Changes for page Siemens

Last modified by Joe on 2026/04/01 15:32

From version 2.1
edited by Joe
on 2025/09/09 14:36
Change comment: There is no comment for this version
To version 6.1
edited by Joe
on 2026/04/01 15:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -235,7 +235,7 @@
235 235  
236 236  o: digit address
237 237  )))
238 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
238 +|(% colspan="1" rowspan="9" %)Word|M|MB|MB d|d:0-99999|
239 239  |M|MW|MW d|d:0-99999|(((
240 240  MW0=MB(0~~1)
241 241  
... ... @@ -283,7 +283,20 @@
283 283  
284 284  Address value is a multiple of 4
285 285  )))
286 +|DB0.DB-DB99.DB|DBxDBS|DBxDBSnndddd|(((
287 +nn:0-9999
286 286  
289 +dddd:0-9999
290 +)))|(((
291 +nn:DB No.
292 +
293 +dddd:address value
294 +
295 +Address value is a multiple of 2
296 +
297 +(The data type is for String)
298 +)))
299 +
287 287  **Communication Settings**
288 288  
289 289  Enable HMI Ethernet in [Project Settings];
... ... @@ -318,7 +318,7 @@
318 318  **Such as:**
319 319  
320 320  * DBxDBB20000 = DB2.DBB0
321 -* DBxDBW20004 = DB2.DBW4
334 +* DBxDBW20002 = DB2.DBW2
322 322  
323 323  {{id name="I12.PLCProtocol_html_87ceaea84d552e62.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png||alt="12.PLC Protocol_html_87ceaea84d552e62.png" height="245" width="537"]]
324 324  
... ... @@ -555,6 +555,11 @@
555 555  * VD address should be multiple of 4, because it occupies two VW addresses, such as VD0, VD4, VD8...
556 556  * Written value of RTC cannot exceed 255.
557 557  
571 +(% class="box infomessage" %)
572 +(((
573 +Note: HSW10118 and HSW10119 are supported in HMI V1.0 system. HSW1200 and HSW1201 are supported in HMI V2.0 system.
574 +)))
575 +
558 558  **Cable Wiring**
559 559  
560 560  {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-6"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
... ... @@ -639,18 +639,18 @@
639 639  (% style="text-align:center" %)
640 640  [[image:2.3.2.png]]
641 641  
642 -**PLC Settings(STEP 7-MicroWIN SMART)**
660 +**PLC Settings**
643 643  
644 -Open STEP 7-MicroWIN SMART, create a new PLC project or open the project that has been created.
645 -Create new project:Double click[CPU SR20]→[System Block]→[Module] CPU SR20(AC/DC/Relay)→[OK].
662 +**Select "Set PG/PC Interface" in Communication of the View list and Set PG/PC Interface.**
646 646  
664 +**Select PC/PPI cable PPI.1 and set communication parameters.**
665 +
647 647  (% style="text-align:center" %)
648 -[[image:1.2.png]]
667 +[[image:11.png]]
649 649  
650 -PLC Default Parameters: Double click[CPU SR20]→[System Block]→[RS485 Port]→[Address]2,[Baud Rate]9.6Kbps→[OK]
651 651  
652 652  (% style="text-align:center" %)
653 -[[image:1.3.png]]
671 +[[image:12.png]]
654 654  
655 655  **Cable Wiring**
656 656  
11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +266.0 KB
Content
12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +31.2 KB
Content