Changes for page 1 VM Series Manual V1.2
Last modified by Mora Zhou on 2023/12/28 10:44
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 VM AC Drive Manual 1 +1 VM AC Drive User Manual - Content
-
... ... @@ -1,10 +1,5 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -**This is the old version VM series. S/N on the inverter starts from "X0".** 4 -))) 1 += Preface = 5 5 6 -= 1 Preface = 7 - 8 8 Thank you for choosing WECON VM Series AC Drive. 9 9 10 10 This user manual introduces the technical specifications, installation instructions, functions and performance of VM Series AC Drive properly. Please read this user manual carefully before carrying out works such as installation, commissioning, maintenance, etc. ... ... @@ -13,8 +13,9 @@ 13 13 14 14 Be sure to verify that the wiring is correct before powering on the product. Before starting the product, it is necessary to debug to ensure correct motor rotating direction. 15 15 16 -= 2 Safety precautions = 17 17 12 += Safety precautions = 13 + 18 18 **■ Warning sign** 19 19 20 20 [[image:WECON VM 英文 V01_html_f697a083b5da7fc8.png]] DANGER: Indicates that failure to comply with the notice will result in severe personal injure or even death. ... ... @@ -21,7 +21,7 @@ 21 21 22 22 [[image:WECON VM 英文 V01_html_b36792972403c101.png]] WARNING: Indicates that failure to comply with the notice will result in moderate personal injury, property damage or equipment damage. 23 23 24 - (% class="warning" %)|**WARNING**20 +|**WARNING** 25 25 |((( 26 26 ◎Do not install or operate any AC Drive that is damaged or with missing parts. Failing to follow this rule can result in facility damage or severe injury. 27 27 ... ... @@ -52,7 +52,7 @@ 52 52 ◎The PCB board has a CMOS integrated circuit. Do not touch it with your hands, otherwise, static electricity will damage the PCB board. 53 53 ))) 54 54 55 - (% class="warning" %)|**DANGER**51 +|**DANGER** 56 56 |((( 57 57 ◎Wiring must be completed by qualified professional electricians, otherwise, there may be electric shock or damage to the AC Drive. 58 58 ... ... @@ -81,28 +81,28 @@ 81 81 ◎Modification to the AC Drive without permission is strictly prohibited, otherwise, severe injury may be caused. Arbitrarily modification of AC Drive will result in service warranty invalid. 82 82 ))) 83 83 84 -= 3Product information =80 += Chapter 1 Product information = 85 85 86 -== Technical specifications == 82 +== 1.1 Technical specifications == 87 87 88 -| =(% colspan="2" %)**Item**|=**Specifications**84 +|(% colspan="2" %)**Item**|**Specifications** 89 89 |(% rowspan="7" %)Control features|Control mode|V/F control 90 90 |Startup torque|0.5Hz/100% 91 -|Speed range|1 :5087 +|Speed range|1:50 92 92 |Speed stability accuracy|±1% 93 -|Carrier frequency|1kHz ~~6kHz;89 +|Carrier frequency|1kHz ~ 6kHz; 94 94 |Overload capacity|60s for 150% of the rated current, 1s for 180% of the rated current. 95 -|Torque boost|0.0% ~~30.0%96 -|(% rowspan="4" %)Input and Output|Input voltage range|220V/380V; fluctuation range :±15%97 -|Input frequency range|50/60Hz;fluctuation range :±5%91 +|Torque boost|0.0% ~ 30.0% 92 +|(% rowspan="4" %)Input and Output|Input voltage range|220V/380V; fluctuation range :±15% 93 +|Input frequency range|50/60Hz;fluctuation range :±5% 98 98 |Output voltage range|0-input voltage; the error is less than 5% 99 -|Output frequency range|0 ~~400Hz95 +|Output frequency range|0-400Hz 100 100 |(% rowspan="5" %)Basic function|Running command source|Three command source:keypad; control terminals; serial communication port. 101 101 |Frequency source|such as digital setting, analog voltage setting, analog current setting, serial communication port setting. 102 102 |DC braking|((( 103 -Braking time: 0.0s ~~50.0s;99 +Braking time: 0.0s ~ 50.0s; 104 104 105 -Braking action current value: 0.0% ~~100.0%101 +Braking action current value: 0.0% ~ 100.0% 106 106 ))) 107 107 |Simple PLC/Multiple speeds|It implements up to 8 speeds via the simple PLC function or combination of DI terminal states. 108 108 |Protection mode|Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection and so on. ... ... @@ -110,7 +110,7 @@ 110 110 |Parameters locking function|It can lock the parameters to prevent malfunction. 111 111 |(% rowspan="6" %)Environment|Installation location|Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt. 112 112 |Altitude|Lower than 1000m. When it is higher than 1000m, for every 100m, it needs to reduce power by 1%, and the maximum altitude is 3000m. 113 -|Ambient temperature|-10℃ ~~50℃. When it is higher than 40℃, for every 1℃, it needs to reduce power by 1%, and the maximum ambient temperature is 50℃109 +|Ambient temperature|-10℃~ 50℃. When it is higher than 40℃, for every 1℃, it needs to reduce power by 1%, and the maximum ambient temperature is 50℃ 114 114 |Humidity|≤95%RH, without condensing 115 115 |Vibration|Less than 5.9m/s2 (0.6g) 116 116 |Storage temperature|-25℃~+60℃ ... ... @@ -117,100 +117,92 @@ 117 117 118 118 Table 1-1-1 Technical specification shee 119 119 120 -== Product nameplate == 116 +== 1.2 Product nameplate == 121 121 122 -(% style="text-align:center" %) 123 -((( 124 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 125 -[[Figure 1-2-1 Product nameplate>>image:WECON VM 英文 V01_html_5a52ff18546c8417.png||id="IWECONVMA082F16587A0V01_html_5a52ff18546c8417.png"]] 126 -))) 118 +[[image:WECON VM 英文 V01_html_5a52ff18546c8417.png]] 127 127 120 +Figure 1-2-1 Product nameplate 128 128 129 -== Model description == 122 +== 1.3 Model description == 130 130 131 131 __VM__ – __2__ __S__ __1R5GB__ 132 132 133 133 ① ② ③ ④ 134 134 135 -| =**Field**|=**No.**|=**Identification**|=**Description**128 +|**Field**|**No.**|**Identification**|**Description** 136 136 |Product series|①|Product series|VM series 137 -|Voltage grade|②|Voltage grade|2 :220VAC;4:380VAC138 -|The input power|③|Power phase identification|S: single ;T: three-phase130 +|Voltage grade|②|Voltage grade|2:220VAC; 4:380VAC 131 +|The input power|③|Power phase identification|S: single ; T: three-phase 139 139 |Rated power|④|Power range|1R5-1.5kW,R is the decimal point 140 140 141 141 Table 1-3-1 VM series model field comment 142 142 143 -== Product model == 136 +== 1.4 Product model == 144 144 145 -| =(% rowspan="2"scope="row"%)AC Drive Model|=Rated power|=Power capacity|=Input current|=(% style="width: 173px;" %)Output current|=(% colspan="2"style="width: 199px;"%)Motor G/P146 -| =kW|=kVA|=A|=(% style="width: 173px;" %)A|=(% style="width: 128px;" %)kW|=HP147 -| =VM-2SR75|0.75|1.5|8.2|(% style="width:173px" %)4|(% style="width:128px" %)0.75|1148 -| =VM-2S1R5|1.5|3|14.2|(% style="width:173px" %)7|(% style="width:128px" %)1.5|2149 -| =VM-2S2R2|2.2|4|23|(% style="width:173px" %)9.6|(% style="width:128px" %)2.2|3150 -| =VM-4T2R2|2.2|4|5.8|(% style="width:173px" %)5.1|(% style="width:128px" %)2.2|3151 -| =VM-4T004|4|5.9|10.5|(% style="width:173px" %)9|(% style="width:128px" %)4/|5.5152 -| =VM-4T5R5|5.5|8.9|14.6|(% style="width:173px" %)13|(% style="width:128px" %)5.5|7.5153 -| =VM-4T7R5|7.5|11|20.5|(% style="width:173px" %)17|(% style="width:128px" %)7.5|10154 -| =VM-4T011*|11|17|26|(% style="width:173px" %)25|(% style="width:128px" %)11|15155 -| =VM-4T015*|15|21|35|(% style="width:173px" %)32|(% style="width:128px" %)15|20138 +|(% rowspan="2" %)AC Drive Model|Rated power|Power capacity|Input current|Output current|(% colspan="2" %)Motor G/P 139 +|kW|kVA|A|A|kW|HP 140 +|VM-2SR75|0.75|1.5|8.2|4|0.75|1 141 +|VM-2S1R5|1.5|3|14.2|7|1.5|2 142 +|VM-2S2R2|2.2|4|23|9.6|2.2|3 143 +|VM-4T2R2|2.2|4|5.8|5.1|2.2|3 144 +|VM-4T004|4|5.9|10.5|9|4/|5.5 145 +|VM-4T5R5|5.5|8.9|14.6|13|5.5|7.5 146 +|VM-4T7R5|7.5|11|20.5|17|7.5|10 147 +|VM-4T011*|11|17|26|25|11|15 148 +|VM-4T015*|15|21|35|32|15|20 156 156 157 157 Table 1-4-1 Product model table 158 158 159 -(% class="box infomessage" %) 160 -((( 161 161 *:In development 162 -))) 163 163 164 -= 4 Installation = 165 165 166 -= =Overallstructuraldrawing==155 += Chapter 2 Installation = 167 167 168 -(% class="wikigeneratedid" %) 169 -unit: mm 157 +== 2.1 Overall structural drawing(unit:mm) == 170 170 171 -(% style="text-align:center" %) 172 -((( 173 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 174 -[[Figure 2-1-1 Outline dimension diagram>>image:1624240220324-243.png||id="I1624240220324-243.png"]] 175 -))) 159 +[[image:1624240220324-243.png]] 176 176 161 +Figure 2-1-1 Outline dimension diagram 177 177 178 -(% style="width:1271.22px" %) 179 -|=(% rowspan="2" scope="row" style="width: 267px;" %)AC Drive Model|=(% colspan="3" style="width: 384px;" %)Overall Dimensions|=(% colspan="2" style="width: 294px;" %)Mounting Hole|=(% style="width: 259px;" %)Mounting Hole Diameter 180 -|=(% style="width: 118px;" %)H|=(% style="width: 120px;" %)W|=(% style="width: 145px;" %)D|=(% style="width: 147px;" %)H1|=(% style="width: 147px;" %)W1|=(% style="width: 259px;" %)d 181 -|=(% style="width: 267px;" %)VM-2SR75|(% rowspan="2" style="width:118px" %)134|(% rowspan="2" style="width:120px" %)69|(% rowspan="2" style="width:145px" %)104|(% rowspan="2" style="width:147px" %)123|(% rowspan="2" style="width:147px" %)55|(% rowspan="2" style="width:259px" %)5 182 -|=(% style="width: 267px;" %)VM-2S1R5 183 -|=(% style="width: 267px;" %)VM-2S2R2|(% rowspan="2" style="width:118px" %)142|(% rowspan="2" style="width:120px" %)72|(% rowspan="2" style="width:145px" %)116|(% rowspan="2" style="width:147px" %)130|(% rowspan="2" style="width:147px" %)59|(% rowspan="2" style="width:259px" %)5 184 -|=(% style="width: 267px;" %)VM-4T2R2 185 -|=(% style="width: 267px;" %)VM-4T004|(% style="width:118px" %)196|(% style="width:120px" %)95|(% style="width:145px" %)132|(% style="width:147px" %)179|(% style="width:147px" %)79|(% style="width:259px" %)5.5 186 -|=(% style="width: 267px;" %)VM-4T5R5|(% rowspan="2" style="width:118px" %)225|(% rowspan="2" style="width:120px" %)115|(% rowspan="2" style="width:145px" %)154|(% rowspan="2" style="width:147px" %)208|(% rowspan="2" style="width:147px" %)99|(% rowspan="2" style="width:259px" %)5.5 187 -|=(% style="width: 267px;" %)VM-4T7R5 188 -|=(% style="width: 267px;" %)VM-4T011|(% style="width:118px" %)-|(% style="width:120px" %)-|(% style="width:145px" %)-|(% style="width:147px" %)-|(% style="width:147px" %)-|(% style="width:259px" %)- 189 -|=(% style="width: 267px;" %)VM-4T015|(% style="width:118px" %)-|(% style="width:120px" %)-|(% style="width:145px" %)-|(% style="width:147px" %)-|(% style="width:147px" %)-|(% style="width:259px" %)- 163 +|(% rowspan="2" %)AC Drive Model|(% colspan="3" %)Overall Dimensions|(% colspan="2" %)Mounting Hole|Mounting Hole Diameter 164 +|H|W|D|H1|W1|d 165 +|VM-2SR75|(% rowspan="2" %)134|(% rowspan="2" %)69|(% rowspan="2" %)104|(% rowspan="2" %)123|(% rowspan="2" %)55|(% rowspan="2" %)5 166 +|VM-2S1R5 167 +|VM-2S2R2|(% rowspan="2" %)142|(% rowspan="2" %)72|(% rowspan="2" %)116|(% rowspan="2" %)130|(% rowspan="2" %)59|(% rowspan="2" %)5 168 +|VM-4T2R2 169 +|VM-4T004|196|95|132|179|79|5.5 170 +|VM-4T5R5|(% rowspan="2" %)225|(% rowspan="2" %)115|(% rowspan="2" %)154|(% rowspan="2" %)208|(% rowspan="2" %)99|(% rowspan="2" %)5.5 171 +|VM-4T7R5 172 +|VM-4T011|-|-|-|-|-|- 173 +|VM-4T015|-|-|-|-|-|- 190 190 191 191 Table 2-1-1 outline dimension 192 192 193 -== Terminal connection == 177 +== 2.2 Terminal connection == 194 194 195 -(% style="text-align:center" %) 196 -((( 197 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 198 -[[Figure 2-2-1 Terminal connection>>image:1624240272484-903.png||id="I1624240272484-903.png"]] 199 -))) 200 200 180 +[[image:1624240272484-903.png]] 201 201 202 - **Maincircuitconnection**182 +Figure 2-2-1 Terminal connection 203 203 204 -|=(% scope="row" %)**Terminal mark**|=**Name**|=**Description** 205 -|=R、S、T|Power supply input terminals|Connect to the AC power supply 206 -|=U、V、W|AC drive output terminals|Connect the three-phase motor. 207 -|=[[image:WECON VM 英文 V01_html_2b5dc89a424d22e6.png||height="22" width="23"]]|Grounding terminal|Must be grounded. 208 208 185 + 186 + 187 + 188 + 189 + 190 +* **Main circuit connection** 191 + 192 +|**Terminal mark**|**Name**|**Description** 193 +|R、S、T|Power supply input terminals|Connect to the AC power supply 194 +|U、V、W|AC drive output terminals|Connect the three-phase motor. 195 +|[[image:WECON VM 英文 V01_html_2b5dc89a424d22e6.png||height="22" width="23"]]|Grounding terminal|Must be grounded. 196 + 209 209 Table 2-2-1 Main circuit terminals and function 210 210 211 -**Control circuit connection** 199 +* **Control circuit connection** 212 212 213 -| =**Category**|=**Terminal symbol**|=**Terminal name**|=**Function description**201 +|**Category**|**Terminal symbol**|**Terminal name**|**Function description** 214 214 |(% rowspan="2" %)Power supply|+10V-GND|+10V power supply|((( 215 215 Provide +10V power supply to external unit. 216 216 ... ... @@ -228,347 +228,320 @@ 228 228 229 229 Table 2-2-2 Control terminal instruction 230 230 231 -= 5Display and operation =219 += Chapter 3 Display and operation = 232 232 233 -== Keypad == 221 +== 3.1 Keypad == 234 234 235 235 You can modify the parameters, monitor the working status and start or stop the AC Drive by operating the keypad, as shown in the following figure. 