Changes for page 1 VM Series Manual V1.2
Last modified by Mora Zhou on 2023/12/28 10:44
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 1VM AC Drive Manual1 +WECON VM AC Drive User Manual - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - VFD.WebHome1 +2\. User Manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.admin - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= 1Preface =1 += Preface = 2 2 3 3 Thank you for choosing WECON VM Series AC Drive. 4 4 ... ... @@ -9,7 +9,7 @@ 9 9 Be sure to verify that the wiring is correct before powering on the product. Before starting the product, it is necessary to debug to ensure correct motor rotating direction. 10 10 11 11 12 -= 2Safety precautions =12 += Safety precautions = 13 13 14 14 **■ Warning sign** 15 15 ... ... @@ -17,7 +17,7 @@ 17 17 18 18 [[image:WECON VM 英文 V01_html_b36792972403c101.png]] WARNING: Indicates that failure to comply with the notice will result in moderate personal injury, property damage or equipment damage. 19 19 20 - (% class="warning" %)|**WARNING**20 +|**WARNING** 21 21 |((( 22 22 ◎Do not install or operate any AC Drive that is damaged or with missing parts. Failing to follow this rule can result in facility damage or severe injury. 23 23 ... ... @@ -48,7 +48,7 @@ 48 48 ◎The PCB board has a CMOS integrated circuit. Do not touch it with your hands, otherwise, static electricity will damage the PCB board. 49 49 ))) 50 50 51 - (% class="warning" %)|**DANGER**51 +|**DANGER** 52 52 |((( 53 53 ◎Wiring must be completed by qualified professional electricians, otherwise, there may be electric shock or damage to the AC Drive. 54 54 ... ... @@ -77,11 +77,11 @@ 77 77 ◎Modification to the AC Drive without permission is strictly prohibited, otherwise, severe injury may be caused. Arbitrarily modification of AC Drive will result in service warranty invalid. 78 78 ))) 79 79 80 -= 3Product information =80 += Chapter 1 Product information = 81 81 82 -== Technical specifications == 82 +== 1.1 Technical specifications == 83 83 84 -| =(% colspan="2" %)**Item**|=**Specifications**84 +|(% colspan="2" %)**Item**|**Specifications** 85 85 |(% rowspan="7" %)Control features|Control mode|V/F control 86 86 |Startup torque|0.5Hz/100% 87 87 |Speed range|1:50 ... ... @@ -113,13 +113,13 @@ 113 113 114 114 Table 1-1-1 Technical specification shee 115 115 116 -== Product nameplate == 116 +== 1.2 Product nameplate == 117 117 118 118 [[image:WECON VM 英文 V01_html_5a52ff18546c8417.png]] 119 119 120 120 Figure 1-2-1 Product nameplate 121 121 122 -== Model description == 122 +== 1.3 Model description == 123 123 124 124 __VM__ – __2__ __S__ __1R5GB__ 125 125 ... ... @@ -133,7 +133,7 @@ 133 133 134 134 Table 1-3-1 VM series model field comment 135 135 136 -== Product model == 136 +== 1.4 Product model == 137 137 138 138 |(% rowspan="2" %)AC Drive Model|Rated power|Power capacity|Input current|Output current|(% colspan="2" %)Motor G/P 139 139 |kW|kVA|A|A|kW|HP ... ... @@ -151,12 +151,10 @@ 151 151 152 152 *:In development 153 153 154 -= 4 Installation = 155 155 156 -= =Overallstructuraldrawing==155 += Chapter 2 Installation = 157 157 158 -(% class="wikigeneratedid" %) 159 -unit: mm 157 +== 2.1 Overall structural drawing(unit:mm) == 160 160 161 161 [[image:1624240220324-243.png]] 162 162 ... ... @@ -176,14 +176,21 @@ 176 176 177 177 Table 2-1-1 outline dimension 178 178 179 -== Terminal connection == 177 +== 2.2 Terminal connection == 180 180 179 + 181 181 [[image:1624240272484-903.png]] 182 182 183 183 Figure 2-2-1 Terminal connection 184 184 185 -**Main circuit connection** 186 186 185 + 186 + 187 + 188 + 189 + 190 +* **Main circuit connection** 191 + 187 187 |**Terminal mark**|**Name**|**Description** 188 188 |R、S、T|Power supply input terminals|Connect to the AC power supply 189 189 |U、V、W|AC drive output terminals|Connect the three-phase motor. ... ... @@ -191,7 +191,7 @@ 191 191 192 192 Table 2-2-1 Main circuit terminals and function 193 193 194 -**Control circuit connection** 199 +* **Control circuit connection** 195 195 196 196 |**Category**|**Terminal symbol**|**Terminal name**|**Function description** 197 197 |(% rowspan="2" %)Power supply|+10V-GND|+10V power supply|((( ... ... @@ -211,9 +211,9 @@ 211 211 212 212 Table 2-2-2 Control terminal instruction 213 213 214 -= 5Display and operation =219 += Chapter 3 Display and operation = 215 215 216 -== Keypad == 221 +== 3.1 Keypad == 217 217 218 218 You can modify the parameters, monitor the working status and start or stop the AC Drive by operating the keypad, as shown in the following figure. 