180 180  
181 181  * **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object);
182 182  ** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters;
183 -* **Group: **Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places.
183 +* **Group: **It sets the groups' initial number of recipe;
184 184  * **Elements:** It sets members' initial number of each group;
185 185  * **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form;
186 186  * **Decimal: **It sets integer and scale digits;
187 187  
188 -**Mode Selection: **Select Simple or Advanced mode. Recipe file is divided into simple mode and advanced mode. Only in advanced mode can exist multiple recipe files used at the same time. (used wiht file list onject), Simple mode can only support a recipe file; Aadvanced mode can insert group information and reordered.
188 +**Mode Selection**
189 189  
190 -Function address: all operations are done through function addresses, different operating value is as follows:
190 +Users could select Simple or Advanced mode.
191 191  
192 -* = 0: no operation;
193 -* = 1: trigger read data;
194 -* = 2: new trigger or update (If there is group number, it updates.)
195 -* = 4: insert (only valid in advanced mode)
196 -* = 8: delete (Delete according to the writing group number. If write and read address are consistent, refer to the reading group number);
197 -* = 16: delete and sorted ((Delete according to the writing group number. If write and read address are consistent, refer to the reading group number)
198 -* = 64: import CSV recipe file.
192 +**Function Address:**
199 199  
194 +All the operations for recipe is by this address
195 +
196 +* =0 No operation.
197 +* =1 Read data from recipe.
198 +* =2 Insert a new group or write data to exist group.
199 +* =4 Inserted (only advanced mode).
200 +* =8 Delete.
201 +* =16 Delete and Sequence.
202 +
200 200  **Use Multiple File**
201 201  
202 202  Check it to use more than one recipe file in HMI, but this option only valid in [Advanced mode];
... ... @@ -241,8 +241,27 @@
241 241  **✎Note: **This function only supported in HMI+, i series, ie series, ig series.
242 242  )))
243 243  
244 -**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]
247 +**Operating Procedures**
245 245  
249 +* Click "Project"→"Bit Alarm" as below shows.
250 +
251 +(% style="text-align:center" %)
252 +[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]]
253 +
254 +* Click "Add" button to open "Recipe" setting window.
255 +
256 +(% style="text-align:center" %)
257 +[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]]
258 +
259 +* Set basic settings for recipe.
260 +* Select mode according to actual condition.
261 +* Other settings can be set according to the actual situation.
262 +* Click "OK“ button to complete settings.
263 +
264 +**Recipe Demo Download Link**
265 +
266 +[[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]
267 +
246 246  = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) =
247 247  
248 248  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
image-20220805170000-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 KB
Content
image-20220805170046-2.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -34.5 KB
Content
image-20220805170102-3.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
image-20220805170147-4.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
image-20220805170232-5.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content