... ... @@ -591,7 +591,7 @@
591 591  
592 592  **[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]**
593 593  
594 -= **User permission** =
594 += **{{id name="_Toc3497"/}}{{id name="_User_Permission"/}}User Permission** =
595 595  
596 596  **Introduction**
597 597  
... ... @@ -600,14 +600,11 @@
600 600  1. Operating record: it records user operations information, the records files are saved in HMI flash; its path is [~\~\flash~\~\UserOperationLogs.db].
601 601  1. When it is on simulator mode, the files are saved in C disk, its path is [C:~\~\WECON\UserMgrFile\UserOperationLogs.db].
602 602  
603 -(% class="box infomessage" %)
604 -(((
605 605  ✎**Note: **The user name and password must be unique.
606 -)))
607 607  
608 -== Settings ==
605 +== **Settings** ==
609 609  
610 -Open PIStudio software, then operate as the following figure.
607 +**Open PIStudio software, then operate as the following figure.**
611 611  
612 612  (% style="text-align:center" %)
613 613  [[image:用户权限 1.png||class="img-thumbnail"]]
... ... @@ -626,26 +626,25 @@
626 626  * When the configured file does not have the administrator account, a new user can be added  through "Funtion address" and set as the administrator.
627 627  * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in.
628 628  
629 -== Object permission configuration ==
626 +== **Object permission configuration** ==
630 630  
631 631  (% style="text-align:center" %)
632 632  [[image:用户权限 2.png||class="img-thumbnail"]]
633 633  
634 -**Operation Procedure of Object Permission**
631 +{{id name="OLE_LINK3"/}}{{id name="OLE_LINK4"/}}**Operation Procedure of Object Permission**
635 635  
636 636  1. Open the object setting windows;
637 -1. Select "Security" windows;
638 -1. Check the "User Permission";
639 -1. Select "Level" to set permission level;
640 -1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded;
641 -1. Select the "[[Access Denied Setting>>path:#_Security]]" mode;
634 +1. Select [Security] windows;
635 +1. Check the [User Permission];
636 +1. Select [Level] to set permission level;
637 +1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;
638 +1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode;
642 642  
643 643  **Log information description**
644 644  
645 -A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
642 +1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
643 +1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
646 646  
647 -The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
648 -
649 649   The data format are as follows.
650 650  
651 651  (% class="table-bordered" %)
... ... @@ -661,7 +661,8 @@
661 661  |W|Single word
662 662  |D|Double word
663 663  
664 -Examples.
660 +(% start="3" %)
661 +1. Examples.
665 665  
666 666  * Unsigned decimal, BCD, 32-bit float and Signed decimal are as follows.
667 667  
... ... @@ -784,7 +784,7 @@
784 784  
785 785  [[https:~~/~~/drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq>>url:https://drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq]]
786 786  
787 -= Message prompt =
784 += **{{id name="_Toc29015"/}}{{id name="_MessagePrompt"/}}Message Prompt** =
788 788  
789 789  A message box is a window used to show some prompts or warnings to users. For example, the application process a task in the process of pop-up message box, suggesting that "U disk has been detected", then the customer can carry out data dump function.
790 790  
... ... @@ -851,10 +851,12 @@
851 851  
852 852  For example:
853 853  
854 -* In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
855 -* For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
856 -* For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
851 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
857 857  
853 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
854 +
855 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
856 +
858 858  **(2) Server Selection**
859 859  