Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -244,47 +244,27 @@ 244 244 **✎Note: **This function only supported in HMI+, i series, ie series, ig series. 245 245 ))) 246 246 247 - == Simple recipe==247 +**Operating Procedures** 248 248 249 - Therecipe functionshould beusedtogether withthe recipe configuration area,file listand recorddisplayobject.249 +* Click "Project"→"Bit Alarm" as below shows. 250 250 251 -* Click the button [[image:image-20220805170000-1.jpeg]] in "Project"→"Bit Alarm" as below shows. 251 +(% style="text-align:center" %) 252 +[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]] 252 252 253 - [[image:image-20220805170046-2.jpeg]]254 +* Click "Add" button to open "Recipe" setting window. 254 254 255 -* Click "Add" button to open "Recipe" setting window. The recipe mode is divided into simple mode and advanced mode, and you could choose the most suitable mode for configuration according to your needs. The simple mode is as below. 256 +(% style="text-align:center" %) 257 +[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]] 256 256 257 -[[image:image-20220805170102-3.jpeg]] 259 +* Set basic settings for recipe. 260 +* Select mode according to actual condition. 261 +* Other settings can be set according to the actual situation. 262 +* Click "OK“ button to complete settings. 258 258 259 -**Recipe folder: **set the nameofthe currentrecipe file.264 +**Recipe Demo Download Link** 260 260 261 - **Group(0~~1000):** Set thereciperoup number, the numberof elements, the data format.The data format has 8 modes: 16-bit signed decimal, 16-bit unsigneddecimal,16-bit BCD, 32-bitsigned decimal, 32-bitunsigned decimal, 16-bitBCD, 32-bitfloatingpoint number, 64-bit (double-precision) floating-point number, string, and the choice ofdataintegerand decimal places.266 +[[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 262 262 263 -(% class="box infomessage" %) 264 -((( 265 -✎**Note: **data format is set for the recipe elements, and all the elements in a recipe data format is the same. 266 -))) 267 - 268 -**Mode: **Recipe file is divided into simple mode and advanced mode. Only in advanced mode can exist multiple recipe files used at the same time. (used wiht file list onject), Simple mode can only support a recipe file; Aadvanced mode can insert group information and reordered. 269 - 270 -Function address: all operations are done through function addresses, different operating value is as follows: 271 - 272 -* = 0: no operation; 273 -* = 1: trigger read data; 274 -* = 2: new trigger or update (If there is group number, it updates.) 275 -* = 4: insert (only valid in advanced mode) 276 -* = 8: delete (Delete according to the writing group number. If write and read address are consistent, refer to the reading group number); 277 -* = 16: delete and sorted ((Delete according to the writing group number. If write and read address are consistent, refer to the reading group number) 278 -* = 64: import CSV recipe file. 279 - 280 -Recipe folder names can only consist of (0~~9), (a~~z), (A~~Z), ('_') (''), and other non-English characters. 281 - 282 -Adcanced 283 - 284 -**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 285 - 286 - 287 - 288 288 = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) = 289 289 290 290 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC. ... ... @@ -441,7 +441,7 @@ 441 441 442 442 Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen. 443 443 444 -Recipe function settings will be display in "[[History XY Plot>>path:http s://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object.424 +Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object. 445 445 446 446 (% style="text-align:center" %) 447 447 [[image:历史XY 2.png||class="img-thumbnail"]] ... ... @@ -602,8 +602,15 @@ 602 602 * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ". 603 603 * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled. 604 604 605 -You could click here to jump to object "[[Data Record Display>>http s://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]"585 +You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]" 606 606 587 +(% class="wikigeneratedid" id="H" %) 588 +**PI Data Record Demo Download** 589 + 590 +**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 591 + 592 +**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 593 + 607 607 = **User permission** = 608 608 609 609 **Introduction** ... ... @@ -651,7 +651,7 @@ 651 651 1. Check the "User Permission"; 652 652 1. Select "Level" to set permission level; 653 653 1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded; 654 -1. Select the "Access Denied Setting" mode; 641 +1. Select the "[[Access Denied Setting>>path:#_Security]]" mode; 655 655 656 656 **Log information description** 657 657
- image-20220805170000-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.1 KB - Content
- image-20220805170046-2.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.5 KB - Content
- image-20220805170102-3.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.3 KB - Content
- image-20220805170147-4.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.3 KB - Content
- image-20220805170232-5.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.3 KB - Content