219 219 ... ... @@ -221,7 +221,7 @@ 221 221 222 222 Figure 3-1-1 Keypad diagram 223 223 224 -== Description of indicators and keys == 229 +== 3.2 Description of indicators and keys == 225 225 226 226 |**Item**|**Name**|**Function** 227 227 |Indicator|Status|((( ... ... @@ -248,8 +248,9 @@ 248 248 249 249 Table 3-2-1 Description of Indicators and key 250 250 251 -= 6 Parameter function = 252 252 257 += Chapter 4 Parameter function = 258 + 253 253 “○”: the parameter can be modified in both standby and operating state; 254 254 255 255 “●”: the parameter can’t be modified in operating state; ... ... @@ -258,8 +258,9 @@ 258 258 259 259 Note: the communication address is hexadecimal. 260 260 261 -== Functional parameter == 262 262 268 +== 4.1 Functional parameter == 269 + 263 263 |Parameter|Name|Setting Range|Default|Property|Address 264 264 |F0.00|Reserved|Reserved|0|●|0000 265 265 |F0.01|Command source selection|0:Operation panel control(LED off) ... ... @@ -521,7 +521,7 @@ 521 521 1:AI 522 522 )))|0|○|0D0F 523 523 524 -== Monitoring Parameters == 531 +== 4.2 Monitoring Parameters == 525 525 526 526 |Parameter|Name|Minimum Unit|Priority|Address 527 527 |D0.00|Running Frequency(Hz)|0.01Hz|◎|D000 ... ... @@ -538,7 +538,7 @@ 538 538 |D0.13|PLC Stage|1|◎|D013 539 539 |D0.14|Feedback Speed(Unit0.1Hz)|0.1Hz|◎|D014 540 540 541 -== Error Records == 548 +== 4.3 Error Records == 542 542 543 543 |Parameter|Name|Range and Description|Priority|Address 544 544 |E0.00|Latest error type|No Error:0 ... ... @@ -568,11 +568,11 @@ 568 568 |E1.04|Input terminals status at former error|0-63|●| E104 569 569 |E1.05|IGBT temperature at former error|0-65535|●| E105 570 570 571 -= 8Communication Protocol =578 += Chapter5 Communication Protocol = 572 572 573 573 VM Series AC Drive provides RS485 communication interface and supports Modbus communication protocol. Users can achieve centralized control by computer or PLC, set AC Drive operation commands, modify or read function code parameters, read the working state and fault info of the AC Drive. 574 574 575 -== Communication Control Address == 582 +== 5.1 Communication Control Address == 576 576 577 577 |Function|Address|Description|Remarks|Characteristic 578 578 |Communication Set Value|1000H|-10000~10000(with ± sign)|F0.05*(±100.00%)|R/W ... ... @@ -623,7 +623,7 @@ 623 623 624 624 Sheet 5-1-1 Control Command Addresses 625 625 626 -== EEPROM Addresses Introduction == 633 +== 5.2 EEPROM Addresses Introduction == 627 627 628 628 The addresses listed in the sheet above is the way of writing RAM. The RAM stores the data after power-off and does not save it. In the communication mode, for the write command "06H", if the parameter needs to be stored after power-off, the method of writing EEPROM should be used. The original "0" of the most significant bit of the RAM address is changed to "F", which is converted into the corresponding EEPROM address, for example: "0XXX" is changed to "FXXX" 629 629 ... ... @@ -635,9 +635,9 @@ 635 635 636 636 It should be noted that the erasing life of EEPROM is about 1 million times. After exceeding the erasing times, it will affect the reliability of data storage. If it is not necessary, it is recommended to control the communication by writing to RAM. 637 637 638 -= 9Troubleshooting & countermeasures =645 += Chapter 6 Troubleshooting & countermeasures = 639 639 640 -== Faults and solutions == 647 +== 6.1 Faults and solutions == 641 641 642 642 |Fault code|Fault type|Reason|Solution 643 643 |Err02|Overcurrent during acceleration|((( ... ... @@ -790,8 +790,9 @@ 790 790 791 791 Table 6-1-1 Faults and solutions 792 792 793 -== Common faults and solutions == 794 794 801 +== 6.2 Common faults and solutions == 802 + 795 795 |**SN**|**Fault**|**Possible causes**|**Solutions** 796 796 |1|No display at power-on state|((( 797 797 ~1. The input power of AC Drive is abnormal.