236 236 237 -(% style="text-align:center" %) 238 -((( 239 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 240 -[[Figure 3-1-1 Keypad diagram>>image:WECON VM 英文 V01_html_53c6de9f2105008c.png||height="302" id="IWECONVMA082F16587A0V01_html_53c6de9f2105008c.png" width="280"]] 241 -))) 225 +[[image:WECON VM 英文 V01_html_53c6de9f2105008c.png||height="302" width="280"]] 242 242 227 +Figure 3-1-1 Keypad diagram 243 243 244 -== Description of indicators and keys == 229 +== 3.2 Description of indicators and keys == 245 245 246 -| =(% scope="row" %)**Item**|=(% style="width: 213px;" %)**Name**|=(% style="width: 865px;" %)**Function**247 -| =Indicator|(% style="width:213px" %)Status|(% style="width:865px" %)(((248 -* RUN :ON/Running;OFF/Stop.249 -* REMOTE :ON/Terminal control;Blinking/Communication;OFF/keypad control.250 -* FWD/REV :ON/Forward rotation;OFF/Reverse rotation;Blinking/Forward and reverse switching.251 -* ALARM :Blinking /Fault state.231 +|**Item**|**Name**|**Function** 232 +|Indicator|Status|((( 233 +* RUN: ON/Running;OFF/Stop. 234 +* REMOTE:ON/Terminal control;Blinking/Communication;OFF/keypad control. 235 +* FWD/REV: ON/Forward rotation;OFF/Reverse rotation;Blinking/Forward and reverse switching. 236 +* ALARM:Blinking /Fault state. 252 252 ))) 253 -|=(% rowspan="6" %)Keys|(% style="width:213px" %)((( 254 -PRG (Programming) 255 -)))|(% style="width:865px" %)Enter or exit the first menu. 256 -|(% scope="row" style="width:213px" %)ENT (Confirm)|(% style="width:865px" %)Enter the menu interfaces and confirm the parameter setting. 257 -|(% scope="row" style="width:213px" %)△(Increment)|(% style="width:865px" %)Increase date or function code. 258 -|(% scope="row" style="width:213px" %)▽(Decrement)|(% style="width:865px" %)Decrease data or function code. 259 -|(% scope="row" style="width:213px" %)<<(Shift)|(% style="width:865px" %)Select the displayed parameters in the stop or running state and select the digit to be modified when modifying parameters. 260 -|(% scope="row" style="width:213px" %)RUN/STOP|(% style="width:865px" %)((( 238 +|(% rowspan="6" %)keys|((( 239 +PRG 240 + 241 +(Programming) 242 +)))|Enter or exit the first menu. 243 +|ENT (Confirm)|Enter the menu interfaces and confirm the parameter setting. 244 +|△(Increment)|Increase date or function code. 245 +|▽(Decrement)|Decrease data or function code. 246 +|<<(Shift)|Select the displayed parameters in the stop or running state and select the digit to be modified when modifying parameters. 247 +|RUN/STOP|((( 261 261 Control drive start and stop in keypad control mode. 262 262 263 263 Perform the reset operation when it is in the fault state. 264 264 ))) 265 -| =Potentiometer|(% style="width:213px" %)Resistance potentiometer|(% style="width:865px" %)Frequency adjustment in keyboard operation mode252 +|potentiometer|Resistance potentiometer|Frequency adjustment in keyboard operation mode 266 266 267 267 Table 3-2-1 Description of Indicators and key 268 268 269 -= 6 Parameter function = 270 270 271 -* “○”: the parameter can be modified in both standby and operating state; 272 -* “●”: the parameter can’t be modified in operating state; 273 -* “◎”:the parameter is the actual detected and recorded value which can’t be modified; 257 += Chapter 4 Parameter function = 274 274 275 -(% class="box infomessage" %) 276 -((( 277 -**Note: **the communication address is hexadecimal. 278 -))) 259 +“○”: the parameter can be modified in both standby and operating state; 279 279 280 - ==Functionalparameter==261 +“●”: the parameter can’t be modified in operating state; 281 281 282 -|=(% scope="row" style="width: 97px;" %)Parameter|=(% style="width: 320px;" %)Name|=(% style="width: 428px;" %)Setting Range|=(% style="width: 196px;" %)Default|=(% style="width: 64px;" %)Property|=(% style="width: 87px;" %)Address 283 -|=(% style="width: 97px;" %)F0.00|(% style="width:320px" %)Reserved|(% style="width:428px" %)Reserved|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0000 284 -|=(% style="width: 97px;" %)F0.01|(% style="width:320px" %)Command source selection|(% style="width:428px" %)((( 285 -* 0:Operation panel control(LED off) 286 -* 1:Terminal control(LED on) 287 -* 2:Communication LED (LED blinking) 288 -)))|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0001 289 -|=(% style="width: 97px;" %)F0.02|(% style="width:320px" %)Setting main frequency source X|(% style="width:428px" %)((( 290 -* 0:Digital setting (non-retentive at power failure) 291 -* 1:Digital setting (retentive at power failure) 292 -* 2:Keypad Knob 293 -* 3:AI 294 -* 4:Multi-stage speed 295 -* 5:Simple PLC 296 -* 6:Communication 297 -)))|(% style="width:196px" %)2|(% style="width:64px" %)●|(% style="width:87px" %)0002 298 -|=(% style="width: 97px;" %)F0.03|(% style="width:320px" %)Keypad setting frequency|(% style="width:428px" %)0.00Hz~F0.05|(% style="width:196px" %)50.0Hz|(% style="width:64px" %)○|(% style="width:87px" %)0003 299 -|=(% style="width: 97px;" %)F0.04|(% style="width:320px" %)Running direction selection|(% style="width:428px" %)((( 300 -* 0:Forward 301 -* 1:Reverse 302 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0004 303 -|=(% style="width: 97px;" %)F0.05|(% style="width:320px" %)Maximum Output Frequency|(% style="width:428px" %)50.00Hz~400.00Hz|(% style="width:196px" %)50.0Hz|(% style="width:64px" %)●|(% style="width:87px" %)0005 304 -|=(% style="width: 97px;" %)F0.06|(% style="width:320px" %)Upper Limit of Frequency|(% style="width:428px" %)F0.07~F0.05|(% style="width:196px" %)50.0Hz|(% style="width:64px" %)○|(% style="width:87px" %)0006 305 -|=(% style="width: 97px;" %)F0.07|(% style="width:320px" %)Lower Limit of Frequency|(% style="width:428px" %)0.00Hz~F0.06|(% style="width:196px" %)0.0Hz|(% style="width:64px" %)○|(% style="width:87px" %)0007 306 -|=(% style="width: 97px;" %)F0.08|(% style="width:320px" %)The option of frequency lower limit|(% style="width:428px" %)((( 307 -* 0:Running at frequency lower limit 308 -* 1:Stop 309 -* 2:Standby 310 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0008 311 -|=(% style="width: 97px;" %)F0.09|(% style="width:320px" %)Carrier Frequency|(% style="width:428px" %)1kHz~6.0kHz|(% style="width:196px" %)6.0kHz|(% style="width:64px" %)●|(% style="width:87px" %)0009 312 -|=(% style="width: 97px;" %)F0.10|(% style="width:320px" %)Acceleration Time 1|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)10.0s|(% style="width:64px" %)○|(% style="width:87px" %)000A 313 -|=(% style="width: 97px;" %)F0.11|(% style="width:320px" %)Deceleration Time 1|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)10.0s|(% style="width:64px" %)○|(% style="width:87px" %)000B 314 -|=(% style="width: 97px;" %)F0.12|(% style="width:320px" %)Stop Mode|(% style="width:428px" %)((( 315 -* 0:Decelerate to stop 316 -* 1:Free stop 317 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)000C 318 -|=(% style="width: 97px;" %)F0.13|(% style="width:320px" %)Retentive of digital setting frequency|(% style="width:428px" %)((( 319 -* 0:No retentive 320 -* 1:retentive 321 -)))|(% style="width:196px" %)1|(% style="width:64px" %)●|(% style="width:87px" %)000D 