Changes for page Servo Showing Err. 23?
Last modified by Jiahao Lai on 2026/01/16 10:13
From version 2.1
edited by Parth Makwana
on 2025/11/25 14:09
on 2025/11/25 14:09
Change comment:
There is no comment for this version
To version 3.1
edited by Parth Makwana
on 2025/11/25 14:09
on 2025/11/25 14:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,4 +7,13 @@ 7 7 8 8 9 9 10 - 10 +Troubleshooting 11 + 12 +|=**Reason**|=**Troubleshooting methods**|=**Handling** 13 +|Internal brake resistance wiring error|Check whether C, D are connected to the short cap and the contact is normal|When using an internal braking resistor, reliably connect the shorting cap or shorting wire between C and D 14 +|External braking resistor wiring error|Check whether the external resistor is connected reliably between P+ and C.|When using an external braking resistor, the external resistor is reliably strung between P+ and C 15 +|**Internal braking resistor damaged**|**The servo drive is powered off. Detects whether the resistance between P+ and D is 50Ω**|((( 16 +Contact the technician to replace the internal braking resistor. 17 + 18 +Use an external braking resistor and change the relevant parameters of the P00 "Basic Settings". 19 +)))