Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -180,26 +180,23 @@ 180 180 181 181 * **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object); 182 182 ** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters; 183 -* **Group: ** Itsets thegroups'initial number of recipe;183 +* **Group: **Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places. 184 184 * **Elements:** It sets members' initial number of each group; 185 185 * **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form; 186 186 * **Decimal: **It sets integer and scale digits; 187 187 188 -**Mode Selection** 188 +**Mode Selection: **Select Simple or Advanced mode. Recipe file is divided into simple mode and advanced mode. Only in advanced mode can exist multiple recipe files used at the same time. (used wiht file list onject), Simple mode can only support a recipe file; Aadvanced mode can insert group information and reordered. 189 189 190 - UserscouldselectSimple orAdvancedmode.190 +Function address: all operations are done through function addresses, different operating value is as follows: 191 191 192 -**Function Address:** 192 +* = 0: no operation; 193 +* = 1: trigger read data; 194 +* = 2: new trigger or update (If there is group number, it updates.) 195 +* = 4: insert (only valid in advanced mode) 196 +* = 8: delete (Delete according to the writing group number. If write and read address are consistent, refer to the reading group number); 197 +* = 16: delete and sorted ((Delete according to the writing group number. If write and read address are consistent, refer to the reading group number) 198 +* = 64: import CSV recipe file. 193 193 194 -All the operations for recipe is by this address 195 - 196 -* =0 No operation. 197 -* =1 Read data from recipe. 198 -* =2 Insert a new group or write data to exist group. 199 -* =4 Inserted (only advanced mode). 200 -* =8 Delete. 201 -* =16 Delete and Sequence. 202 - 203 203 **Use Multiple File** 204 204 205 205 Check it to use more than one recipe file in HMI, but this option only valid in [Advanced mode]; ... ... @@ -244,27 +244,8 @@ 244 244 **✎Note: **This function only supported in HMI+, i series, ie series, ig series. 245 245 ))) 246 246 247 -** OperatingProcedures**244 +**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 248 248 249 -* Click "Project"→"Bit Alarm" as below shows. 250 - 251 -(% style="text-align:center" %) 252 -[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]] 253 - 254 -* Click "Add" button to open "Recipe" setting window. 255 - 256 -(% style="text-align:center" %) 257 -[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]] 258 - 259 -* Set basic settings for recipe. 260 -* Select mode according to actual condition. 261 -* Other settings can be set according to the actual situation. 262 -* Click "OK“ button to complete settings. 263 - 264 -**Recipe Demo Download Link** 265 - 266 -[[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 267 - 268 268 = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) = 269 269 270 270 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC. ... ... @@ -421,7 +421,7 @@ 421 421 422 422 Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen. 423 423 424 -Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/ wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object.402 +Recipe function settings will be display in "[[History XY Plot>>path:https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object. 425 425 426 426 (% style="text-align:center" %) 427 427 [[image:历史XY 2.png||class="img-thumbnail"]] ... ... @@ -582,15 +582,8 @@ 582 582 * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ". 583 583 * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled. 584 584 585 -You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/ wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]"563 +You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]" 586 586 587 -(% class="wikigeneratedid" id="H" %) 588 -**PI Data Record Demo Download** 589 - 590 -**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 591 - 592 -**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 593 - 594 594 = **User permission** = 595 595 596 596 **Introduction** ... ... @@ -638,7 +638,7 @@ 638 638 1. Check the "User Permission"; 639 639 1. Select "Level" to set permission level; 640 640 1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded; 641 -1. Select the " [[Access Denied Setting>>path:#_Security]]" mode;612 +1. Select the "Access Denied Setting" mode; 642 642 643 643 **Log information description** 644 644
- image-20220805170000-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 KB - Content
- image-20220805170046-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.5 KB - Content
- image-20220805170102-3.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.3 KB - Content
- image-20220805170147-4.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.3 KB - Content
- image-20220805170232-5.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.3 KB - Content