322 -|=(% style="width: 97px;" %)F0.14|(% style="width:320px" %)Fan operating mode|(% style="width:428px" %)((( 323 -* 0:Run when motor is running 324 -* 1:Keep run when power on 325 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)000E 326 -|=(% style="width: 97px;" %)F0.15|(% style="width:320px" %)AI1 Input Option|(% style="width:428px" %)((( 327 -* 0: 0-10V 328 -* 1: 4-20mA 329 -* 2: 0-20mA 330 -* 3: 0-5V 331 -* 4: 0.5-4.5V 332 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)000F 333 -|=(% style="width: 97px;" %)F1.00|(% style="width:320px" %)Default Setting Restoring|(% style="width:428px" %)((( 334 -* 0: No Operation 335 -* 1: Restore to factory default setting (not including F2 parameters) 336 -* 2: Clear error records 337 -)))|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0100 338 -|=(% style="width: 97px;" %)F1.01|(% style="width:320px" %)Parameters Lockup|(% style="width:428px" %)((( 339 -* 0: Invalid 340 -* 1: Valid 341 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0101 342 -|=(% style="width: 97px;" %)F1.02|(% style="width:320px" %)User Password|(% style="width:428px" %)0~~65000|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0102 343 -|=(% style="width: 97px;" %)F2.00|(% style="width:320px" %)Motor Rated Power|(% style="width:428px" %)0.1kW~~2.2kW|(% style="width:196px" %)Determined by Drive Model|(% style="width:64px" %)●|(% style="width:87px" %)0200 344 -|=(% style="width: 97px;" %)F2.01|(% style="width:320px" %)Motor Rated Voltage|(% style="width:428px" %)0~~380V|(% style="width:196px" %)Determined by Drive Model|(% style="width:64px" %)●|(% style="width:87px" %)0201 345 -|=(% style="width: 97px;" %)F2.02|(% style="width:320px" %)Motor Rated Frequency|(% style="width:428px" %)0~~ F0.05|(% style="width:196px" %)Determined by Drive Model|(% style="width:64px" %)●|(% style="width:87px" %)0202 346 -|=(% style="width: 97px;" %)F2.03|(% style="width:320px" %)Motor Rated Current|(% style="width:428px" %)1.00~~10.00|(% style="width:196px" %)Determined by Drive Model|(% style="width:64px" %)●|(% style="width:87px" %)0203 347 -|=(% style="width: 97px;" %)F2.05|(% style="width:320px" %)Type of Motor|(% style="width:428px" %)((( 348 -* 0: Single Phase 349 -* 1: Three Phase 350 -)))|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0205 351 -|=(% style="width: 97px;" %)F2.06|(% style="width:320px" %)Single-phase motor main and auxiliary winding turns ratio|(% style="width:428px" %)10~~200|(% style="width:196px" %)80|(% style="width:64px" %)○|(% style="width:87px" %)0206 352 -|=(% style="width: 97px;" %)F2.07|(% style="width:320px" %)Single-phase motor current correction factor|(% style="width:428px" %)50~~200|(% style="width:196px" %)130|(% style="width:64px" %)○|(% style="width:87px" %)0207 353 -|=(% style="width: 97px;" %)F4.00|(% style="width:320px" %)Torque Boost|(% style="width:428px" %)0.0%~~30.0%|(% style="width:196px" %)4.0%|(% style="width:64px" %)○|(% style="width:87px" %)0400 354 -|=(% style="width: 97px;" %)F4.01|(% style="width:320px" %)Cut-off frequency of torque boost|(% style="width:428px" %)0.00Hz~F0.05|(% style="width:196px" %)50.00Hz|(% style="width:64px" %)●|(% style="width:87px" %)0401 355 -|=(% style="width: 97px;" %)F4.02|(% style="width:320px" %)Trigging frequency of DC braking at stop|(% style="width:428px" %)0.00Hz~F0.05|(% style="width:196px" %)0.00Hz|(% style="width:64px" %)○|(% style="width:87px" %)0402 356 -|=(% style="width: 97px;" %)F4.03|(% style="width:320px" %)Delay time of DC braking at stop|(% style="width:428px" %)0.0s~50.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)0403 357 -|=(% style="width: 97px;" %)F4.04|(% style="width:320px" %)The current of DC braking at stop|(% style="width:428px" %)0~100%|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0404 358 -|=(% style="width: 97px;" %)F4.05|(% style="width:320px" %)The time of DC braking at stop|(% style="width:428px" %)0.0s~50.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)0405 359 -|=(% style="width: 97px;" %)F4.06|(% style="width:320px" %)Automatic adjustment of carrier Frequency|(% style="width:428px" %)((( 360 -* 0: Invalid; 361 -* 1: Valid 362 -)))|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0406 363 -|=(% style="width: 97px;" %)F4.07|(% style="width:320px" %)0 frequency output option|(% style="width:428px" %)((( 364 -* 0: Valid; 365 -* 1: Invalid 366 -)))|(% style="width:196px" %)1|(% style="width:64px" %)●|(% style="width:87px" %)0407 367 -|=(% style="width: 97px;" %)F5.00|(% style="width:320px" %)DI1 terminal function selection|(% rowspan="4" style="width:428px" %)((( 368 -* 0: No function 369 -* 1: Forward running (FWD) 370 -* 2: Reverse running (REV) 371 -* 3: Three-wire operation control 372 -* 4: Forward point movement (FJOG) 373 -* 5: Reverse point movement (RJOG) 374 -* 6: Error Reset 375 -* 7: Terminal UP 376 -* 8: Terminal Down 377 -* 9: UP/DOWN Setting Clear 378 -* 10: External error input(Normally Open) 379 -* 11: PLC Status reset 380 -* 12: Multi stage speed terminal 1 381 -* 13: Multi stage speed terminal 2 382 -* 14: Reserved 383 -)))|(% style="width:196px" %)1|(% style="width:64px" %)●|(% style="width:87px" %)0500 384 -|=(% style="width: 97px;" %)F5.01|(% style="width:320px" %)DI2 terminal function selection|(% style="width:196px" %)2|(% style="width:64px" %)●|(% style="width:87px" %)0501 385 -|=(% style="width: 97px;" %)F5.02|(% style="width:320px" %)DI3 terminal function selection|(% style="width:196px" %)6|(% style="width:64px" %)●|(% style="width:87px" %)0502 386 -|=(% style="width: 97px;" %)F5.03|(% style="width:320px" %)DI4 terminal function selection|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0503 387 -|=(% style="width: 97px;" %)F5.04|(% style="width:320px" %)DI filter time|(% style="width:428px" %)0.000s~1.000s|(% style="width:196px" %)0.010s|(% style="width:64px" %)○|(% style="width:87px" %)0504 388 -|=(% style="width: 97px;" %)F5.05|(% style="width:320px" %)Terminal Command Option|(% style="width:428px" %)((( 389 -* 0: Two-line mode 1 390 -* 1: Two-line mode 2 391 -* 2: Three-line mode 1 392 -* 3: Three-line mode 2 393 -)))|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0505 394 -|=(% style="width: 97px;" %)F5.06|(% style="width:320px" %)UP/DOWN change rate range|(% style="width:428px" %)0.01Hz~50.00Hz|(% style="width:196px" %)0.50Hz|(% style="width:64px" %)○|(% style="width:87px" %)0506 395 -|=(% style="width: 97px;" %)F5.07|(% style="width:320px" %)AI minimum input|(% style="width:428px" %)0.00V~F5.09|(% style="width:196px" %)0.00V|(% style="width:64px" %)○|(% style="width:87px" %)0507 396 -|=(% style="width: 97px;" %)F5.08|(% style="width:320px" %)Percentage rate of AI minimum