there may be electric shock or damage to the AC Drive. 54 54 ... ... @@ -77,11 +77,11 @@ 77 77 ◎Modification to the AC Drive without permission is strictly prohibited, otherwise, severe injury may be caused. Arbitrarily modification of AC Drive will result in service warranty invalid. 78 78 ))) 79 79 80 -= Chapter1Product information =80 += 3 Product information = 81 81 82 -== 1.1Technical specifications ==82 +== Technical specifications == 83 83 84 -|(% colspan="2" %)**Item**|**Specifications** 84 +|=(% colspan="2" %)**Item**|=**Specifications** 85 85 |(% rowspan="7" %)Control features|Control mode|V/F control 86 86 |Startup torque|0.5Hz/100% 87 87 |Speed range|1:50 ... ... @@ -113,13 +113,13 @@ 113 113 114 114 Table 1-1-1 Technical specification shee 115 115 116 -== 1.2Product nameplate ==116 +== Product nameplate == 117 117 118 118 [[image:WECON VM 英文 V01_html_5a52ff18546c8417.png]] 119 119 120 120 Figure 1-2-1 Product nameplate 121 121 122 -== 1.3Model description ==122 +== Model description == 123 123 124 124 __VM__ – __2__ __S__ __1R5GB__ 125 125 ... ... @@ -133,7 +133,7 @@ 133 133 134 134 Table 1-3-1 VM series model field comment 135 135 136 -== 1.4Product model ==136 +== Product model == 137 137 138 138 |(% rowspan="2" %)AC Drive Model|Rated power|Power capacity|Input current|Output current|(% colspan="2" %)Motor G/P 139 139 |kW|kVA|A|A|kW|HP ... ... @@ -151,10 +151,12 @@ 151 151 152 152 *:In development 153 153 154 += 4 Installation = 154 154 155 -= Chapter2 Installation =156 +== Overall structural drawing == 156 156 157 -== 2.1 Overall structural drawing(unit:mm) == 158 +(% class="wikigeneratedid" %) 159 +unit: mm 158 158 159 159 [[image:1624240220324-243.png]] 160 160 ... ... @@ -174,21 +174,14 @@ 174 174 175 175 Table 2-1-1 outline dimension 176 176 177 -== 2.2Terminal connection ==179 +== Terminal connection == 178 178 179 - 180 180 [[image:1624240272484-903.png]] 181 181 182 182 Figure 2-2-1 Terminal connection 183 183 185 +**Main circuit connection** 184 184 185 - 186 - 187 - 188 - 189 - 190 -* **Main circuit connection** 191 - 192 192 |**Terminal mark**|**Name**|**Description** 193 193 |R、S、T|Power supply input terminals|Connect to the AC power supply 194 194 |U、V、W|AC drive output terminals|Connect the three-phase motor. ... ... @@ -196,7 +196,7 @@ 196 196 197 197 Table 2-2-1 Main circuit terminals and function 198 198 199 -* *Control circuit connection**194 +**Control circuit connection** 200 200 201 201 |**Category**|**Terminal symbol**|**Terminal name**|**Function description** 202 202 |(% rowspan="2" %)Power supply|+10V-GND|+10V power supply|((( ... ... @@ -216,9 +216,9 @@ 216 216 217 217 Table 2-2-2 Control terminal instruction 218 218 219 -= Chapter3Display and operation =214 += 5 Display and operation = 220 220 221 -== 3.1Keypad ==216 +== Keypad == 222 222 223 223 You can modify the parameters, monitor the working status and start or stop the AC Drive by operating the keypad, as shown in the following figure. 224 224 ... ... @@ -226,7 +226,7 @@ 226 226 227 227 Figure 3-1-1 Keypad diagram 228 228 229 -== 3.2Description of indicators and keys ==224 +== Description of indicators and keys == 230 230 231 231 |**Item**|**Name**|**Function** 232 232 |Indicator|Status|((( ... ... @@ -253,9 +253,8 @@ 253 253 254 254 Table 3-2-1 Description of Indicators and key 255 255 251 += 6 Parameter function = 256 256 257 -= Chapter 4 Parameter function = 258 - 259 259 “○”: the parameter can be modified in both standby and operating state; 260 260 261 261 “●”: the parameter can’t be modified in operating state; ... ... @@ -264,9 +264,8 @@ 264 264 265 265 Note: the communication address is hexadecimal. 