Changes for page 1 VM Series Manual V1.2

Last modified by Mora Zhou on 2023/12/28 10:44

From version 5.1
edited by Stone Wu
on 2022/08/01 14:31
Change comment: There is no comment for this version
To version 1.1
edited by Leo Wei
on 2022/06/08 14:51
Change comment: Imported from XAR

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -1 VM AC Drive Manual
1 +WECON VM AC Drive User Manual
Parent
... ... @@ -1,1 +1,1 @@
1 -VFD.WebHome
1 +2\. User Manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.admin
Content
... ... @@ -1,4 +1,4 @@
1 -= 1 Preface =
1 += Preface =
2 2  
3 3  Thank you for choosing WECON VM Series AC Drive.
4 4  
... ... @@ -9,7 +9,7 @@
9 9  Be sure to verify that the wiring is correct before powering on the product. Before starting the product, it is necessary to debug to ensure correct motor rotating direction.
10 10  
11 11  
12 -= 2 Safety precautions =
12 += Safety precautions =
13 13  
14 14  **■ Warning sign**
15 15  
... ... @@ -17,7 +17,7 @@
17 17  
18 18  [[image:WECON VM 英文 V01_html_b36792972403c101.png]] WARNING: Indicates that failure to comply with the notice will result in moderate personal injury, property damage or equipment damage.
19 19  
20 -(% class="warning" %)|**WARNING**
20 +|**WARNING**
21 21  |(((
22 22  ◎Do not install or operate any AC Drive that is damaged or with missing parts. Failing to follow this rule can result in facility damage or severe injury.
23 23  
... ... @@ -48,7 +48,7 @@
48 48  ◎The PCB board has a CMOS integrated circuit. Do not touch it with your hands, otherwise, static electricity will damage the PCB board.
49 49  )))
50 50  
51 -(% class="warning" %)|**DANGER**
51 +|**DANGER**
52 52  |(((
53 53  ◎Wiring must be completed by qualified professional electricians, otherwise, there may be electric shock or damage to the AC Drive.
54 54  
... ... @@ -77,11 +77,11 @@
77 77  ◎Modification to the AC Drive without permission is strictly prohibited, otherwise, severe injury may be caused. Arbitrarily modification of AC Drive will result in service warranty invalid.
78 78  )))
79 79  
80 -= 3 Product information =
80 += Chapter 1 Product information =
81 81  
82 -== Technical specifications ==
82 +== 1.1 Technical specifications ==
83 83  
84 -|=(% colspan="2" %)**Item**|=**Specifications**
84 +|(% colspan="2" %)**Item**|**Specifications**
85 85  |(% rowspan="7" %)Control features|Control mode|V/F control
86 86  |Startup torque|0.5Hz/100%
87 87  |Speed range|1:50
... ... @@ -113,13 +113,13 @@
113 113  
114 114  Table 1-1-1 Technical specification shee
115 115  
116 -== Product nameplate ==
116 +== 1.2 Product nameplate ==
117 117  
118 118  [[image:WECON VM 英文 V01_html_5a52ff18546c8417.png]]
119 119  
120 120  Figure 1-2-1 Product nameplate
121 121  
122 -== Model description ==
122 +== 1.3 Model description ==
123 123  
124 124  __VM__ – __2__ __S__ __1R5GB__
125 125  
... ... @@ -133,7 +133,7 @@
133 133  
134 134  Table 1-3-1 VM series model field comment
135 135  
136 -== Product model ==
136 +== 1.4 Product model ==
137 137  
138 138  |(% rowspan="2" %)AC Drive Model|Rated power|Power capacity|Input current|Output current|(% colspan="2" %)Motor G/P
139 139  |kW|kVA|A|A|kW|HP
... ... @@ -151,12 +151,10 @@
151 151  
152 152  *:In development
153 153  
154 -= 4 Installation =
155 155  
156 -== Overall structural drawing ==
155 += Chapter 2 Installation =
157 157  
158 -(% class="wikigeneratedid" %)
159 -unit: mm
157 +== 2.1 Overall structural drawing(unit:mm) ==
160 160  
161 161  [[image:1624240220324-243.png]]
162 162  
... ... @@ -176,14 +176,21 @@
176 176  
177 177  Table 2-1-1 outline dimension
178 178  
179 -== Terminal connection ==
177 +== 2.2 Terminal connection ==
180 180  
179 +
181 181  [[image:1624240272484-903.png]]
182 182  
183 183  Figure 2-2-1 Terminal connection
184 184  
185 -**Main circuit connection**
186 186  
185 +
186 +
187 +
188 +
189 +
190 +* **Main circuit connection**
191 +
187 187  |**Terminal mark**|**Name**|**Description**
188 188  |R、S、T|Power supply input terminals|Connect to the AC power supply
189 189  |U、V、W|AC drive output terminals|Connect the three-phase motor.
... ... @@ -191,7 +191,7 @@
191 191  
192 192  Table 2-2-1 Main circuit terminals and function
193 193  
194 -**Control circuit connection**
199 +* **Control circuit connection**
195 195  
196 196  |**Category**|**Terminal symbol**|**Terminal name**|**Function description**