input|(% style="width:428px" %)-100.0%~+100.0%|(% style="width:196px" %)0.0%|(% style="width:64px" %)○|(% style="width:87px" %)0508 397 -|=(% style="width: 97px;" %)F5.09|(% style="width:320px" %)AI maximum input|(% style="width:428px" %)F5.07~+10.00V|(% style="width:196px" %)10.00V|(% style="width:64px" %)○|(% style="width:87px" %)0509 398 -|=(% style="width: 97px;" %)F5.10|(% style="width:320px" %)Percentage rate of AI maximum input|(% style="width:428px" %)-100.0%~+100.0%|(% style="width:196px" %)100.0%|(% style="width:64px" %)○|(% style="width:87px" %)050A 399 -|=(% style="width: 97px;" %)F5.11|(% style="width:320px" %)AI filter time|(% style="width:428px" %)0.00s~10.00s|(% style="width:196px" %)0.10s|(% style="width:64px" %)○|(% style="width:87px" %)050B 400 -|=(% style="width: 97px;" %)F5.12|(% style="width:320px" %)DI1 Enable Delay Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)050C 401 -|=(% style="width: 97px;" %)F5.13|(% style="width:320px" %)DI2 Enable Delay Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)050D 402 -|=(% style="width: 97px;" %)F5.14|(% style="width:320px" %)DI1 Disable Delay Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)050E 403 -|=(% style="width: 97px;" %)F5.15|(% style="width:320px" %)DI2 Disable Delay Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)050F 404 -|=(% style="width: 97px;" %)F5.16|(% style="width:320px" %)AI Input Digital Functional Option|(% style="width:428px" %)((( 405 -* 0: No function 406 -* 1: Forward running (FWD) 407 -* 2: Reverse running (REV) 408 -* 3: Three-wire operation control 409 -* 4: Forward point movement (FJOG) 410 -* 5: Reverse point movement (RJOG) 411 -* 6: Error Reset 412 -* 7: Terminal UP 413 -* 8: Terminal Down 414 -* 9: UP/DOWN Setting Clear 415 -* 10: External error input(Normally Open) 416 -* 11: PLC Status reset 417 -* 12: Multi stage speed terminal 1 418 -* 13: Multi stage speed terminal 2 419 -* 14: Reserved 420 -)))|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0510 421 -|=(% style="width: 97px;" %)F5.17|(% style="width:320px" %)AI Input Valid Level Option|(% style="width:428px" %)((( 422 -* 0: Low Level Valid 423 -* 1: High Level Valid 424 -)))|(% style="width:196px" %)1|(% style="width:64px" %)○|(% style="width:87px" %)0511 425 -|=(% style="width: 97px;" %)F6.00|(% style="width:320px" %)Relay Output Option|(% style="width:428px" %)((( 426 -* 0: No Output 427 -* 1: VFD Running 428 -* 2: Error Output(Output is valid only after VFD stops) 429 -* 3: Ready for Running 430 -* 4: Communication Setting 431 -* 5: User Defined Output 432 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0600 433 -|=(% style="width: 97px;" %)F6.01|(% style="width:320px" %)Relay1 Closed Delay Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)0601 434 -|=(% style="width: 97px;" %)F6.02|(% style="width:320px" %)Relay1 Open Delay Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)0602 435 -|=(% style="width: 97px;" %)F6.03|(% style="width:320px" %)((( 263 +“◎”:the parameter is the actual detected and recorded value which can’t be modified; 264 + 265 +Note: the communication address is hexadecimal. 266 + 267 + 268 +== 4.1 Functional parameter == 269 + 270 +|Parameter|Name|Setting Range|Default|Property|Address 271 +|F0.00|Reserved|Reserved|0|●|0000 272 +|F0.01|Command source selection|0:Operation panel control(LED off) 273 +1:Terminal control(LED on) 274 + 2:Communication LED (LED blinking)|0|●|0001 275 +|F0.02|Setting main frequency source X|0:Digital setting (non-retentive at power failure) 276 + 1:Digital setting (retentive at power failure) 277 + 2:Keypad Knob 278 + 3:AI 279 + 4:Multi-stage speed 280 + 5:Simple PLC 281 + 6:Communication|2|●|0002 282 +|F0.03|Keypad setting frequency|0.00Hz~F0.05|50.0Hz|○|0003 283 +|F0.04|Running direction selection|0:Forward 284 + 1:Reverse|0|○|0004 285 +|F0.05|Maximum Output Frequency|50.00Hz~400.00Hz|50.0Hz|●|0005 286 +|F0.06|Upper Limit of Frequency|F0.07~F0.05|50.0Hz|○|0006 287 +|F0.07|Lower Limit of Frequency|0.00Hz~F0.06|0.0Hz|○|0007 288 +|F0.08|The option of frequency lower limit|0:Running at frequency lower limit 289 +1:Stop 290 +2:Standby|0|○|0008 291 +|F0.09|Carrier Frequency|1kHz~6.0kHz|6.0kHz|●|0009 292 +|F0.10|Acceleration Time 1|0.0s~100.0s|10.0s|○|000A 293 +|F0.11|Deceleration Time 1|0.0s~100.0s|10.0s|○|000B 294 +|F0.12|Stop Mode|0:Decelerate to stop 295 + 1:Free stop|0|○|000C 296 +|F0.13|Retentive of digital setting frequency|0:No retentive 297 +1:retentive|1|●|000D 298 +|F0.14|Fan operating mode|0:Run when motor is running 299 + 1:Keep run when power on|0|○|000E 300 +|F0.15|AI1 Input Option|((( 301 +0:0-10V 302 + 303 +1:4-20mA 304 + 305 +2: 0-20mA 306 + 307 +3:0-5V 308 + 309 +4:0.5-4.5V 310 +)))|0|○|000F 311 +|F1.00|Default Setting Restoring|0:No Operation 312 + 1:Restore to factory default setting (not including F2 parameters) 313 + 2:Clear error records|0|●|0100 314 +|F1.01|Parameters Lockup|0:Invalid 315 + 1:Valid|0|○|0101 316 +|F1.02|User Password|0~65000|0|○|0102 317 +|F2.00|Motor Rated Power|0.1kW~2.2kW|Determined by Drive Model|●|0200 318 +|F2.01|Motor Rated Voltage|0-380V|Determined by Drive Model|●|0201 319 +|F2.02|Motor Rated Frequency|0- F0.05|Determined by Drive Model定|●|0202 320 +|F2.03|Motor Rated Current|1.00-10.00|Determined by Drive Model|●|0203 321 +|F2.05|Type of Motor|((( 322 +0:Single Phase 323 + 324 +1:Three Phase 325 +)))|0|●|0205 326 +|F2.06|Single-phase motor main and auxiliary winding turns ratio|10 ~ 200|80|○|0206 327 +|F2.07|Single-phase motor current correction factor|50 ~ 200|130|○|0207 328 +|F4.00|Torque Boost|0.0%~30.0%|4.0%|○|0400 329 +|F4.01|Cut-off frequency of torque boost|0.00Hz~F0.05|50.00Hz|●|0401 330 +|F4.02|Trigging frequency of DC braking at stop|0.00Hz~F0.05|0.00Hz|○|0402 331 +|F4.03|Delay time of DC braking at stop|0.0s~50.0s|0.0s|○|0403 332 +|F4.04|The current of DC braking at stop|0~100%|0|○|0404 333 +|F4.05|The time of DC braking at stop|0.0s~50.0s|0.0s|○|0405 334 +|F4.06|Automatic adjustment of carrier Frequency|0:Invalid; 1:Valid|0|●|0406 335 +|F4.07|0 frequency output option|0:Valid; 1:Invalid|1|●|0407 336 +|F5.00|DI1 terminal function selection|(% rowspan="4" %)((( 337 +0: No function 338 + 339 +1: Forward running (FWD) 340 + 341 +2: Reverse running (REV) 342 + 343 +3: Three-wire operation control 344 + 345 +4: Forward point movement (FJOG) 346 + 347 +5: Reverse point movement (RJOG) 348 +6:Error Reset 349 + 7:Terminal UP 350 + 8:Terminal Down 351 + 9:UP/DOWN Setting Clear 352 + 10:External error input(Normally Open) 353 + 11:PLC Status reset 354 + 12:Multi stage speed terminal 1 355 + 13: Multi stage speed terminal 2 356 + 14:Reserved 357 +)))|1|●|0500 358 +|F5.01|DI2 terminal function selection|2|●|0501 359 +|F5.02|DI3 terminal function selection|6|●|0502 360 +|F5.03|DI4 terminal function selection|0|●|0503 