266 266 261 +== Functional parameter == 267 267 268 -== 4.1 Functional parameter == 269 - 270 270 |Parameter|Name|Setting Range|Default|Property|Address 271 271 |F0.00|Reserved|Reserved|0|●|0000 272 272 |F0.01|Command source selection|0:Operation panel control(LED off) ... ... @@ -528,7 +528,7 @@ 528 528 1:AI 529 529 )))|0|○|0D0F 530 530 531 -== 4.2Monitoring Parameters ==524 +== Monitoring Parameters == 532 532 533 533 |Parameter|Name|Minimum Unit|Priority|Address 534 534 |D0.00|Running Frequency(Hz)|0.01Hz|◎|D000 ... ... @@ -545,7 +545,7 @@ 545 545 |D0.13|PLC Stage|1|◎|D013 546 546 |D0.14|Feedback Speed(Unit0.1Hz)|0.1Hz|◎|D014 547 547 548 -== 4.3Error Records ==541 +== Error Records == 549 549 550 550 |Parameter|Name|Range and Description|Priority|Address 551 551 |E0.00|Latest error type|No Error:0 ... ... @@ -575,11 +575,11 @@ 575 575 |E1.04|Input terminals status at former error|0-63|●| E104 576 576 |E1.05|IGBT temperature at former error|0-65535|●| E105 577 577 578 -= Chapter5Communication Protocol =571 += 7 Communication Protocol = 579 579 580 580 VM Series AC Drive provides RS485 communication interface and supports Modbus communication protocol. Users can achieve centralized control by computer or PLC, set AC Drive operation commands, modify or read function code parameters, read the working state and fault info of the AC Drive. 581 581 582 -== 5.1Communication Control Address ==575 +== Communication Control Address == 583 583 584 584 |Function|Address|Description|Remarks|Characteristic 585 585 |Communication Set Value|1000H|-10000~10000(with ± sign)|F0.05*(±100.00%)|R/W ... ... @@ -630,7 +630,7 @@ 630 630 631 631 Sheet 5-1-1 Control Command Addresses 632 632 633 -== 5.2EEPROM Addresses Introduction ==626 +== EEPROM Addresses Introduction == 634 634 635 635 The addresses listed in the sheet above is the way of writing RAM. The RAM stores the data after power-off and does not save it. In the communication mode, for the write command "06H", if the parameter needs to be stored after power-off, the method of writing EEPROM should be used. The original "0" of the most significant bit of the RAM address is changed to "F", which is converted into the corresponding EEPROM address, for example: "0XXX" is changed to "FXXX" 636 636 ... ... @@ -642,9 +642,9 @@ 642 642 643 643 It should be noted that the erasing life of EEPROM is about 1 million times. After exceeding the erasing times, it will affect the reliability of data storage. If it is not necessary, it is recommended to control the communication by writing to RAM. 644 644 645 -= Chapter6Troubleshooting & countermeasures =638 += 9 Troubleshooting & countermeasures = 646 646 647 -== 6.1Faults and solutions ==640 +== Faults and solutions == 648 648 649 649 |Fault code|Fault type|Reason|Solution 650 650 |Err02|Overcurrent during acceleration|((( ... ... @@ -797,9 +797,8 @@ 797 797 798 798 Table 6-1-1 Faults and solutions 799 799 793 +== Common faults and solutions == 800 800 801 -== 6.2 Common faults and solutions == 802 - 803 803 |**SN**|**Fault**|**Possible causes**|**Solutions** 804 804 |1|No display at power-on state|((( 805 805 ~1. The input power of AC Drive is abnormal.