197 197  |(% rowspan="2" %)Power supply|+10V-GND|+10V power supply|(((
... ... @@ -211,9 +211,9 @@
211 211  
212 212  Table 2-2-2 Control terminal instruction
213 213  
214 -= 5 Display and operation =
219 += Chapter 3 Display and operation =
215 215  
216 -== Keypad ==
221 +== 3.1 Keypad ==
217 217  
218 218  You can modify the parameters, monitor the working status and start or stop the AC Drive by operating the keypad, as shown in the following figure.
219 219  
... ... @@ -221,7 +221,7 @@
221 221  
222 222  Figure 3-1-1 Keypad diagram
223 223  
224 -== Description of indicators and keys ==
229 +== 3.2 Description of indicators and keys ==
225 225  
226 226  |**Item**|**Name**|**Function**
227 227  |Indicator|Status|(((
... ... @@ -248,8 +248,9 @@
248 248  
249 249  Table 3-2-1 Description of Indicators and key
250 250  
251 -= 6 Parameter function =
252 252  
257 += Chapter 4 Parameter function =
258 +
253 253  “○”: the parameter can be modified in both standby and operating state;
254 254  
255 255  “●”: the parameter can’t be modified in operating state;
... ... @@ -258,8 +258,9 @@
258 258  
259 259  Note: the communication address is hexadecimal.
260 260  
261 -== Functional parameter ==
262 262  
268 +== 4.1 Functional parameter ==
269 +
263 263  |Parameter|Name|Setting Range|Default|Property|Address
264 264  |F0.00|Reserved|Reserved|0|●|0000
265 265  |F0.01|Command source selection|0:Operation panel control(LED off)
... ... @@ -521,7 +521,7 @@
521 521  1:AI
522 522  )))|0|○|0D0F
523 523  
524 -== Monitoring Parameters ==
531 +== 4.2 Monitoring Parameters ==
525 525  
526 526  |Parameter|Name|Minimum Unit|Priority|Address
527 527  |D0.00|Running Frequency(Hz)|0.01Hz|◎|D000
... ... @@ -538,7 +538,7 @@
538 538  |D0.13|PLC Stage|1|◎|D013
539 539  |D0.14|Feedback Speed(Unit0.1Hz)|0.1Hz|◎|D014
540 540  
541 -== Error Records ==
548 +== 4.3 Error Records ==
542 542  
543 543  |Parameter|Name|Range and Description|Priority|Address
544 544  |E0.00|Latest error type|No Error:0
... ... @@ -568,11 +568,11 @@
568 568  |E1.04|Input terminals status at former error|0-63|●| E104
569 569  |E1.05|IGBT temperature at former error|0-65535|●| E105
570 570  
571 -= 8 Communication Protocol =
578 += Chapter5 Communication Protocol =
572 572  
573 573  VM Series AC Drive provides RS485 communication interface and supports Modbus communication protocol. Users can achieve centralized control by computer or PLC, set AC Drive operation commands, modify or read function code parameters, read the working state and fault info of the AC Drive.
574 574  
575 -== Communication Control Address ==
582 +== 5.1 Communication Control Address ==
576 576  
577 577  |Function|Address|Description|Remarks|Characteristic
578 578  |Communication Set Value|1000H|-10000~10000(with ± sign)|F0.05*(±100.00%)|R/W
... ... @@ -623,7 +623,7 @@
623 623  
624 624  Sheet 5-1-1 Control Command Addresses
625 625  
626 -== EEPROM Addresses Introduction ==
633 +== 5.2 EEPROM Addresses Introduction ==
627 627  
628 628  The addresses listed in the sheet above is the way of writing RAM. The RAM stores the data after power-off and does not save it. In the communication mode, for the write command "06H", if the parameter needs to be stored after power-off, the method of writing EEPROM should be used. The original "0" of the most significant bit of the RAM address is changed to "F", which is converted into the corresponding EEPROM address, for example: "0XXX" is changed to "FXXX"
629 629  
... ... @@ -635,9 +635,9 @@
635 635  
636 636  It should be noted that the erasing life of EEPROM is about 1 million times. After exceeding the erasing times, it will affect the reliability of data storage. If it is not necessary, it is recommended to control the communication by writing to RAM.
637 637  
638 -= 9 Troubleshooting & countermeasures =
645 += Chapter 6 Troubleshooting & countermeasures =
639 639  
640 -== Faults and solutions ==
647 +== 6.1 Faults and solutions ==
641 641  
642 642  |Fault code|Fault type|Reason|Solution
643 643  |Err02|Overcurrent during acceleration|(((
... ... @@ -790,8 +790,9 @@
790 790  
791 791  Table 6-1-1 Faults and solutions
792 792  
793 -== Common faults and solutions ==
794 794  
801 +== 6.2 Common faults and solutions ==
802 +
795 795  |**SN**|**Fault**|**Possible causes**|**Solutions**
796 796  |1|No display at power-on state|(((
797 797  ~1. The input power of AC Drive is abnormal.