361 +|F5.04|DI filter time|0.000s~1.000s|0.010s|○|0504 362 +|F5.05|Terminal Command Option|0: Two-line mode 1 363 +1: Two-line mode 2 364 + 2: Three-line mode 1 365 +3: Three-line mode 2|0|●|0505 366 +|F5.06|UP/DOWN change rate range|0.01Hz~50.00Hz|0.50Hz|○|0506 367 +|F5.07|AI minimum input|0.00V~F5.09|0.00V|○|0507 368 +|F5.08|Percentage rate of AI minimum input|-100.0%~+100.0%|0.0%|○|0508 369 +|F5.09|AI maximum input|F5.07~+10.00V|10.00V|○|0509 370 +|F5.10|Percentage rate of AI maximum input|-100.0%~+100.0%|100.0%|○|050A 371 +|F5.11|AI filter time|0.00s~10.00s|0.10s|○|050B 372 +|F5.12|DI1 Enable Delay Time|0.0s~100.0s|0.0s|○|050C 373 +|F5.13|DI2 Enable Delay Time|0.0s~100.0s|0.0s|○|050D 374 +|F5.14|DI1 Disable Delay Time|0.0s~100.0s|0.0s|○|050E 375 +|F5.15|DI2 Disable Delay Time|0.0s~100.0s|0.0s|○|050F 376 +|F5.16|AI Input Digital Functional Option|((( 377 +0: No function 378 + 379 +1: Forward running (FWD) 380 + 381 +2: Reverse running (REV) 382 + 383 +3: Three-wire operation control 384 + 385 +4: Forward point movement (FJOG) 386 + 387 +5: Reverse point movement (RJOG) 388 +6:Error Reset 389 + 7:Terminal UP 390 + 8:Terminal Down 391 + 9:UP/DOWN Setting Clear 392 + 10:External error input(Normally Open) 393 + 11:PLC Status reset 394 + 12:Multi stage speed terminal 1 395 + 13: Multi stage speed terminal 2 396 + 14:Reserved 397 +)))|0|●|0510 398 +|F5.17|AI Input Valid Level Option|((( 399 +0:Low Level Valid 400 + 401 +1:High Level Valid 402 +)))|1|○|0511 403 +|F6.00|Relay Output Option|0:No Output 404 + 1:VFD Running 405 + 2:Error Output(Output is valid only after VFD stops) 406 + 3:Ready for Running 407 + 4:Communication Setting 408 + 5: User Defined Output|0|○|0600 409 +|F6.01|Relay1 Closed Delay Time|0.0s~100.0s|0.0s|○|0601 410 +|F6.02|Relay1 Open Delay Time|0.0s~100.0s|0.0s|○|0602 411 +|F6.03|((( 436 436 User defined output 437 437 438 438 Variability option(EX) 439 -)))|(% style="width:428px" %)((( 440 -* 0: Running Frequency 441 -* 1: Set Frequency 442 -* 2: Bus Voltage 443 -* 3: Output Voltage 444 -* 4: Output Current 445 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0603 446 -|=(% style="width: 97px;" %)F6.04|(% style="width:320px" %)User defined comparison method|(% style="width:428px" %)Units digit:comparison test method((( 447 -* 0: Equal (EX==X1) 448 -* 1: Equal or greater than 449 -* 2: Equal or less than 450 -* 3: Interval comparison (X1≤EX≤X2) 451 -* 4: Units digit test (EX&X1=X2) 452 - 415 +)))|0:Running Frequency 416 + 1:Set Frequency 417 + 2:Bus Voltage 418 + 3:Output Voltage 419 + 4:Output Current|0|○|0603 420 +|F6.04|User defined comparison method|Units digit:comparison test method 421 +0: Equal (EX==X1) 422 +1: Equal or greater than 423 +2: Equal or less than 424 +3 Interval comparison (X1≤EX≤X2) 425 +4:Units digit test (EX&X1=X2) 453 453 Tens digit: output method 454 - 455 -* 0: False value output 456 -* 1: Real value output 457 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0604 458 -|=(% style="width: 97px;" %)F6.05|(% style="width:320px" %)User defined output dead zone|(% style="width:428px" %)0~65535|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0605 459 -|=(% style="width: 97px;" %)F6.06|(% style="width:320px" %)((( 427 + 0: False value output 428 +1: Real value output|0|○|0604 429 +|F6.05|User defined output dead zone|0~65535|0|○|0605 430 +|F6.06|((( 460 460 User-defined output 461 461 462 462 comparison value 1 463 -)))| (% style="width:428px" %)0~65535|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0606464 -| =(% style="width: 97px;" %)F6.07|(% style="width:320px" %)(((434 +)))|0~65535|0|○|0606 435 +|F6.07|((( 465 465 User-defined output 466 466 467 467 comparison value 2 468 -)))|(% style="width:428px" %)0~65535|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0607 469 -|=(% style="width: 97px;" %)F6.08|(% style="width:320px" %)AO1 Output Option|(% rowspan="2" style="width:428px" %)((( 470 -* 0: Running Frequency(0~F0.05) 471 -* 1: Set Frequency(0~F0.05) 472 -* 2: Output Current(0~Double Rated Current of VFD) 473 -* 3: Output Voltage(0~1.2times of VFD Rated Output Voltage) 474 -* 4: AI(0~10V) 475 -* 5: Bus Voltage(0~500.0/1000.0V) 476 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0608 477 -|=(% style="width: 97px;" %)F6.09|(% style="width:320px" %)AO2 Output Option|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0609 478 -|=(% style="width: 97px;" %)F6.10|(% style="width:320px" %)AO1 offset coefficient|(% style="width:428px" %)-100.0%~+100.0%|(% style="width:196px" %)0.0%|(% style="width:64px" %)○|(% style="width:87px" %)060A 479 -|=(% style="width: 97px;" %)F6.11|(% style="width:320px" %)AO1 gain|(% style="width:428px" %)-10.00~+10.00|(% style="width:196px" %)1.00|(% style="width:64px" %)○|(% style="width:87px" %)060B 480 -|=(% style="width: 97px;" %)F6.12|(% style="width:320px" %)AO2 offset coefficient|(% style="width:428px" %)-100.0%~+100.0%|(% style="width:196px" %)0.0%|(% style="width:64px" %)○|(% style="width:87px" %)060C 481 -|=(% style="width: 97px;" %)F6.13|(% style="width:320px" %)AO2 offset coefficient|(% style="width:428px" %)-10.00~+10.00|(% style="width:196px" %)1.00|(% style="width:64px" %)○|(% style="width:87px" %)060D 482 -|=(% style="width: 97px;" %)F7.00|(% style="width:320px" %)Reserved|(% style="width:428px" %)Reserved|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0700 483 -|=(% style="width: 97px;" %)F7.01|(% style="width:320px" %)STOP Button Function|(% style="width:428px" %)((( 484 -* 0: Valid only at keypad control mode 485 -* 1: Valid at all control modes 486 -)))|(% style="width:196px" %)1|(% style="width:64px" %)○|(% style="width:87px" %)0701 487 -|=(% style="width: 97px;" %)F7.02|(% style="width:320px" %)LED display parameters at running status|(% rowspan="2" style="width:428px" %)((( 488 -* Bit0: Running Frequency(Hz) 489 -* Bit1: Set Frequency(Hz) 490 -* Bit2: Bus Voltage(V) 491 -* Bit3: Output Voltage(V) 492 -* Bit4: Output Current(A) 493 -* Bit5: DI Input Status 494 -* Bit6: DO Output Status 495 -* Bit7: Keypad Knob Voltage(V) 496 -* Bit8: AIVoltage(V) 497 -* Bit9: Load Speed 498 -* Bit10: PID Set Value 499 -* Bit11: PID Feedback Value 500 -* Bit12: PLC Stage 501 -* Bit13: Feedback Frequency(Unit:0.1Hz) 502 -* Bit14: Communication Set Value 503 -* Bit15: Main Frequency Source X 504 -)))|(% style="width:196px" %)0x1F|(% style="width:64px" %)○|(% style="width:87px" %)0702 505 -|=(% style="width: 97px;" %)F7.03|(% style="width:320px" %)LED display parameters at stop status|(% style="width:196px" %)0x06|(% style="width:64px" %)○|(% style="width:87px" %)0703 506 -|=(% style="width: 97px;" %)F7.04|(% style="width:320px" %)Load speed display coefficient|(% style="width:428px" %)0.0001~6.5000|(% style="width:196px" %)3.000|(% style="width:64px" %)○|(% style="width:87px" %)0704 