Changes for page 1 VM Series Manual V1.2

Last modified by Mora Zhou on 2023/12/28 10:44

From version 2.1
edited by Leo Wei
on 2022/06/08 14:52
Change comment: Renamed from xwiki:2\. User Manual.WECON VM AC Drive User Manual.WebHome
To version 5.1
edited by Stone Wu
on 2022/08/01 14:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -WECON VM AC Drive User Manual
1 +1 VM AC Drive Manual
Parent
... ... @@ -1,1 +1,1 @@
1 -2\. User Manual.WebHome
1 +VFD.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.Stone
Content
... ... @@ -1,4 +1,4 @@
1 -= Preface =
1 += 1 Preface =
2 2  
3 3  Thank you for choosing WECON VM Series AC Drive.
4 4  
... ... @@ -9,7 +9,7 @@
9 9  Be sure to verify that the wiring is correct before powering on the product. Before starting the product, it is necessary to debug to ensure correct motor rotating direction.
10 10  
11 11  
12 -= Safety precautions =
12 += 2 Safety precautions =
13 13  
14 14  **■ Warning sign**
15 15  
... ... @@ -17,7 +17,7 @@
17 17  
18 18  [[image:WECON VM 英文 V01_html_b36792972403c101.png]] WARNING: Indicates that failure to comply with the notice will result in moderate personal injury, property damage or equipment damage.
19 19  
20 -|**WARNING**
20 +(% class="warning" %)|**WARNING**
21 21  |(((
22 22  ◎Do not install or operate any AC Drive that is damaged or with missing parts. Failing to follow this rule can result in facility damage or severe injury.
23 23  
... ... @@ -48,7 +48,7 @@
48 48  ◎The PCB board has a CMOS integrated circuit. Do not touch it with your hands, otherwise, static electricity will damage the PCB board.
49 49  )))
50 50  
51 -|**DANGER**
51 +(% class="warning" %)|**DANGER**
52 52  |(((
53 53  ◎Wiring must be completed by qualified professional electricians, otherwise, there may be electric shock or damage to the AC Drive.
54 54  
... ... @@ -77,11 +77,11 @@
77 77  ◎Modification to the AC Drive without permission is strictly prohibited, otherwise, severe injury may be caused. Arbitrarily modification of AC Drive will result in service warranty invalid.
78 78  )))
79 79  
80 -= Chapter 1 Product information =
80 += 3 Product information =
81 81  
82 -== 1.1 Technical specifications ==
82 +== Technical specifications ==
83 83  
84 -|(% colspan="2" %)**Item**|**Specifications**
84 +|=(% colspan="2" %)**Item**|=**Specifications**
85 85  |(% rowspan="7" %)Control features|Control mode|V/F control
86 86  |Startup torque|0.5Hz/100%
87 87  |Speed range|1:50
... ... @@ -113,13 +113,13 @@
113 113  
114 114  Table 1-1-1 Technical specification shee
115 115  
116 -== 1.2 Product nameplate ==
116 +== Product nameplate ==
117 117  
118 118  [[image:WECON VM 英文 V01_html_5a52ff18546c8417.png]]
119 119  
120 120  Figure 1-2-1 Product nameplate
121 121  
122 -== 1.3 Model description ==
122 +== Model description ==
123 123  
124 124  __VM__ – __2__ __S__ __1R5GB__
125 125  
... ... @@ -133,7 +133,7 @@
133 133  
134 134  Table 1-3-1 VM series model field comment
135 135  
136 -== 1.4 Product model ==
136 +== Product model ==
137 137  
138 138  |(% rowspan="2" %)AC Drive Model|Rated power|Power capacity|Input current|Output current|(% colspan="2" %)Motor G/P
139 139  |kW|kVA|A|A|kW|HP
... ... @@ -151,10 +151,12 @@
151 151  
152 152  *:In development
153 153  
154 += 4 Installation =
154 154  
155 -= Chapter 2 Installation =
156 +== Overall structural drawing ==
156 156  
157 -== 2.1 Overall structural drawing(unit:mm) ==
158 +(% class="wikigeneratedid" %)
159 +unit: mm
158 158  
159 159  [[image:1624240220324-243.png]]
160 160  
... ... @@ -174,21 +174,14 @@
174 174  
175 175  Table 2-1-1 outline dimension
176 176  
177 -== 2.2 Terminal connection ==
179 +== Terminal connection ==
178 178  
179 -
180 180  [[image:1624240272484-903.png]]
181 181  
182 182  Figure 2-2-1 Terminal connection
183 183  
185 +**Main circuit connection**
184 184  
185 -
186 -
187 -
188 -
189 -
190 -* **Main circuit connection**
191 -
192 192  |**Terminal mark**|**Name**|**Description**
193 193  |R、S、T|Power supply input terminals|Connect to the AC power supply
194 194  |U、V、W|AC drive output terminals|Connect the three-phase motor.
