Servo Showing Err. 23?

Version 3.1 by Parth Makwana on 2025/11/25 14:09

Why the servo is showing Err. 23? 

1764050915292-784.png

Troubleshooting

ReasonTroubleshooting methodsHandling
Internal brake resistance wiring errorCheck whether C, D are connected to the short cap and the contact is normalWhen using an internal braking resistor, reliably connect the shorting cap or shorting wire between C and D
External braking resistor wiring errorCheck whether the external resistor is connected reliably between P+ and C.When using an external braking resistor, the external resistor is reliably strung between P+ and C
Internal braking resistor damagedThe servo drive is powered off. Detects whether the resistance between P+ and D is 50Ω

Contact the technician to replace the internal braking resistor.

Use an external braking resistor and change the relevant parameters of the  P00 "Basic Settings".