507 -|=(% style="width: 97px;" %)F7.05|(% style="width:320px" %)Software Version|(% style="width:428px" %)-|(% style="width:196px" %)-|(% style="width:64px" %)◎|(% style="width:87px" %)0705 508 -|=(% style="width: 97px;" %)F8.00|(% style="width:320px" %)Jog Running Frequency|(% style="width:428px" %)0.00Hz~F0.05|(% style="width:196px" %)2.00Hz|(% style="width:64px" %)○|(% style="width:87px" %)0800 509 -|=(% style="width: 97px;" %)F8.01|(% style="width:320px" %)Jog Acceleration Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)10.0s|(% style="width:64px" %)○|(% style="width:87px" %)0801 510 -|=(% style="width: 97px;" %)F8.02|(% style="width:320px" %)Jog Deceleration Time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)10.0s|(% style="width:64px" %)○|(% style="width:87px" %)0802 511 -|=(% style="width: 97px;" %)F8.03|(% style="width:320px" %)FWD/REV dead zone time|(% style="width:428px" %)0.0s~100.0s|(% style="width:196px" %)0.0s|(% style="width:64px" %)○|(% style="width:87px" %)0803 512 -|=(% style="width: 97px;" %)F8.04|(% style="width:320px" %)Reverse control|(% style="width:428px" %)((( 513 -* 0: valid 514 -* 1: invalid 515 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0804 516 -|=(% style="width: 97px;" %)F8.05|(% style="width:320px" %)Reserved|(% style="width:428px" %)0|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0805 517 -|=(% style="width: 97px;" %)F8.06|(% style="width:320px" %)Startup Protection Option|(% style="width:428px" %)((( 518 -* 0:Invalid 519 -* 1:Valid 520 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0806 521 -|=(% style="width: 97px;" %)F8.07|(% style="width:320px" %)Terminal jogging priority|(% style="width:428px" %)((( 522 -* 0: Invalid 523 -* 1: Valid 524 -)))|(% style="width:196px" %)1|(% style="width:64px" %)○|(% style="width:87px" %)0807 525 -|=(% style="width: 97px;" %)FC.00|(% style="width:320px" %)Local Addresse|(% style="width:428px" %)1~30,0 for broadcast addresse|(% style="width:196px" %)1|(% style="width:64px" %)○|(% style="width:87px" %)0C00 526 -|=(% style="width: 97px;" %)FC.01|(% style="width:320px" %)Baud Rate|(% style="width:428px" %)((( 527 -* 0: 4800bPS 528 -* 1: 9600bPS 529 -* 2: 19200bPS 530 -)))|(% style="width:196px" %)1|(% style="width:64px" %)○|(% style="width:87px" %)0C01 531 -|=(% style="width: 97px;" %)FC.02|(% style="width:320px" %)Data format|(% style="width:428px" %)((( 532 -* 0: No check, data format (8.N.1) 533 -* 1: Odd Parity check, data format (8.O.1) 534 -* 2: Even parity check, data format (8.E.1) 535 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0C02 536 -|=(% style="width: 97px;" %)FC.03|(% style="width:320px" %)Respond Delay|(% style="width:428px" %)0ms~20ms|(% style="width:196px" %)2|(% style="width:64px" %)○|(% style="width:87px" %)0C03 537 -|=(% style="width: 97px;" %)FC.04|(% style="width:320px" %)Reserved|(% style="width:428px" %)0|(% style="width:196px" %)0|(% style="width:64px" %)●|(% style="width:87px" %)0C04 538 -|=(% style="width: 97px;" %)FD.00|(% style="width:320px" %)Multistage speed 0|(% style="width:428px" %)-100.0%~100.0%(100.0% as F0.05)|(% style="width:196px" %)0.00%|(% style="width:64px" %)○|(% style="width:87px" %)0D00 539 -|=(% style="width: 97px;" %)FD.01|(% style="width:320px" %)Multistage speed 1|(% style="width:428px" %)-100.0%~100.0%|(% style="width:196px" %)0.00%|(% style="width:64px" %)○|(% style="width:87px" %)0D01 540 -|=(% style="width: 97px;" %)FD.02|(% style="width:320px" %)Multistage speed 2|(% style="width:428px" %)-100.0%~100.0%|(% style="width:196px" %)0.00%|(% style="width:64px" %)○|(% style="width:87px" %)0D02 541 -|=(% style="width: 97px;" %)FD.03|(% style="width:320px" %)Multistage speed 3|(% style="width:428px" %)-100.0%~100.0%|(% style="width:196px" %)0.00%|(% style="width:64px" %)○|(% style="width:87px" %)0D03 542 -|=(% style="width: 97px;" %)FD.04|(% style="width:320px" %)Simple PLC running mode|(% style="width:428px" %)((( 543 -* 0: Stop after the AC Drive runs one cycle 544 -* 1: Keep final values after the AC Drive runs one cycle 545 -* 2: Repeat after the AC Drive runs one cycle 546 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D04 547 -|=(% style="width: 97px;" %)FD.05|(% style="width:320px" %)Simple PLC retentive option|(% style="width:428px" %)Units Digit: Reserved 548 -Tens Digit:((( 549 -* 0: Invalid 550 -* 1: Valid 551 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D05 552 -|=(% style="width: 97px;" %)FD.06|(% style="width:320px" %)Running time of simple PLC reference 0|(% style="width:428px" %)0.0s(h)~100.0s(h)|(% style="width:196px" %)0.0s(h)|(% style="width:64px" %)○|(% style="width:87px" %)0D06 553 -|=(% style="width: 97px;" %)FD.07|(% style="width:320px" %)Acceleration/deceleration time of simple PLC reference 0|(% style="width:428px" %)0~3|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D07 554 -|=(% style="width: 97px;" %)FD.08|(% style="width:320px" %)Running time of simple PLC reference 1|(% style="width:428px" %)0.0~100.0|(% style="width:196px" %)0.0s(h)|(% style="width:64px" %)○|(% style="width:87px" %)0D08 555 -|=(% style="width: 97px;" %)FD.09|(% style="width:320px" %)Acceleration/deceleration time of simple PLC reference 1|(% style="width:428px" %)0~~3|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D09 556 -|=(% style="width: 97px;" %)FD.10|(% style="width:320px" %)Running time of simple PLC reference 2|(% style="width:428px" %)0.0 ~~100.0|(% style="width:196px" %)0.0s(h)|(% style="width:64px" %)○|(% style="width:87px" %)0D0A 557 -|=(% style="width: 97px;" %)FD.11|(% style="width:320px" %)Acceleration/deceleration time of simple PLC reference 2|(% style="width:428px" %)0~~3|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D0B 558 -|=(% style="width: 97px;" %)FD.12|(% style="width:320px" %)Running time of simple PLC reference 3|(% style="width:428px" %)0.0~~100.0|(% style="width:196px" %)0.0s(h)|(% style="width:64px" %)○|(% style="width:87px" %)0D0C 559 -|=(% style="width: 97px;" %)FD.13|(% style="width:320px" %)Acceleration/deceleration time of simple PLC reference 3|(% style="width:428px" %)0~~3|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D0D 560 -|=(% style="width: 97px;" %)FD.14|(% style="width:320px" %)Time unit of simple PLC running|(% style="width:428px" %)((( 561 -* 0: s(second) 562 -* 1: h(hour) 563 -* 2: min(minute) 564 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D0E 565 -|=(% style="width: 97px;" %)FD.15|(% style="width:320px" %)The source of multistage speed 0|(% style="width:428px" %)((( 566 -* 0: Set by FD.00 567 -* 1: AI 568 -)))|(% style="width:196px" %)0|(% style="width:64px" %)○|(% style="width:87px" %)0D0F 439 +)))|0~65535|0|○|0607 440 +|F6.08|AO1 Output Option|(% rowspan="2" %)0:Running