... ... @@ -196,7 +196,7 @@
196 196  
197 197  Table 2-2-1 Main circuit terminals and function
198 198  
199 -* **Control circuit connection**
194 +**Control circuit connection**
200 200  
201 201  |**Category**|**Terminal symbol**|**Terminal name**|**Function description**
202 202  |(% rowspan="2" %)Power supply|+10V-GND|+10V power supply|(((
... ... @@ -216,9 +216,9 @@
216 216  
217 217  Table 2-2-2 Control terminal instruction
218 218  
219 -= Chapter 3 Display and operation =
214 += 5 Display and operation =
220 220  
221 -== 3.1 Keypad ==
216 +== Keypad ==
222 222  
223 223  You can modify the parameters, monitor the working status and start or stop the AC Drive by operating the keypad, as shown in the following figure.
224 224  
... ... @@ -226,7 +226,7 @@
226 226  
227 227  Figure 3-1-1 Keypad diagram
228 228  
229 -== 3.2 Description of indicators and keys ==
224 +== Description of indicators and keys ==
230 230  
231 231  |**Item**|**Name**|**Function**
232 232  |Indicator|Status|(((
... ... @@ -253,9 +253,8 @@
253 253  
254 254  Table 3-2-1 Description of Indicators and key
255 255  
251 += 6 Parameter function =
256 256  
257 -= Chapter 4 Parameter function =
258 -
259 259  “○”: the parameter can be modified in both standby and operating state;
260 260  
261 261  “●”: the parameter can’t be modified in operating state;
... ... @@ -264,9 +264,8 @@
264 264  
265 265  Note: the communication address is hexadecimal.
266 266  
261 +== Functional parameter ==
267 267  
268 -== 4.1 Functional parameter ==
269 -
270 270  |Parameter|Name|Setting Range|Default|Property|Address
271 271  |F0.00|Reserved|Reserved|0|●|0000
272 272  |F0.01|Command source selection|0:Operation panel control(LED off)
... ... @@ -528,7 +528,7 @@
528 528  1:AI
529 529  )))|0|○|0D0F
530 530  
531 -== 4.2 Monitoring Parameters ==
524 +== Monitoring Parameters ==
532 532  
533 533  |Parameter|Name|Minimum Unit|Priority|Address
534 534  |D0.00|Running Frequency(Hz)|0.01Hz|◎|D000
... ... @@ -545,7 +545,7 @@
545 545  |D0.13|PLC Stage|1|◎|D013
546 546  |D0.14|Feedback Speed(Unit0.1Hz)|0.1Hz|◎|D014
547 547  
548 -== 4.3 Error Records ==
541 +== Error Records ==
549 549  
550 550  |Parameter|Name|Range and Description|Priority|Address
551 551  |E0.00|Latest error type|No Error:0
... ... @@ -575,11 +575,11 @@
575 575  |E1.04|Input terminals status at former error|0-63|●| E104
576 576  |E1.05|IGBT temperature at former error|0-65535|●| E105
577 577  
578 -= Chapter5 Communication Protocol =
571 += 8 Communication Protocol =
579 579  
580 580  VM Series AC Drive provides RS485 communication interface and supports Modbus communication protocol. Users can achieve centralized control by computer or PLC, set AC Drive operation commands, modify or read function code parameters, read the working state and fault info of the AC Drive.
581 581  
582 -== 5.1 Communication Control Address ==
575 +== Communication Control Address ==
583 583  
584 584  |Function|Address|Description|Remarks|Characteristic
585 585  |Communication Set Value|1000H|-10000~10000(with ± sign)|F0.05*(±100.00%)|R/W
... ... @@ -630,7 +630,7 @@
630 630  
631 631  Sheet 5-1-1 Control Command Addresses
632 632  
633 -== 5.2 EEPROM Addresses Introduction ==
626 +== EEPROM Addresses Introduction ==
634 634  
635 635  The addresses listed in the sheet above is the way of writing RAM. The RAM stores the data after power-off and does not save it. In the communication mode, for the write command "06H", if the parameter needs to be stored after power-off, the method of writing EEPROM should be used. The original "0" of the most significant bit of the RAM address is changed to "F", which is converted into the corresponding EEPROM address, for example: "0XXX" is changed to "FXXX"
636 636  
... ... @@ -642,9 +642,9 @@
642 642  
643 643  It should be noted that the erasing life of EEPROM is about 1 million times. After exceeding the erasing times, it will affect the reliability of data storage. If it is not necessary, it is recommended to control the communication by writing to RAM.
644 644  
645 -= Chapter 6 Troubleshooting & countermeasures =
638 += 9 Troubleshooting & countermeasures =
646 646  
647 -== 6.1 Faults and solutions ==
640 +== Faults and solutions ==
648 648  
649 649  |Fault code|Fault type|Reason|Solution
650 650  |Err02|Overcurrent during acceleration|(((
... ... @@ -797,9 +797,8 @@
797 797  
798 798  Table 6-1-1 Faults and solutions
799 799  
793 +== Common faults and solutions ==
800 800  
801 -== 6.2 Common faults and solutions ==
802 -
803 803  |**SN**|**Fault**|**Possible causes**|**Solutions**
804 804  |1|No display at power-on state|(((
805 805  ~1. The input power of AC Drive is abnormal.