Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 21.4
edited by Stone Wu
on 2022/08/05 17:28
Change comment: There is no comment for this version
To version 20.1
edited by Stone Wu
on 2022/08/02 11:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -180,23 +180,26 @@
180 180  
181 181  * **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object);
182 182  ** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters;
183 -* **Group: **Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places.
183 +* **Group: **It sets the groups' initial number of recipe;
184 184  * **Elements:** It sets members' initial number of each group;
185 185  * **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form;
186 186  * **Decimal: **It sets integer and scale digits;
187 187  
188 -**Mode Selection: **Select Simple or Advanced mode. Recipe file is divided into simple mode and advanced mode. Only in advanced mode can exist multiple recipe files used at the same time. (used wiht file list onject), Simple mode can only support a recipe file; Aadvanced mode can insert group information and reordered.
188 +**Mode Selection**
189 189  
190 -Function address: all operations are done through function addresses, different operating value is as follows:
190 +Users could select Simple or Advanced mode.
191 191  
192 -* = 0: no operation;
193 -* = 1: trigger read data;
194 -* = 2: new trigger or update (If there is group number, it updates.)
195 -* = 4: insert (only valid in advanced mode)
196 -* = 8: delete (Delete according to the writing group number. If write and read address are consistent, refer to the reading group number);
197 -* = 16: delete and sorted ((Delete according to the writing group number. If write and read address are consistent, refer to the reading group number)
198 -* = 64: import CSV recipe file.
192 +**Function Address:**
199 199  
194 +All the operations for recipe is by this address
195 +
196 +* =0 No operation.
197 +* =1 Read data from recipe.
198 +* =2 Insert a new group or write data to exist group.
199 +* =4 Inserted (only advanced mode).
200 +* =8 Delete.
201 +* =16 Delete and Sequence.
202 +
200 200  **Use Multiple File**
201 201  
202 202  Check it to use more than one recipe file in HMI, but this option only valid in [Advanced mode];
... ... @@ -241,8 +241,27 @@
241 241  **✎Note: **This function only supported in HMI+, i series, ie series, ig series.
242 242  )))
243 243  
244 -**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]
247 +**Operating Procedures**
245 245  
249 +* Click "Project"→"Bit Alarm" as below shows.
250 +
251 +(% style="text-align:center" %)
252 +[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]]
253 +
254 +* Click "Add" button to open "Recipe" setting window.
255 +
256 +(% style="text-align:center" %)
257 +[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]]
258 +
259 +* Set basic settings for recipe.
260 +* Select mode according to actual condition.
261 +* Other settings can be set according to the actual situation.
262 +* Click "OK“ button to complete settings.
263 +
264 +**Recipe Demo Download Link**
265 +
266 +[[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]
267 +
246 246  = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) =
247 247  
248 248  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
... ... @@ -399,7 +399,7 @@
399 399  
400 400  Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen.
401 401  
402 -Recipe function settings will be display in "[[History XY Plot>>path:https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object.
424 +Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object.
403 403  
404 404  (% style="text-align:center" %)
405 405  [[image:历史XY 2.png||class="img-thumbnail"]]
... ... @@ -560,8 +560,15 @@
560 560  * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ".
561 561  * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled.
562 562  
563 -You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]"
585 +You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]"
564 564  
587 +(% class="wikigeneratedid" id="H" %)
588 +**PI Data Record Demo Download**
589 +
590 +**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]**
591 +
592 +**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]**
593 +
565 565  = **User permission** =
566 566  
567 567  **Introduction**
... ... @@ -609,7 +609,7 @@
609 609  1. Check the "User Permission";
610 610  1. Select "Level" to set permission level;
611 611  1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded;
612 -1. Select the "Access Denied Setting" mode;
641 +1. Select the "[[Access Denied Setting>>path:#_Security]]" mode;
613 613  
614 614  **Log information description**
615 615  
image-20220805170000-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 KB
Content
image-20220805170046-2.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -34.5 KB
Content
image-20220805170102-3.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
image-20220805170147-4.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
image-20220805170232-5.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content