Frequency(0~F0.05) 441 + 1:Set Frequency(0~F0.05) 442 + 2:Output Current(0~Double Rated Current of VFD) 443 + 3:Output Voltage(0~1.2times of VFD Rated Output Voltage) 444 + 4:AI(0~10V) 445 + 5:Bus Voltage(0~500.0/1000.0V)|0|○|0608 446 +|F6.09|AO2 Output Option|0|○|0609 447 +|F6.10|AO1 offset coefficient|-100.0%~+100.0%|0.0%|○|060A 448 +|F6.11|AO1 gain|-10.00~+10.00|1.00|○|060B 449 +|F6.12|AO2 offset coefficient|-100.0%~+100.0%|0.0%|○|060C 450 +|F6.13|AO2 offset coefficient|-10.00~+10.00|1.00|○|060D 451 +|F7.00|Reserved|Reserved|0|○|0700 452 +|F7.01|STOP Button Function|0:Valid only at keypad control mode 453 + 1:Valid at all control modes|1|○|0701 454 +|F7.02|LED display parameters at running status|(% rowspan="2" %)((( 455 +Bit0:Running Frequency(Hz) 456 + Bit1:Set Frequency(Hz) 457 + Bit2:Bus Voltage(V) 458 + Bit3:Output Voltage(V) 459 + Bit4:Output Current(A) 460 + Bit5:DI Input Status 461 + Bit6:DO Output Status 462 + Bit7:Keypad Knob Voltage(V) 569 569 570 -== Monitoring Parameters == 464 +Bit8:AIVoltage(V) 465 + Bit9:Load Speed 466 + Bit10:PID Set Value 467 + Bit11:PID Feedback Value 468 + Bit12:PLC Stage 469 + Bit13:Feedback Frequency(Unit:0.1Hz) 571 571 471 +Bit14:Communication Set Value 472 + Bit15:Main Frequency Source X 473 +)))|0x1F|○|0702 474 +|F7.03|LED display parameters at stop status|0x06|○|0703 475 +|F7.04|Load speed display coefficient|0.0001~6.5000|3.000|○|0704 476 +|F7.05|Software Version|-|-|◎|0705 477 +|F8.00|Jog Running Frequency|0.00Hz~F0.05|2.00Hz|○|0800 478 +|F8.01|Jog Acceleration Time|0.0s~100.0s|10.0s|○|0801 479 +|F8.02|Jog Deceleration Time|0.0s~100.0s|10.0s|○|0802 480 +|F8.03|FWD/REV dead zone time|0.0s~100.0s|0.0s|○|0803 481 +|F8.04|Reverse control|((( 482 +0:valid 483 + 484 +1:invalid 485 +)))|0|○|0804 486 +|F8.05|Reserved|0|0|●|0805 487 +|F8.06|Startup Protection Option|0:Invalid 488 + 1:Valid|0|○|0806 489 +|F8.07|Terminal jogging priority|0:Invalid 1:Valid|1|○|0807 490 +|FC.00|Local Addresse|1~30,0 for broadcast addresse|1|○|0C00 491 +|FC.01|Baud Rate|0:4800bPS 492 + 1:9600bPS 493 + 2:19200bPS|1|○|0C01 494 +|FC.02|Data format|0:No check, data format (8.N.1) 495 + 1:Odd Parity check, data format (8.O.1) 496 + 2:Even parity check, data format (8.E.1)|0|○|0C02 497 +|FC.03|Respond Delay|0ms~20ms|2|○|0C03 498 +|FC.04|Reserved|0|0|●|0C04 499 +|FD.00|Multistage speed 0|-100.0%~100.0%(100.0% as F0.05)|0.00%|○|0D00 500 +|FD.01|Multistage speed 1|-100.0%~100.0%|0.00%|○|0D01 501 +|FD.02|Multistage speed 2|-100.0%~100.0%|0.00%|○|0D02 502 +|FD.03|Multistage speed 3|-100.0%~100.0%|0.00%|○|0D03 503 +|FD.04|Simple PLC running mode|((( 504 +0:Stop after the AC Drive runs one cycle 505 + 506 +1:Keep final values after the AC Drive runs one cycle 507 + 508 +2:Repeat after the AC Drive runs one cycle 509 +)))|0|○|0D04 510 +|FD.05|Simple PLC retentive option|Units Digit:Reserved 511 + Tens Digit: 512 + 0:Invalid 513 + 1:Valid|0|○|0D05 514 +|FD.06|Running time of simple PLC reference 0|0.0s(h)~100.0s(h)|0.0s(h)|○|0D06 515 +|FD.07|Acceleration/deceleration time of simple PLC reference 0|0~3|0|○|0D07 516 +|FD.08|Running time of simple PLC reference 1|0.0 ~ 100.0|0.0s(h)|○|0D08 517 +|FD.09|Acceleration/deceleration time of simple PLC reference 1|0 ~ 3|0|○|0D09 518 +|FD.10|Running time of simple PLC reference 2|0.0 ~ 100.0|0.0s(h)|○|0D0A 519 +|FD.11|Acceleration/deceleration time of simple PLC reference 2|0 ~ 3|0|○|0D0B 520 +|FD.12|Running time of simple PLC reference 3|0.0 ~ 100.0|0.0s(h)|○|0D0C 521 +|FD.13|Acceleration/deceleration time of simple PLC reference 3|0 ~ 3|0|○|0D0D 522 +|FD.14|Time unit of simple PLC running|0:s(second) 523 + 1:h(hour) 524 + 2:min(minute)|0|○|0D0E 525 +|FD.15|The source of multistage speed 0|((( 526 +0:Set by FD.00 527 + 528 +1:AI 529 +)))|0|○|0D0F 530 + 531 +== 4.2 Monitoring Parameters == 532 + 572 572 |Parameter|Name|Minimum Unit|Priority|Address 573 573 |D0.00|Running Frequency(Hz)|0.01Hz|◎|D000 574 574 |D0.01|Set Frequency(Hz)|0.01Hz|◎|D001 ... ... @@ -584,7 +584,7 @@ 584 584 |D0.13|PLC Stage|1|◎|D013 585 585 |D0.14|Feedback Speed(Unit0.1Hz)|0.1Hz|◎|D014 586 586 587 -== Error Records == 548 +== 4.3 Error Records == 588 588 589 589 |Parameter|Name|Range and Description|Priority|Address 590 590 |E0.00|Latest error type|No Error:0 ... ... @@ -614,11 +614,11 @@ 614 614 |E1.04|Input terminals status at former error|0-63|●| E104 615 615 |E1.05|IGBT temperature at former error|0-65535|●| E105 616 616 617 -= 7Communication Protocol =578 += Chapter5 Communication Protocol = 618 618 619 619 VM Series AC Drive provides RS485 communication interface and supports Modbus communication protocol. Users can achieve centralized control by computer or PLC, set AC Drive operation commands, modify or read function code parameters, read the working state and fault info of the AC Drive. 620 620 621 -== Communication Control Address == 582 +== 5.1 Communication Control Address == 622 622 623 623 |Function|Address|Description|Remarks|Characteristic 624 624 |Communication Set Value|1000H|-10000~10000(with ± sign)|F0.05*(±100.00%)|R/W ... ... @@ -669,7 +669,7 @@ 669 669 670 670 Sheet 5-1-1 Control Command Addresses 671 671 672 -== EEPROM Addresses Introduction == 633 +== 5.2 EEPROM Addresses Introduction == 673 673 674 674 The addresses listed in the sheet above is the way of writing RAM. The RAM stores the data after power-off and does not save it. In the communication mode, for the write command "06H", if the parameter needs to be stored after power-off, the method of writing EEPROM should be used. The original "0" of the most significant bit of the RAM address is changed to "F", which is converted into the corresponding EEPROM address, for example: "0XXX" is changed to "FXXX" 675 675 ... ... @@ -681,9 +681,9 @@ 681 681 682 682 It should be noted that the erasing life of EEPROM is about 1 million times. After exceeding the erasing times, it will affect the reliability of data storage. If it is not necessary, it is recommended to control the communication by writing to RAM. 683 683 684 -= 8Troubleshooting & countermeasures =645 += Chapter 6 Troubleshooting & countermeasures = 685 685 686 -== Faults and solutions == 647 +== 6.1 Faults and solutions == 687 687 688 688 |Fault code|Fault type|Reason|Solution 689 689 |Err02|Overcurrent during acceleration|((( ... ... @@ -836,8 +836,9 @@ 836 836 837 837 Table 6-1-1 Faults and solutions 838 838 839 -== Common faults and solutions == 840 840 801 +== 6.2 Common faults and solutions == 802 + 841 841 |**SN**|**Fault**|**Possible causes**|**Solutions** 842 842 |1|No display at power-on state|((( 843 843 ~1. The input power of AC Drive is abnormal. ... ... @@ -919,3 +919,10 @@ 919 919 ))) 920 920 921 921 Table 6-2-1 Common faults and solutions 884 + 885 + 886 +((( 887 + 888 +))) 889 + 890 +